The new part was too thick for the worn out plastic ring which is obsolete.
Needed to raise the part to match the ring. I used peanut butter to hold plastic shim while replacing to hold it in place. Built in Oct. 2009.
Parts Used:
Turntable Motor Coupler
  • James from PURCELLVILLE, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Shaft socket was worn out
Pop old one out and replaced it with new one.
Parts Used:
Turntable Motor Coupler
  • Cesar from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave operated but did not heat
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Parts Used:
Fuse,Time Delay
  • Donald from Oak Ridge, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
1 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
House wiring failure caused excessive voltage to microwave
Disassembled control panel and checked power transformer windings. Primary winding fried. Patched power to magnatron transformer to make sure it was ok. Removed power transformer and checked diodes and transistors on board which were ok. Installed new transformer and reassembled control panel to microwave. Checked functions.
Parts Used:
TRANSFORMER,POWER
  • Douglas from Missoula, MT
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
Was this instruction helpful to you?