ABB1921BRM03 Whirlpool Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The frost free drain behind the freezer compartment clogged and water collected in the bottom of the freezer and eventually came out the door on the right front of the refrigerator.
The other instructions and the video provided by Parts Direct are pretty good with instructions, but they omit two steps. First, if you have an ice maker, you will need to unplug the connector on the back side of the panel you remove at the back of the refrigerator to access the drain tube. Just unplug it and you can move the removed panel to the side without disconnecting any of the water lines. Second, the instructions say to just reconnect the "bottom end" of the new p-trap drain to the drain pan at the bottom of the refrigerator. They don't tell you there are two places to connect the new p-trap to the drain pan. The original tube/trough connected to the one at the back of the drain pan on the left (viewed from the rear of the refrigerator). At first, it looks like the new p-trap won't reach to it for the connection, but if you look closer, there is another connector to the right of the original one that the p-trap connects to properly. Replacing the drain trough with the new p-trap was actually pretty easy and would only take about a half hour. Add another half hour to give the refrigerator coils a good cleaning as they will need it now that you can reach them. The real time consumer, 3 to 4 hours, is needed to use a hair dryer to melt and clear the ice from the condenser at the back of the freezer so the water can drain. Just take your time and all the ice will eventually melt and drain out so the new p-trap will work properly.
Parts Used:
-
David from ROSEBURG, OR
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
8 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Glass shelf had shattered and needed replaced
The repair was just unpacking the glass and placing it on the frame inside the refrigerator. Unfortunately, the shelf was listed by photo and not dimensions for the model number submitted and is approximately 2 inches short. Had I known the dimensions ahead of time, I would not have placed the order.
Parts Used:
-
Martha from Jacksonville, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
8 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking water onto floor
replaced the poorly designed "duck bill" drain with this P trap. Very simple repair done by accessing through the back of the refrigerator. The video on this website walked me right through the repair. It did however fail to mention that the ice has to be removed from the inside. I had to remove the drawer face and pull outs. Then the ice maker and back panel are removed. I used a heat gun and screwdriver to chip and melt the ice build up. If one had the luxury of having another refrigerator to move food in to you could just unplug the unit until the ice melts.
Parts Used:
-
Mark from ALTO, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Parts Used:
-
Michael from East Meadow, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would cool for a very short period of time. Then the compressor would shutdown via internal thermal overload or high head pressure. This was caused by the lack of airflow across the condenser coils and compressor.
(1) Slide out appliance and remove power source. (2) Removed lower access cover on rear of refrigerator. (3) Disconnected plug to the condenser fan motor. (4) remove blades by pulling gently forward (5) remove mounting hardware holding the fan motor (3 screws) (6) motor is now free and new motor can be installed
Parts Used:
-
Daniel from RICHTON, MS
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers
10 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer temperature goes down to -20*F before compressor stops but refrigerator side remains normal 38*F and compressor makes a grunting noise while running.
Unplug ref then remove lower(freezer) panel plus trays and thermistor’s cover/holder then remove the evaps cover. I found the evaps all frozen up. Cut and remove old thermistor, strip wires 1/2 inch then cut the new thermistor wires to length and strip 1/2 inch, use the enclosed insulated crimp type connector and put back everything in the reverse order. It works great afterwards.
Parts Used:
-
Aquilino O from VALLEJO, CA
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Parts Used:
-
Antonio from San Antonio, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
7 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Freezer worked fine, but upper refrigerator would not cool.
I first replaced the lower (freezer) evaporator thermistor based on recommendation from other feedback, however that did nothing to resolve the problem. I subsequently discovered a diagnostic document hidden under the upper right door hinge, which helped me narrow the problem down to the upper (refrigerator) evaporator fan motor. After replacing the fan motor, my refrigerator is up and running again. The only challenge was accessing and removing the access panel(s) and air column. Once those were removed, replacing the fan motor was simple.
Parts Used:
-
Stephen from Jacksonville, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Nutdriver, Screw drivers
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
-
Duncan from Metairie, LA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
reassembled the pieces.
Parts Used:
-
Dave from Manchester Center, VT
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Parts Used:
-
Terry from WARMINSTER, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thought motor was bad freezer cold fridge hot
Ordered new fan motor
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Parts Used:
-
Wayne from PENNINGTON, NJ
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
Parts Used:
-
Sung-Su from BISMARCK, ND
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the rail to hold the crisper drawers broke
I first removed the bottom shelf. Then I popped the rail in. It was pretty easy although I did have to use some force to fit it in. Ordering the part and doing it myself was a lot cheaper than calling the repair man.
Parts Used:
-
Christina from Orange, CT
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
FREEZER WOULD NOT DEFROST.
I initially tested the heating element and defrost thermostat using an ohm meter. the defrost thermostat was incased in ice, so I replaced it first. The refridgerator worked for about a week and then froze up again. I then replaced the thermistor and the unit is working as designed.
Parts Used:
-
JEFF from SEATTLE, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!