Dryer Radiant Flame Sensor
PartSelect #: PS11741429
Manufacturer #: WP338906
This part senses if the igniter is hot enough to ignite the flame for heat, allowing the gas valve to open. The sensor is three inches long and is used for many gas clothes dryers. If your dryer is no...
$49.45
In Stock
Washer Screw 818 X 1/2
PartSelect #: PS11741443
Manufacturer #: WP3390631
This screw is sold individually.
$9.85
In Stock
Ignitor
PartSelect #: PS11742507
Manufacturer #: WP4392003
This igniter can only be used in place of round style igniters. This part ignites the gas within the dryer.
$55.99
Special Order
Dryer Nut
PartSelect #: PS11748944
Manufacturer #: WPW10139757
Sold individually. This nut is for dryers.
Follow appropriate safety practices when installing the nut.
$10.57
Special Order
Common Symptoms of the 99937EG
[Viewing 1 of 1]Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Gas Flame Would Drop Out
First it was a process of alimination to find out why it was dropping out. After the problem was found it was just a matter of replacing the holding coil on the gas valve. Thank you fred kenney sr
Parts Used:
-
FRED from BRIELLE, NJ
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
49 of 66 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not heat up.
I unplugged the dryer,removed the two small screws on the front of the dryer and pulled the bottom forward. The two wires connected to the door do not have to be removed. With an electrical tester using the Ohm setting I tested the Radiant sensor and the Gas Valve coils. The two terminal coil was DOA. The dryer can be operated with the front open as long as the door wires are connected. Symptons: The igniter would heat up and not release gas. My repair was successfull due to this awesome website and the super fast shipping service. AAAA++++
Parts Used:
-
Roger from Bonners Ferry, ID
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
26 of 30 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dyer would not heat, flame would shut off within 10 seconds
I opened the panel, undid the plugs, detached the radiant sensor by undoing one screw and removed and replaced the part. Fairly simply.
Parts Used:
-
Christy from Riley, MI
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers, Socket set
24 of 29 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!