Freezer running, yet fridge warm.
The fridge went warm and I noticed ice build-up on the freezer floor underneath the coils. I mistakenly thought that the defrost heater (or thermostat or timer) must have been the culprit. I used a voltmeter to test those components and chased a wild goose for quite sometime before realizing that the evaporator fan was not spinning and that it failed a test with the voltmeter. Replacing the fan easily fixed my problem! I later realized that the sheet of ice on the freezer floor indicated that the defrost cycle had been working. Were that not the case, the ice would have been all over the coils.
Parts Used:
Freezer Evaporator Fan Motor
  • Skyler from San Marcos, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers