This ceramic microwave fuse is just over an inch in length. It is white in the center, and metal on both ends. This is a 20-amp fuse, and is used to power your microwave. If the touch pad on the micro...
If your microwave won’t start even though the door is shut, this switch might be the reason. It helps your microwave know the door is closed so it can run safely. This genuine part is easy to install ...
This replacement microwave grease filter features multiple layers of aluminum that work together to capture grease and minimize odors. By preventing debris from entering the recirculation system, it h...
This diode cable is a replacement electrical component designed to regulate current flow within an appliance circuit. It helps protect sensitive components and is commonly replaced when electrical fau...
This is the replacement damper bracket for your microwave. It is made of plastic and is approximately 11 inches wide and 3 inches long. The damper bracket attaches to the outer cabinet and directs air...
This vent damper is a manufacturer-approved replacement part for your above-range microwave. This part helps vent air from the microwave to the exterior of your home, and helps keep exterior wind out ...
This capacitor delivers the electrical boost required for motors to start and operate efficiently. Proper capacitance reduces strain on motor components and helps prevent startup failures or inconsist...
$72.93
Special Order
Questions And Answers for JVM1640CJ03
Ask our experts a question about this model and we'll get back to you as soon as possible!
3 questions answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
James
February 8, 2020
What cubic foot is this micro-wave?
For model number JVM1640CJ03
Hello James,
Thank you for your question. Your model JVM1640CJ03 has 1.6 cu ft for its total capacity. We hope this helps.
3 peoplefound this helpful.
Was this helpful?
Thank you for voting!
Bernsrd
October 30, 2023
What are the exterior dimensions?
For model number JVM1640CJ03
Hello Bernsrd, thank you for your inquiry. The exterior dimensions of your model are: 16 3/16 H x 29 7/8 W x 15 5/32 D. We hope this information helps!
1 personfound this helpful.
Was this helpful?
Thank you for voting!
Shayne
September 29, 2025
Its arching from inside on the right and its clean not sure what could be but maybe magnatron
For model number JVM1640CJ03
Hello Shayne, thank you for getting in touch. Your microwave is arcing because of a damaged waveguide cover, part number PS2321139, which is a mica-like sheet on the right side of the cavity that protects the magnetron. Replace it to fix the issue. We hope this helps.
Turned out the issue was easily solved by replacing a single, inexpensive fuse.
First off, UNPLUG THE MICROWAVE.
The fuse is located under the plastic grill at the top of the microwave. It's held on by two screws. Once you've removed the screws and taken off the plastic grill, you go to the right side of the microwave and remove another screw that holds a small metal grill in place. Removing the small metal grill is probably the toughest part of this repair. You kind of have to rock it back and forth a bit to get it to release. Once that's off, you can get to the fuse. I removed the burnt out one with a pair of needle nose pliers. I also put a small piece of cardboard under the fuse when I did this so I didn't accidentally drop it into the innards of the microwave. I did the same thing when I replaced the new fuse. I then plugged the appliance back in and made sure it worked. Once that was confirmed, I replaced both grills.
Unpluged power cord!! Removed front control panel to expose electronics (need to remove top horizontal vent cover to expose mounting hardware). Unplugged leads to control panel board. Removed magnetron with Tstat (3- phillip heads, need stubby). Installed new parts and control panel, plugged it in tested. Done.