Freezer not defrosting
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Parts Used:
DEFROST TIMER
  • Tom from Argyle, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not run. Everything in the freezer was spoiled.We were on vacation when it happened so we didn't know we had a problem until we got home. Big mess.
I knew from a problem years ago that the Thermostat was the likely cause so I ordered a new part and replaced it. Only need a phillips head screwdriver to remove the part and add the new one..
Parts Used:
Temperature Control Thermostat
  • Sonya from PUNTA GORDA, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squealing noise and bottom half of freezer only froze
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option would have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
Parts Used:
FAN MOTOR EVAP 115V
  • Walter from SALT LAKE CTY, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was running too warm
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Parts Used:
DEFROST TIMER
  • Jeanne from SAN ANTONIO, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I Lost The Key
I order another one thanks
Parts Used:
Freezer Door Key
  • VICKIE from DAWSON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor keep running would not cool.frozen coil
As per instructions.removed inside shelves.removed back cover over coil let thaw.removed old thermostat &clips as per instructions.replaced with new.
Parts Used:
Defrost Heater
  • Mark from SEYMOUR, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
wouldn't freeze, bottom of freezer still cold, but middle and higher areas were warm and everything was thawing out.
very simple,started by turning off the power to that outlet (in breaker panel) then removed the 3 bottom screws, 2 side screws and 3 top screws (all 8 screws are Phillips head) in order to remove the panel. Disconnected the motor (unplugged it) and removed the 2 screws holding the motor in place to remove the motor. I installed the Fan on the new motor, and remounted it in place , reconnected it and replaced the panel and all 8 screws. (and the side seals push back into place easily after you replace all the panel screws.
Very easy, it took less than 15 minutes to make repairs and freezer was back in operation and back to below freezing temps in less than an hour.
Parts Used:
FAN FAN MOTOR EVAP 115V
  • George from ROAN MOUNTAIN, TN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would only run sometimes by turning the thermostat to highest position fully clockwise. Sometimes turning it full CW wouldn't turn on. Once the freezer would run on highest setting, it seemed that it wouldn't shut off. I put a thermometer inside and would read -15deg when running. +15-20deg.
Replaced thermostat and it fixed the problem. Freezer comes on and turns off automatically and regulates internal temperature around 2-5 degrees.
The hardest part was extending the coiled probe tubing and forming it to fit into clamp without kinking it.
Parts Used:
Temperature Control Thermostat
  • Rex from BEDFORD, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not freezing at the top
Turned freezer off and removed cover in freezer at the bottom, notice fan blades were broken off, removed the 2 screws that were holding the fan motor in place removed fan blade and replaced with new fan blade, problem solved
Parts Used:
FAN
  • kenneth from CUT OFF, LA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Missing key
After removing the key from its shipping package I pushed it into the freezer locking slot and turned it to lock and unlock the lid and then removed it. I had no problems with this fix. Of course, I am an older gentleman with a lot of experience in repairs around my house,as well as other houses. I am sure that a less experienced person may have more of problem with this type of "repair".
Parts Used:
Freezer Door Key
  • John from DUNBAR, WV
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It wouldn't restart when it turned off
I changed the cooling control
Parts Used:
Temperature Control Thermostat
  • Mervin from BOYD, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Parts Used:
DEFROST TIMER
  • Thomas from GRANBURY, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer stopped cooling
Used Phillips head screw driver to remove panel to expose old thermostat control. Took picture with phone to use and a guide. Replaced old with new and placed panel back o . Working perfectly! 30 minute max to complete.
Parts Used:
Temperature Control Thermostat
  • Scott from ROSTRAVER TWP, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Missing a shelf
Bought the shelf and put it in. Very easy installation, just put right side in first.
Parts Used:
Wire Shelf
  • William from MESA, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Was not the correct part!!!
Was not the correct item again, I had ordered the item 2 times both times with your service person. Had to pay 2 times to return items that they sent wrong. It has now cost me over $110.00 to return your mistakes
Parts Used:
Wire Shelf
  • Janet from HILTON HEAD, SC
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25322442415
16 - 30 of 54