Refrigerator light wouldn't come on.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
Parts Used:
-
Daniel from Crown Point, IN
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Does not start , trips breaker
I pried the relay from compressor with small screwdriver, cut and replaced burnt wire going to relay,pushed new relay on compressor and wires unfortunately it did not fix the problem.
Parts Used:
-
Paul from RNCHO CORDOVA, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Deli drawer broke off, probably loaded to heavy
Removed the divided glass shelf, to which the slide rail is attached. Removed the broken rail, saved the two screws.
Now comes the clincher:
It would help if the replacement part website would tell you what size and what kind screwdriver you will need, so you could start chasing it while you wait for the part.
Even better if they could include it, since the plastic part and it‘s shipment is not exactly cheap.
So to screw in two screws you need a #15 Star screwdriver!
How many housewife’s have this one in the tool drawer?
Now comes the clincher:
It would help if the replacement part website would tell you what size and what kind screwdriver you will need, so you could start chasing it while you wait for the part.
Even better if they could include it, since the plastic part and it‘s shipment is not exactly cheap.
So to screw in two screws you need a #15 Star screwdriver!
How many housewife’s have this one in the tool drawer?
Parts Used:
-
esther from PELHAM, NY
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Parts Used:
-
Robert from Coto de Caza, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The original fan had its blades sheared by ice build-up
The original design is poor. The evaporator fan is mounted in an upright position just below the ice-maker. A plastic grate mounts over the fan assembly to allow for air circulation. Unfortunately, random chips of ice from the ice maker can fall into the fan, causing the fan to shear its blades. Replacement of the fan blade is relatively simple (accept for having to completely unload the freezer and remove all back covers, the ice-maker auger motor assembly, and the metal evaporator cover). In order to mimimze this from reoccuring, I installed a 1/4'' mesh metal screen over the exhaust ports on the cover. Thus far, this has worked well to keep ice chips out of the evaporator fan.
Parts Used:
-
Jeffrey from Broomfield, CO
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Wrench set
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Parts Used:
-
randall from coopersville, MI
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
Parts Used:
-
charles from SCOTTSDALE, AZ
-
Difficulty Level:Very Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser icing refrigerator warm freezer ok
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
Parts Used:
-
Rene from HEBER, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ref was not freezing correctly
took back cover off. swept the rear with a vacuum cleaner to get rid of dust.found that the fan would not turn. ordered part with your really great ordering technique. Part was suppose to be here in 3-5 days and was here the next day!!!.Removed 2 bolts pulled out the plastic clip that held the wire on. and worked the fan blade off shaft. removed and replaced in the same order as taking simple Thanks
Parts Used:
-
Desiree from Greensburg, PA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
4 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condensor fan blade cracked, blade was sheared off.
First, remove the cardboard cover on the back, lower portion of the refrigerator.
Next, locate the condensor fan motor assembly and blade. (Right side as you are facing)
Using a pliers, hold the shaft to keep it from turning and prevent damage to the motor. Using a screwdriver, slide the old ring compression on the blade shaft toward the motor (away from the fan blades) to loosen.
Remove old blade from the shaft by firmly grasping the motor shaft with a pliers (to prevent from damaging) and pull the blade assembly off.
Reverse the above steps to attach the new blade.
Next, locate the condensor fan motor assembly and blade. (Right side as you are facing)
Using a pliers, hold the shaft to keep it from turning and prevent damage to the motor. Using a screwdriver, slide the old ring compression on the blade shaft toward the motor (away from the fan blades) to loosen.
Remove old blade from the shaft by firmly grasping the motor shaft with a pliers (to prevent from damaging) and pull the blade assembly off.
Reverse the above steps to attach the new blade.
Parts Used:
-
Bradley from Cedarburg, WI
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not getting a tight seal
I simply removed the old seal on the refrigerator door and replaced it by just pushing the new gasket seal back into place. It was a very easy repair to do.
Parts Used:
-
JOSEPH from WARMINSTER, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
old gasket was stretched and broken. Bad seal
It was a snap! Literally. We just pulled out the old one, cleaned the track and snapped in the new one
Parts Used:
-
Carol from Seminole, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Parts Used:
-
Eileen from Coto de Caza, CA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers
5 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squeky Evaporator Fan
-
Douglas from LAFAYETTE, LA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My fridge kept making a high pitched noise towards the bottom back. The food had also started thawing out.
I followed the instructions provided on the video emailed to me. I had some trouble only because my refrigerator was slightly different and it was hard to get the old condenser fan motor out. Other than that I was super pleased to have found Partselect.com. There is no way I would have been able to tackle such a major job without their step-by-step detailed help. I am enormously grateful to them. They shipped my parts the next day which is evidence of their sincere concern and understanding of the urgency of my problem. I can surely say they saved me many hundreds of dollars!
Parts Used:
-
Liz from LOS ANGELES, CA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers, Socket set, Wrench (Adjustable)
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!