This 18 ml bottle of white appliance touch-up paint is used to cover scratches or marks on your appliance. The white touch-up paint can be used on refrigerators, microwaves, ranges, clothes dryers, an...
$10.20
In Stock
Order within the next 12 hrs and your part ships today!
This hose attaches to water pump assembly.
NOTE: As per the manufacture if the washer has an Eco Ball, it's no longer needed when the new hose is installed.
$47.84
In Stock
Order within the next 12 hrs and your part ships today!
This hose clamp extends from half an inch to an inch in diameter. It is made entirely of metal and is intended for use with Maytag brand washing machines.
$11.68
In Stock
Order within the next 12 hrs and your part ships today!
This is an actuator switch to trigger bleach, detergent, or fabric softener housings to be dispensed into the tub of your washing machine. If your detergent cups are not dispensing, you may need to re...
$123.16
In Stock
Order within the next 12 hrs and your part ships today!
I removed the 3 screws toward the top of the back of the washer to remove the top. After that, I located the water pressure level switch, slid it out of the slot into which it is secured, removed the narrow black tubing from the bottom of it, and draped the newly-unattached end of the tube so that it would be easy to find. Then I removed the set of wires and discarded the old switch.
Next I attached the wires to the new switch, attached the black tubing and put the switch back into the slot. I tested the washer and it worked. Next, I put the top back on using the 3 screws. That was it!
Removed the top (3-4 screws at back). Flowmeter has 2 hoses with hose clamps. Removed with plyers. Simple electrical connector removed.
Reversed procedure. Running perfect now.
How did I know it was the flow-meter? Read the service manual as possible causes to narrow it down. Disassembled old flowmeter and cleaned. That fixed for awhile. Problem came back, could 'tap' on flowmeter to temporarily fix. This convinced me that was indeed the problem.
The flowmeter is just a simple vane that moves as water flows across it, and sends pulses each time it rotates. If it 'sticks' then the computer doesn't think any water is coming in - hence the error. Tapping on it would 'unstick' long enough to confirm problem.