Refrigerator and freezer not cooling as required, compressor running continually
Turned refrigerator and freezer controls to off, removed icemaker bin, unplugged icemaker plug and removed two screws holding icemaker in place and removed icemaker. removed screws holding auger motor and freezer compartment light plate, unplugged and set aside. Remover screws holding freezer coil cover in place and removed cover. Allowed coils to defrost completely and then removed screws that hold the two defrost heater coil mounting plates in place, unplugged the two wires that connect the defrost heater coils to the connector block that is located above the freezer coil. Remove the entire defrost heater by working the connecting wires out from along side the freezer coil. Remove the clips that hold the old defrost heater elements to the mounting plates. Install new heating elements into the two mounting plates with the clips. Reinstall the two mounting plates to brackets on freezer coil and reinstall connecting wiring up to connector block and reconnect them. Reinstall freezer coil cover, icemaker auger motor and freezer compartment light plate, and icemaker and bin to complete job. Due to the confined space in the freezer compartment, reinstalling the freezer coil cover and light plate was difficult as I could only use one arm at a time resulting in many dropped screws.
Parts Used:
-
Jack D from CLEBURNE, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
Parts Used:
-
Paul from Lowell, MI
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Socket set
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Location of the run capacitor was not as the video described.
It was easy after it was apparent that the run capacitor was plugged into the compressor. This was determined from a parts diagram of the actual model refrigerator. The part was the same but the location on the video was wrong. A large screwdriver was used to unplug the capacitor from the compressor. The temperature range of the refrigerator is still too wide but it's colder.
Parts Used:
-
Robert from Webbers Falls, OK
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My amana side to side freezer stoped freezing i found parts select and helped my get a part that by % would be the problemand it worked thanks
I replaced the run capacitor wich is located near the compressor, i first turned power off to fridge than remuved capacitor checked for continuity and the capacitor was the problem thanks
Parts Used:
-
Martin from SAN ANTONIO, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker was not working.
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice maker. Gregg in PA.
Parts Used:
-
GREGG from WEST CHESTER, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
unit would not freeze
I removed all covers then removed screws from element and disconnected wires and removed it.
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
Parts Used:
-
Johnnie from Saginaw, MI
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Failure
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!
Parts Used:
-
Al from Tonka Bay, MN
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Socket set
2 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer and food section too warm
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Parts Used:
-
William from Milford, MA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Socket set
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
Parts Used:
-
George from Belhaven, NC
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan motor had gone bad
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
Parts Used:
-
william from whitwell, TN
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set, Wrench set
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Solenoid stem had seperated from valve seat.
Turn off water, removed two mounting screws, unplugged solenoid, removed incoming water connection and plastic pipe to ice maker. Installed new valve, connected water lines, reconnected plug, remounted with screws. Turned water back on, over rode power to ice maker and checked for leaks. Total time about 5 minutes. Very easy repair.
Parts Used:
-
Gary from Lewisburg, WV
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Wrench (Adjustable)
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Parts Used:
-
Curtis from Sedona, AZ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the ice was sticking to the tray and would fill each time it cycled the flood the dispencer
-
Edward from Claymont, DE
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Parts Used:
-
Kevin from COVINGTON, LA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker was making hollow ice, then no ice
Very simple repair. Ice maker was operating, but not receiving water. Once new valve was in place it works like new.
Parts Used:
-
Arthur from Easthampton, MA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Wrench (Adjustable)
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!