The ice tray would no longer release ice
Just took old ice tray out and put new one right in place in less than 30 seconds. I am very pleased with how fast the tray arrived after being ordered. if only everything ordered could be made this simple. You are a great company to deal with.
Parts Used:
Tray
  • Dennis from Rocky Mount, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
evaporator coils were frozen solid and air wasn't flowing across them

read all directions first, then consider which steps you'd like to take

in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked


- if no blockages and air is flowing between the sides...

- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)

- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it

-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
Parts Used:
Defrost Heater - 500W 115V
  • Cami from Carmel, IN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Valve was dead
This was very easy and pretty fast to do and its working great...all for $40 bucks ! you can do this...trust me!
Parts Used:
Single Outlet Water Valve Kit
  • Joseph from Bloomfield Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice would not come out of try completely due to age and residue buildup
After trying to clean and use chemicles to remove residue, I found that it would not work. Ice would build up in tray causing an overflow in the fill process. this would freeze cubes in tray below causing dispenser not to work properly, New tray seemed to solve the problem. Removed old and installed new
Parts Used:
Tray
  • Donald from Easthampton, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Parts Used:
Condenser Fan Motor Kit
  • Douglas from Mesa, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost light on,not getting cold enough
remove all tray,remove back panel,cut out out old heater adn replace with new heatger,refitted back panel and alll tray.
Parts Used:
Defrost Heater - 500W 115V
  • Amrat from Pomona, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
Parts Used:
Condenser Fan Motor Kit
  • Paul from Lowell, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Socket set
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan making noise
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Parts Used:
Condenser Fan Motor Kit
  • Richard from North Easton, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Wrench set
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Location of the run capacitor was not as the video described.
It was easy after it was apparent that the run capacitor was plugged into the compressor. This was determined from a parts diagram of the actual model refrigerator. The part was the same but the location on the video was wrong. A large screwdriver was used to unplug the capacitor from the compressor. The temperature range of the refrigerator is still too wide but it's colder.
Parts Used:
Run Capacitor
  • Robert from Webbers Falls, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My amana side to side freezer stoped freezing i found parts select and helped my get a part that by % would be the problemand it worked thanks
I replaced the run capacitor wich is located near the compressor, i first turned power off to fridge than remuved capacitor checked for continuity and the capacitor was the problem thanks
Parts Used:
Run Capacitor
  • Martin from SAN ANTONIO, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker was not working.
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice maker. Gregg in PA.
Parts Used:
Single Outlet Water Valve Kit
  • GREGG from WEST CHESTER, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
We would come home from wintering in Texas and the ice maker would again work for about a week. Decided to replace the valve because it wasn't expensive.
Replaced the valve and cleaned all the coils at the same time. The ice maker is spewing out ice. Wife is happy again.
Parts Used:
Single Outlet Water Valve Kit
  • Tom from MINNEAPOLIS, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Parts Used:
Condenser Fan Motor Kit
  • Kevin from COVINGTON, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker was asking for water, but no ice
replaced the wiring harness, it contains a heating element that allows the water to pass through the discharge tube and not freeze up. I installed the ice maker originally so this was fairly easy repair once I knew the wiring set up.
Parts Used:
HARNS-WIRE
  • Lowell from Tonica, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator and freezer not cooling as required, compressor running continually
Turned refrigerator and freezer controls to off, removed icemaker bin, unplugged icemaker plug and removed two screws holding icemaker in place and removed icemaker. removed screws holding auger motor and freezer compartment light plate, unplugged and set aside. Remover screws holding freezer coil cover in place and removed cover. Allowed coils to defrost completely and then removed screws that hold the two defrost heater coil mounting plates in place, unplugged the two wires that connect the defrost heater coils to the connector block that is located above the freezer coil. Remove the entire defrost heater by working the connecting wires out from along side the freezer coil. Remove the clips that hold the old defrost heater elements to the mounting plates. Install new heating elements into the two mounting plates with the clips. Reinstall the two mounting plates to brackets on freezer coil and reinstall connecting wiring up to connector block and reconnect them. Reinstall freezer coil cover, icemaker auger motor and freezer compartment light plate, and icemaker and bin to complete job. Due to the confined space in the freezer compartment, reinstalling the freezer coil cover and light plate was difficult as I could only use one arm at a time resulting in many dropped screws.
Parts Used:
Defrost Heater - 500W 115V
  • Jack D from CLEBURNE, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
1 person found this instruction helpful.