64283 LG - Overview
Models starting with 64283
Click on the best match to narrow your results.
Exact Part matches for your search term
[Viewing 1 of 1]
KNOCKER, K9-102 1.5 W/ CARB
This part number matches the current model number 64283
PartSelect #: PS18712612
Manufacturer #: 64283
No Longer Available
Keep searches simple, eg. "belt" or "pump".
Time Delay Fuse
PartSelect #: PS3522743
Manufacturer #: 3B74133Q
Sold individually.
$13.24
In Stock
Order within the next 7 hrs and your part ships today!
Spring
PartSelect #: PS3524607
Manufacturer #: 4970WRA001G
$17.47
In Stock
Order within the next 7 hrs and your part ships today!
Microwave Micro Switch
PartSelect #: PS3529293
Manufacturer #: 6600W1K001C
$24.73
In Stock
Order within the next 7 hrs and your part ships today!
Turntable Motor Coupler
PartSelect #: PS3522918
Manufacturer #: 4370W1A006B
The turntable motor coupler connects the turntable motor to the tray. If the turntable on your microwave will not rotate, you may have a faulty motor coupler. The coupler commonly has a D shaped openi...
$29.21
In Stock
Order within the next 7 hrs and your part ships today!
Holder Assembly,Locker
PartSelect #: PS3519053
Manufacturer #: 3501W1A019D
Are you struggling with a faulty microwave door? Introducing the Locker Door Latch Housing Assembly, a crucial part specifically crafted for LG microwaves. This essential component guarantees that you...
$55.42
Special Order
High Voltage Diode
PartSelect #: PS3528799
Manufacturer #: 6021W3B001V
$20.24
In Stock
Order within the next 7 hrs and your part ships today!
Common Symptoms of models starting with 64283
[Viewing 5 of 5]No heat
Fixed by
these parts
these parts
Show All
Won’t turn on
Fixed by
these parts
these parts
Show All
Tray won’t turn
Fixed by
these parts
these parts
Show All
Doesn’t shut off
Fixed by
these parts
these parts
Show All
Door not closing properly
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken door micro switch. (unit does not start heating)
Unplug the unit before servicing. Need phillips screwdriver. Open door. Use step ladder to access and remove 2 small screws from top of the room air diffuser at top of unit. Slide diffuser slightly to the left to align the diffuser's plastic tab on the left side to rotate toward you. (The wires for the front control panel are at the far left side of this difuser, but difuser is slotted for easy removal). Once the difuser is removed you will see 1 screw at the top that secures the pannel cover on the left side of the unit. Remove screw and slide this panel slightly up and out. This exposes the plastic frame that holds the upper and lower door switches. To locate the door switches and observe how they work, close and open the door and watch the door (bayonets) open and close the micro switches. Do the (red) buttons on top of the switches move up and down when the door bayonets push and release? If the buttons do not "pop" up when opened the switch is defective. The switch frame is secured with 2 screws. Remove screws and rotate the unit out for easy access to the micro switch(s). The internal (spring?) on my unit that is suposed to allow the red (visible) button on top of the switch to "pop" up when the door is opened was broken. Carefully pry the switch outward while being careful to lift the plastic holder-piece that holds the switch in place. Be careful, there is a small pin on the frame, so rotate the switch OUT toward you while lifting (carefully) the plastic holder-piece (you will see it on top of the switch). You can use an ohm meter to test the continuity of the switches. But if the buttons don't "pop" they are defective. Replace switch and reassemble.
Parts Used:
-
JAMES from BILLINGS, MT
-
Difficulty Level:Very Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
37 of 66 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
One of the switches in a component that door activates when shut.
I replaced the whole component with all three switches in it even though only one switch was bad . Taking out one switch out of the holder unit would probably have damaged the unit that was holding the switches. Easy install and it works great again .
Parts Used:
-
Jimmy from OZARK, MO
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
9 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door sensor switch went bad. Microwave would not operate.
Watched a couple of repair videos on Youtube by searching for the model number. Found out what to do in order not to get shocked by the powerful capacitor.
Ordered the two switches (To be sure, I could have ordered a third switch as suggested in the videos.)
Bought a tamper-proof star bit to get the cover off. Followed the directions to replace the switches. - I broke the harness and had to use some super glue, but it's all good. I should have removed the harness instead of trying to get a switch out while it was still in place.
It's all back together, and the wife is happy!!
Ordered the two switches (To be sure, I could have ordered a third switch as suggested in the videos.)
Bought a tamper-proof star bit to get the cover off. Followed the directions to replace the switches. - I broke the harness and had to use some super glue, but it's all good. I should have removed the harness instead of trying to get a switch out while it was still in place.
It's all back together, and the wife is happy!!
Parts Used:
-
Randall from ARCADIA, CA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers
15 of 29 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!