Ice maker stopped making ice
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
Parts Used:
Replacement Ice Maker
  • Daniel from DAVISBURG, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Parts Used:
Refrigerator Water Fill Cup & Bearing
  • Aliki from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Amana thermostat rusted
Add the new one it was slightly different than the original but it worked out perfect.
Parts Used:
Cold Control Thermostat Light Bulb - 40W
  • Lawrence from LAGRANGEVILLE, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Refrigerator Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Parts Used:
Replacement Ice Maker
  • Raymond from Panama City Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Tonya from Grand Prairie, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
Parts Used:
Replacement Ice Maker
  • Ross from Sun Lakes, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No leveling legs
Ordered the leveling bolts, very fast shipping, parts correct as shown. Purchased a condo by the shore, frige had no levelers, they went in smoothly & was done in no time.
Steve
Parts Used:
Refrigerator Leveler
  • stephen from montgomery, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Parts Used:
Refrigerator Door Switch
  • THOMAS from WILLARD, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Parts Used:
Refrigerator Door Switch
  • anthony from HAVELOCK, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Parts Used:
Refrigerator Door Switch
  • David from Hemet, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Parts Used:
Refrigerator Run Capacitor
  • Barbara H. from South Hill, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Parts Used:
Replacement Ice Maker
  • richard from colorado springs, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!