Water leaking from under refrigerator.
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for leak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.

The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
Parts Used:
Evaporator Drip Tray
  • Ronald from DELRAN, NJ
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise coming from defrost timer
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Parts Used:
Defrost Timer
  • Thomas from Pottstown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cover Pan Crisper(bottom glass shelf and frame) were broken
New part slipped right into the studs and fit perfectly
Parts Used:
Crisper Cover with Glass
  • anthony from ormond beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My refrigerator ran constantly and never got cold!
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever and I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Parts Used:
Defrost Timer Refrigerator Door Switch
  • Brandon from Fort Wayne, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
installed ice maker
From the time I started to finish I worked 3 hours, this included installing the new ice maker, cutting into the cold water line in the basement and installing a t with a 6inch piece of pipe with a compression valve to connect to the small cooper tube, this is worth your time to do it this way, its a lot better connection than the small pierce valves that come with the kit, they will leak over time. I installed the filter in the waterline in the basement for easy access
Parts Used:
ICEMAKER
  • Dennis from Spring Valley, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench set
13 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not cycle
removed the defrost timer and replaced with new unit now i have a refrigerator again
Parts Used:
Defrost Timer
  • Maxine from Birmingham, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator door was making a popping noise when opening and closing
Not being a handyman I found this job realtively easy.I took most of stuff off fridge door, to make door easier to handle. I then undid top hinge door screws, 3 of them, lifted door out., replaced 2 cams.When putting door back on fridge, you have to make sure door is in exact position and top hinge is lined up exactly, or door will continue to pop a little.It took me a couple of times to get top hinge lined up exactly.
Parts Used:
Door Closing Cam Kit
  • Vincent D from Blackwood, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor would not kick on automatically
I removed the two screws that were readily in view. I then figured out the there was a faceplate which I was able to pry off after removing the temp control knobs. The temp control unit was easily accessible and was held by two screws which I removed with the nut driver. The only difficult part was replacing the plastic tubing which covered the sending unit.
Parts Used:
Thermostat Assembly
  • Robert from Brooklyn Center, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer/refrigerator no air flow
Using a 1/4" nut driver and a philips screwdriver I removed all the screws in the shelf brackets and coil cover and removed coil cover. Removed fan blade and then faulty motor (held in with clips) Installed new motor-two wires (power) and ground (green) pushed fan blade back on and tested, then reinstalled all panels and shelf brackets.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Jim from Au Sable Forks, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Parts Used:
Light Socket Kit
  • martin l. from JACKSONVILLE,, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
part of a freezer support bracket was missing
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Parts Used:
STUD-SHELF
  • peter from saint augustine, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!