36369662991 Kenmore Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
light switch freezer door
put the gratefruit knife behind the old switch pooped it out pluged the new one in piece of cake 5min.even vacumed the dust off the coil
Parts Used:
-
Sumlorq from Cleveland, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
3 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge light dead even with new bulb
1- youtubed the potential diagnoses, 2- resourced and ordered parts, 3- removed old socket, installed new one :-)... My fridge is an older fridge and could've used a screwdriver for eyeglasses. Plug and play easy... YAY!
Parts Used:
-
marj from NEWBURY PARK, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaking from under dishwasher
Water was leaking from under the GE dishwasher, but once we pulled it out, had apparently been going on for a little while. Turning the water off to the dishwasher made it stop, so it was happening even when the unit was not running, potentially indicating somewhere early in the path of the water to and into the machine.
Indeed, inspecting the water inlet vale showed a slow leak. Getting the replacement part was fine, and it fit the electrical, water inlet (existing 90-degree water inlet elbow), and water outlet connections just fine - but the original machine screws that held on the original water inlet valve did not work. It took a little research to figure out the new type of screw required, which was apparently a 10/16 Type AB, which seemed to be a less common type of sheet metal screw (with a point), as opposed to the original flat-ended machine screws. So, after ordering those separately (which were a bit expensive), it went together fine.
A note on the water inlet valve part just indicating the the threading on those parts has changed over time, so potentially ordering the screws to attach it might be worthwhile, would be good information to add about the water inlet valve.
Indeed, inspecting the water inlet vale showed a slow leak. Getting the replacement part was fine, and it fit the electrical, water inlet (existing 90-degree water inlet elbow), and water outlet connections just fine - but the original machine screws that held on the original water inlet valve did not work. It took a little research to figure out the new type of screw required, which was apparently a 10/16 Type AB, which seemed to be a less common type of sheet metal screw (with a point), as opposed to the original flat-ended machine screws. So, after ordering those separately (which were a bit expensive), it went together fine.
A note on the water inlet valve part just indicating the the threading on those parts has changed over time, so potentially ordering the screws to attach it might be worthwhile, would be good information to add about the water inlet valve.
Parts Used:
-
Edward from E LONGMEADOW, MA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Socket set, Wrench (Adjustable)
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old fan had broken blade, needed to be replaced
Unplugged the refrigerator then used the cordless drill to remove the 6 screws on the access panel on the back of the fridge to be able to get to the fan. Was able to pull the fan off by hand and push the new fan on by hand. Plugged the refrigerator by in and watched the fan run for a few minutes then replaced the access panel. Really quick and easy repair.
Parts Used:
-
Ron from BAKERSFIELD, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost Heater too old
I disconnected the old defrost heater removing 2 small screws and the electrical connectors, afterward I attached the new part, reconnecting back the electrical connectors and screwing the removed 2 screws.
Parts Used:
-
paula from KEY BISCAYNE, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:1- 2 hours
-
Tools:Wrench set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken light switch
This was so easy I think it took me 2 minutes. I am not very mechanically inclined but that didn't matter! Works perfect thank you!
Parts Used:
-
Deborah from BRADLEYVILLE, MO
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Parts Used:
-
Roscoe G from ROCHESTER, NY
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wrong part shipped
Repair was not done using th part shipped. We went with the guide of the parts on the refrigerator. It would have helped if we could communicate (email or verbally)( with your parts center to verify the part we were ordering or on how to install it. We could wait for few days for a response. I am still waiating for instructions to return the part. It was a futile effort on both sides.
Your response would have helped tremendously..The picture was not adequate. Your group should be accessible to your customers.
Your response would have helped tremendously..The picture was not adequate. Your group should be accessible to your customers.
Parts Used:
-
Marie from ROCHESTER, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy Fan Motor
Simple. Rolled the refrigerator out , unplugged the 120 volts AC outlet.(1) Unplugged the wiring from the cabinet to the fan (white (three pin connector)). (2) Removed the two 5/16 inch screws holding the rear motor bracket . (3) Removed the fan blade from the motor shaft by applying slight pressure, pulling if off the old motor shaft. (4) removed the rubber isolator from the frame and from the rear of the old motor. (5) placed the rubber isolators back on the motor and frame. (6) Pushed the new motor back into the frame and re-installed the fan assembly. (7) remounted the fan with the rear support and the two 5/16 inch screws. Reconnected the three wire connector. Just checked the fan blade assembly to make sure they were not hitting the fan shroud. Fan blades should sit just partially inside the shroud to make sure it produces maximum airflow.
(8) Reconnected the 120 volt AC and waited for the compressor to cycle back on... Nice quite fan... Thanks
(8) Reconnected the 120 volt AC and waited for the compressor to cycle back on... Nice quite fan... Thanks
Parts Used:
-
THOMAS from MEBANE, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
had no access cover on back
-
Ronnie from BATON ROUGE, LA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bulb out
I ordered the part, within two days we had received it. My husband put the part in and I really don't know what he used doing so. All I know is that the light works now and we don't have to use the flashlight. Thanks a lot.
Parts Used:
-
Kenneth from Rowe, VA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light would stay on when door closed
Extremely easy repair, the hardest part was getting the old switch out. I used a pair of needle nose pliers to squeeze the tabs in and it came right out.
Parts Used:
-
James from Glendale Heights, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers
3 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broke fan blade cleaning unit
Ordered part came in 3 days. Removed plug and rear cover. Pulled off old fan . Installed new fan by pushing it on to shaft. Plugged unit back in to check operation, installed rear cover. Done. Part fit perfect. Thanks to this site you folks are great !
Parts Used:
-
Mark from DEPEW, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights did not work, bulbs were good
Took out the light sockets, plugged in the new ones. I found the manual on line to find the part numbers. Parts select parts were perfect
Parts Used:
-
Donita from O FALLON, MO
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
40 year old refrigerator brittle light switch fell apart
with a jewelry screwdriver I pried the lock tab in and pulled switch down carefully, the hardest part was that the power wire connector was stuck on good but the pliers and the jewelry screwdriver was its match for a bout 5 minute for one connection a simple pull off prong connection. After the wire connected back to switch it popped back in SNAPP
Parts Used:
-
Loren from EL PASO, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!