Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.
Other than the two-screw problem, it was easy.
Other than the two-screw problem, it was easy.
Parts Used:
-
Joe from Brentwood, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
37 of 49 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
Parts Used:
-
Michael from Milton, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
32 of 34 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Parts Used:
-
Steven from Cave Creek, AZ
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
41 of 62 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Parts Used:
-
John from Lodi, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
33 of 42 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Parts Used:
-
Joe from Suffolk, VA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
30 of 34 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water continued to flow after icemaker was full
Using nutdriver removed access panel on back. Unscrewed water supply line. Using nutdriver removed water inlet valve. The feed line to the icemaker is a pushlock connection so removed feed line. Then reverse process.
Parts Used:
-
Ray from Salem, AR
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
32 of 49 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Parts Used:
-
GARY from PARRISH, FL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Wrench set
35 of 62 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Parts Used:
-
John from Windham, NH
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers, Socket set
23 of 29 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice built up on coils. Fridge was warm.
No instructions came with new parts. Access to element was impossible until I accidentally discovered that the two styrofoam cushions at the ends of the coils were removable. Once removed, access to the heater and thermostat was very easy.
Unplug appliance, remove freezer shelf, cold air ducts, back of freezer, disconnect light, (My model does not have ice maker. This may also need to be disconnected.)
1.Remove styrofoam cushions at end of coils
2.Locate element between bottom two coils
3.Disconnect the male/female connections
4.Remove support clip under center of element
5.Remove element
6.Replace new element in reverse
Connecting the thermostat wires was challenging because they were somewhat behind the coils.
1.With styrofoam removed, unclip thermostat from coil
2.Carefully cut wires (leave enough to connect new wires)
3.Connect new thermostat wires (color of wires matched on my fridge)
4.Clip new thermostat in place
5.Replace styrofoam
6.Button it all up
With these steps, this job would take maybe 30 minutes; somewhat longer if your model has an icemaker.
Hope this helps.
Unplug appliance, remove freezer shelf, cold air ducts, back of freezer, disconnect light, (My model does not have ice maker. This may also need to be disconnected.)
1.Remove styrofoam cushions at end of coils
2.Locate element between bottom two coils
3.Disconnect the male/female connections
4.Remove support clip under center of element
5.Remove element
6.Replace new element in reverse
Connecting the thermostat wires was challenging because they were somewhat behind the coils.
1.With styrofoam removed, unclip thermostat from coil
2.Carefully cut wires (leave enough to connect new wires)
3.Connect new thermostat wires (color of wires matched on my fridge)
4.Clip new thermostat in place
5.Replace styrofoam
6.Button it all up
With these steps, this job would take maybe 30 minutes; somewhat longer if your model has an icemaker.
Hope this helps.
Parts Used:
-
Neil from Boise, ID
-
Difficulty Level:Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Pliers
21 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan To Cool Condenser Not Working
1. Unplugged the refrigerator 2. Vacuum inside of dust 3. Unscrewed motor and fan 4. Replaced motor then fan 5. Plugged refrigerator bingo! :)
Parts Used:
-
Wilbert from Fort Lauderdale, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
19 of 22 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Parts Used:
-
Gary from Glendale, AZ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
21 of 28 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Parts Used:
-
Tracy from Yuba City, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
18 of 23 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor vibration
I pulled the inside cover in the freezer off, pulled the motor out of the bracket, replaced the fan blade , motor, and grommet and that was pretty much it. Very easy to replace. Parts select was fast and had the cheapest price available.
Thanks
Steven Roffey
Thanks
Steven Roffey
Parts Used:
-
Steven from Columbus, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
18 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice bucket missing
I discovered the ice bucket missing from my rental unit at the beach. I was able to go online with my Blackberry, easily navigate your website using the model number to look up the part information , order it, and have it in place for the next renter.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
Parts Used:
-
Tom from Bradenton, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
14 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor stopped turning
1. Unplugged the fridge. 2. unplugged the fan connection and removed the wire holding clip. 3. removed the 2 screws holding the motor bracket in place and removed the bracket. 4. Pulled gently back on the motor so that the fan pressed against the front bracket until the fan slid off the motor shaft. 5. Pulled the rubber motor mounts off of the old motor and placed on the new motor. 6. Slide the new motor in place pressed the fan all the way onto the shaft. 7. Placed the rear motor bracket in place and started the screws by hand making sure the ground wire was attached to the furthest away screw. 8. tightened the screws down. 9. Pushed in the wire holding clip into the clip hole. 10. Plugged back in the fan. 11. Plugged back in the fridge. 12. Turned down the temp on the fridge to kick on the compressor and checked to assure the fan was operating and then set the temp back to normal. 13. Vacuumed the condenser coils to get them all clean and ready for more years of service!
Parts Used:
-
Arthur from Alamosa, CO
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Socket set
14 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!