KBLS19KTMS3 KitchenAid Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refrigerator was not cold.
Refrigerator was not cold.
I had this problem before and it was the control vale in the back of the refrigerator. I ordered it and change that out in 5 minutes. That wasn’t the problem. I had the repairman come over and within 5 minutes he told me what the problem was. He showed me where the control board was. He then walked me through the removal process.
First remove the light cover on the Freezer & Refrigerator in front where the light button is located. Pull down on the front of the light cover. It pops out.
Second, in the front of the freezer & refrigerator temp control panel put your fingertips in front of the panel and pull down it’s hard to get the pins to release but the front pins will release, then pull down a little to allow the back hooks to release. (You can use a small common screwdriver if you can’t get it with your fingertips).
Next, once the panel is removed then disconnect the wiring harness. Then bring the panel to the counter, this is where you remove the circuit card and replace it. There are 4 hooks that hold the circuit board in place. Use a small common screwdriver to push the hooks away from the board. The new board comes as one piece. The board is perforated to allow you to snap the board. Directions come with the board and how to snap it. You will need to pay attention on how you removed the board. You will need to put the new board in the same way it came out.
Once the board is re-installed and lock into position reverse the process and install the control panel back into position.
Next is the programing of the board. Follow the directions that come with the control board and you will be back in business
This task took about 15 minutes to remove & replace and to program.
I had this problem before and it was the control vale in the back of the refrigerator. I ordered it and change that out in 5 minutes. That wasn’t the problem. I had the repairman come over and within 5 minutes he told me what the problem was. He showed me where the control board was. He then walked me through the removal process.
First remove the light cover on the Freezer & Refrigerator in front where the light button is located. Pull down on the front of the light cover. It pops out.
Second, in the front of the freezer & refrigerator temp control panel put your fingertips in front of the panel and pull down it’s hard to get the pins to release but the front pins will release, then pull down a little to allow the back hooks to release. (You can use a small common screwdriver if you can’t get it with your fingertips).
Next, once the panel is removed then disconnect the wiring harness. Then bring the panel to the counter, this is where you remove the circuit card and replace it. There are 4 hooks that hold the circuit board in place. Use a small common screwdriver to push the hooks away from the board. The new board comes as one piece. The board is perforated to allow you to snap the board. Directions come with the board and how to snap it. You will need to pay attention on how you removed the board. You will need to put the new board in the same way it came out.
Once the board is re-installed and lock into position reverse the process and install the control panel back into position.
Next is the programing of the board. Follow the directions that come with the control board and you will be back in business
This task took about 15 minutes to remove & replace and to program.
Parts Used:
-
Edward from Reading, AL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy, running constantly motor in damper unit.
Unsnapped and pulled off small cover exsposing two phillips head screws. I removed larger cover and styrofoam insert fully exsposing the damper unit. i unplugged same and with a 1/2 inch wood chisel was able to release the "snaps" holding the old unit in place. Simply reverse procedure to install new unit.
Parts Used:
-
lawrence from TRAVERSE CITY, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
About twicw per year the freezer would ice up because the control board didn't activate the defrost element
Removed the cover using a mirror to see how to release the clips on the rear side of the cover, removed the circuit board noting how everything was installed and also visually verified the part was the same. Broke the circuit at the designated score, installed and followed instructions for programming. All is well now.
Parts Used:
-
Larry from GOLDEN, CO
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old glass broke , new glass fit perfect
-
Jacob from SHEBOYGAN, WI
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ladder hook for shelves broke.
-
Helene from Matawan, NJ
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken center crisper rail
Lift off glass shelf and insert tabs of rail on each end , replace shelf.
Parts Used:
-
Neil from WILMINGTON, MA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced left side guide on the freezer basket drawer.
Removed Phillips head screw on the front cover of both guides. Pull the drawer forward until it stops. Snap up the cover on each geared wheel to allow the basket to lift enough to continue removing the basket.
Swing the front of the guide rail towards the back which allows for the rear tab to come out of its hole.
Put new guide back in following reverse order.
Done!!
Swing the front of the guide rail towards the back which allows for the rear tab to come out of its hole.
Put new guide back in following reverse order.
Done!!
Parts Used:
-
Raymond from GLOUCESTER PT, VA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had no problem
Just take the crisper out and just put it in the hall access
Parts Used:
-
DIANE from WEST PALM BCH, FL
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and refridgerator just stopped working.
The Condenser Fan Motor was already removed due to searching for the problem. The new fan motor looked different from the original but I felt very comfortable that Part Select had sent me the new part showing original part number changing numbers over the years. Simply placed the fan blades onto the new motor lined up 2 of the holes placed screws and tightened then plugged the wire ribbon into the Condensor Fan Motor, plugged in the Refridgerator and it worked beautifully.
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
Parts Used:
-
Daniel F from CALEDONIA, MN
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Our old plastic dairy door had a broken part and it kept coming undone
The new door just popped into place. Took seconds to complete. Fast delivery too.
Parts Used:
-
Mark from DEARBORN, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The control indicators would flash and buzzing noise came from the controler
Followed the video exactly as shown from the website. I do suggest using a mirror or your phone to visualize the notch to press to drop the cover.
Parts Used:
-
John from JACKSON, MS
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Difficulty removing old switch.
Everything went as planned except the cold temperature (freezer door switch located inside freezer) made deflection of the switch locking tab difficult to remove. Letting the switch warm up was not an option.
Parts Used:
-
Ronald from HUNTINGTN BCH, CA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would not defrost
I checked the element and the thermostat and determined the problem to be the control board. I simply followed the instruction in the video. Everything went well until the last step, the video said to push the freezer down button. When this did not work I refered to the written instructions which told me to push the up button. That did it. Job complete. The unit is working as it should.
Parts Used:
-
William from FAIRFIELD, VA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge was leaking water because of bad drain
Switched the drain out using the video tutorial
Fixed the problem
Have had no more drain issues
Fixed the problem
Have had no more drain issues
Parts Used:
-
David from NEWTON, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower freezer section was icing up, not defrosting properly. Repeated manual defrosting including disassembling did not solve the problem.
Emptied and disassembled the freezer. Defrosted and dried the coils. Tested the defrost heater coil ( 50 ohms ) PRT and fan - all OK. Opened the lower back panel and cleaned the water collection tray. Vacuumed out all debris including coils underneath. Reassembled everything. Removed the old control board and installed the new board paying attention to ESD steps. Applied AC power. Programmed the new board per the video link ( nicely done ). 3 weeks later and the unit seems dry and happy. Running at lower settings with good temperature results. Suspect the 24VDC relay activating the defrost heater coil on the control board or what controls the relay not working. May pull relay for test.
Parts Used:
-
Robert from Meridian, ID
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!