Icemaker Wasnt Making Ice
After unplugging electric cord and turning off water at wall, I then removed the two screws that secured the valve to the refrigerator. I then removed the water connections to the valve and removed a short portion of the hose going to the icemaker. I then installed the connection pieces provided package and reversed the procedures to install the new part. It was easier than I thought it would be.
Parts Used:
Single Outler Water Valve Kit
  • ERIC from SAN ANTONIO, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan Noise
took cover off inside freezer control . removed old fan and unpluged wire harness plugged new one up and fastened back in place and put control cover back on.
Parts Used:
Evaporator Fan Motor Kit
  • Kenneth from Springfield,, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and then attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
Parts Used:
Evaporator Fan Motor Kit
  • alonso from Compton, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the evaporator fan stopped working
I removed the plastic cowl in the rear of the freezer to gain access to the fan, took out two screws that secured the brackets holding the fan. Then I separated the coupling wires which had a sort of locking mechanism that was simple to undue. I took out the brackets along with the fan, separated the brackets and removed the screw for the ground wire. Then I simply reversed the process.
Parts Used:
Evaporator Fan Motor Kit
  • Stephen from Bloomfield, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thought the evaporator fan was the issue
Did the obvious. Removed the stick-out cover, then the back of the freezer wall, after taking the bad evaporator fan out. Replaced the old motor with the new one, stuck the fan blades back on, and put the replacement back in place. Checked to see that the new motor and fan, before final hook up, had no issues. That was a success. However, when I put the parts in place, I had some significant vibrations. By taking things apart and re-doing the install, the vibrations went away. However, the final install, even if quiet, did not work. Apparently the condenser was kaput. No cooling after all the adjustments. We gave up and are replacing the fridge.
Parts Used:
Evaporator Fan Motor Kit
  • Dale from Fort Myers, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan motor worn out
Removed the old and installed the new. Electrical plug/socket made connection easy. Biggest problem is working space in freezer side of a side by side with the fan in the back. If I can do it anyone can.
Parts Used:
Evaporator Fan Motor Kit
  • Richard from Norman, OK
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker did not work.
I pulled the cover from back of fridge then removed two screws from the water valve disconected the wires and removed water lines. had to reroute water lines so the universal part would fit. don't forget to turn off the water befor doing the above. found new mounting hole and reconected water lines. worked like a champ.
Parts Used:
Single Outler Water Valve Kit
  • LARRY from HANOVER, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the evaporator fan quit when we had a power surge
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.
Parts Used:
Evaporator Fan Motor Kit
  • Darrell from Bentley, ND
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor squeal
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
Parts Used:
Evaporator Fan Motor Kit
  • Mark from Partlow, VA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water was not pumping up to the ice maker
It was very easy. Took off water line and two screws. Put new valve back on and presto life (ice) is good again.
Parts Used:
Single Outler Water Valve Kit
  • randy from brown deer, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The original fan motor began masking a noise and finally stoped working.
Followed video instruction and completed the replacement. I had to join the wires since the connector was a male plug to a make plug.
Parts Used:
Evaporator Fan Motor Kit
  • Justin from FRANKLIN, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
Parts Used:
Evaporator Fan Motor Kit
  • Jerry from PHOENIX, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit making cubes, instead it made a large block of ice.
Unplugged the fridge. Removed water inlet valve from fridge. Used voltmeter to test for resistance (between 50 and 150 ohms). Didn't pass the test.
My original part was 218720400. I ordered part PS468507 from partselect.com. My original part had a "garden hose" coupling so PS468507 fit the bill.
This part's electrical connection wasn't angled the same way as the original so we had to finagle it.
Hooked the plastic refridgerator supply hose up first.
Then screwed on the copper "garden hose" connection to the valve using channel lock pliers. Was careful not to over tighten.
Then the fun started. The electrical connector wires were a tight fit between the copper tubing and the refridgerator frame. Did I mention that the electrical connetion wasn't angled the same as the original? My daughter got her smaller hands in there and was able to make the connection.
NOTE: Because of the angling issue I was unable to screw the anchor plate to the fridge.
I made sure that the valve did not interfere with the fan.
Turned on the water and checked for leaks.
Plugged the fridge back in and in a couple of hours we had ice cubes. Works like a charm!
Parts Used:
Single Outler Water Valve Kit
  • Fred from Belton, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light wouldn't turn on when door opened
Unplugged fridge, opened the door, used flat head screwdriver to pop off old switch, unplugged wires, plugged in new switch, popped it back in, and plugged the fridge back in. 2 minute fix.
Parts Used:
Light Switch
  • Matthew from SOUTH BEND, IN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Make Stopped Making Ice
It was very easy. Pulled off the old valve and replaced with the new one and it started making ice right away. There are a couple of issues you need to be aware of that I am watching closely now. The old valve was a 15 watt valve. The one they sent me is a 35 watt valve. It really pressures the water into the ice maker. So much so I am getting a little leaking from the overflow. Its working so well and powering the water in so fast it starts to leak a little due to being to full. When I ordered the part, no where did it show the wattage of the valve so be careful. It works great but will have to keep an eye on it so it does not overflow.
Parts Used:
Single Outler Water Valve Kit
  • Jeff from Sunrise, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 7 people found this instruction helpful.