The refrigerator leaked water every time the ice maker filled.
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
Parts Used:
Ice Maker Water Fill Tube Kit
  • Robert E. from Darien, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Parts Used:
Condenser Fan Motor Kit
  • George from Glenwood, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Our ice maker did not work.
I turned off the water supply and disconnected the power. Then I removed the back cover plate and the two water lines. Fortunately the water lines are a different size so it is not confusing which line goes on each outlet. Then I loosened the two screws that fasten the valve assembly. It requires a nut driver with a flexible drive or a 1/4" socket set with a "U" joint. We were then able to disconnect the third water line on the back side of the valve assembly. I then reversed the sequence to install the new valve. The only difficulty is getting the screws started on the valve assembly.
The trouble shooting guide in the Kitchen-aid user manual is totally inadequate. I bought and replaced the whole icemaker unit when all I needed was the valve.
Parts Used:
Dual Outlet Valve Kit
  • Jay from Flower Mound, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Parts Used:
Water Tube Kit
  • Melvin from OPELIKA, AL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fan quit
I took the old one out and put the new one in. EASY!
Parts Used:
Evaporator Fan Motor Kit
  • donn from Ranier, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker leaking or overflowing into ice bend
first bought new ice maker installed it-didn`t fix the problem. next bought fill tube kit and dual outlet vale -installed those ice maker works GREAT no leaks -no ice froze together in bend. thanks for the help GUYS.
Parts Used:
Dual Outlet Valve Kit Ice Maker Water Fill Tube Kit
  • LARRY from DYER, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench set
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker not working
Started the replacement of the existing dual outlet valve by removing cardboard covering the lower back of the refrigerator exposing the outlet valve. Closed the water supply valve at the wall. Removed the hose bibb water supply connection on the outlet valve by hand as it is only hand-tight. I used a small plastic container to catch the minimal amount of water left in the copper line. I removed the electrical connection on each solenoid valve (one for the in-door water supply and one for the icemaker supply). I removed the plastic supply lines from the outlet valve. I removed the screws on the bracket attaching the dual outlet valve to the refrigerator vertical rail. I reconnected the electrical connectors to the valve. I reattached the plastic supply lines to the valve, but did not tighten them fully at this point. I secured the bracket on the new valve to the existing screwholes on the refrigerator rail. The new outlet valve does not have a hose bibb connector, it has a compression fitting for the supply. I reused the existing copper supply line from the wall angle-stop valve to reconnect to the new outlet valve. (It would have been best to have cut the copper line and used a new furrel on the copper line). Note that the supply line now comes into the outlet valve from the top, not the rear as on the old valve, so now the dual outlet valve sticks out beyond the frame of the refrigerator. I tightened the nuts on the plastic supply lines on the valve. I had to cut the cardboard cover around the new outlet valve. Resecured the cardboard cover to the back of the frig. Checked for leaks, turned the icemaker on by lowering the shutoff arm, and after a few moments, the outlet valve opened, water flowed into the icemaker, and all is well.
Parts Used:
Dual Outlet Valve Kit
  • Hal from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator would freeze up and stop cooling, I would turn off defrost over a 24 hour period by leaving the freezer door open. Then turn it back on and it would cool like crazy for about a week and then it would freeze up agian. This went on for about a month then I knwe the problem was in the defro
The first thing to do was determine what part of the defrost circuit was bad. (it could have been the defrost timer assembly or the defrost heater or a bad wire in the circuit). To do this I took the cover off of the refrigerator temp control to see the timer. Taking a large screw driver I rotated the timer (clockwise) until I heard the compressor cut off. Then I placed a mark on the timer to note its location and waited to see if the mark moved( this indicated the motor was running). After 20 minutes the compressor kicked back on and the timer had rotated, this told me the timer was at least rotating. The next step was to see if there was voltage going to the defrost heater around the freezer evaporation coil. (The heater is what melts the frost of the evaporation (cooling) coils
This requires the removal of all the shelves, ice maker, and all the covers in the freezer section to expose the evaporation coil.
The defrost heater wraps around the outside edges of the evaporation coil. The heater is suppose to come on for 20 minutes every 8 hours to keep the evaporation coil from becoming covered with frost which will prevent the air from circulating into the refrigerator section.
I found where the heater leads plug into the back wall of the freezer and with the power on and in the defrost cycle (turn or index the timer around with the large screw driver until the compressor cuts off again). Carefully read across these two heater leads and check for 120 VAC. Noting there was 120vac across these two leads I then turned the refrigerator off and unplugged the refrigerator from the wall.
Now with the Volt Meter set to the Ohms setting I unplugged the two heater leads with the needle nose pliers and read the ohm value across the two wire leads of the heater element. (I got lucky and found a schematic folded up and stuck just behind the front grill at the bottom of the freezer). The schematic told me the ohm value should have been 22 ohms. However, my value was 0 ohms this told me the heater had an open circuit (it had a broken wire inside the heater element). I located the correct part using the model # on the Part Select website and ordered the defrost heater element for my model refrigerator. I received the part in three days.
Now for the fun part, of removing and installing the new element.
This is not brain surgery but … it is not for the faint at heart either, you must be able to work in tight areas and be agile enough to sit on the floor while reaching the back of the freezer and be patient and deliberate with your moves. (kind of like playing the Milton Bradley game “Operation” as a kid)
Next step is to remove the two top screws holding the evaporation coil to the back of the freezer, then remove the cover to expose the refrigerant lines inside the freezer, remove the two foam side supports holding the coil centered in the back of the freezer and then VERY carefully lift the evaporation coil straight up to un- hook it from the bottom clips which hold the bottom of the coil stationary. Then gently remove the two aluminum side plates from the coil by bending the tabs that hook these plates to the curved refrigerant coils they are hooked around. With the side plates removed then carefully un- hook the 4 clips which hold the heater in place around the evaporation coil. Using a pair of needle nose pliers unplug the heater leads from the back wall contact point (Remember to be sure and unplug refrigerator before doing this) At this point VERY carefully lift up slightly and gently pull the bottom of the coil out (trying to keep the top of the coil at the same elevation and parallel to the back wall pull the bottom out to a point where the heater element can be slid down and out of the evaporation coil as it is basically woven thru the coil assembly to efficiently defrost the coil.
Once the heater is carefully slipped down and out of the evaporation coil, replace the heater element with the new one by feeding the wires bac
Parts Used:
Heater
  • Charles from Dripping Springs, TX
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Chirping sound coming from the freezer-old gasket on food door causing air leakage r
Removed shelving,ice maker & other air deverters to get at fan motor. Disconnected power, then removed motor by removing screws holding motor assembly in place. Push fan blade on to motor reconnect wiring.
Chirping stopped and ice cream is now rock hard.

Food door gasket was more time consuming than hard. Loosen old gasket screws with not driver. Gasket is then easily removed. Reinstall gasket, but keep retaining strips loose so you can adjust gasket for a correct fit.
Parts Used:
Evaporator Fan Motor Kit Fresh Food Door Gasket
  • JAMES from WAUPACA, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Parts Used:
Refrigerator Door Switch
  • Michael from East Meadow, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Parts Used:
Condenser Fan Motor Kit
  • Peter from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Parts Used:
Condenser Fan Motor Kit
  • David from Choctaw, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Parts Used:
Refrigerator Door Switch
  • Antonio from San Antonio, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not work.
I replaced the dual outlet valve and deiced the filler tube going to the ice maker. I removed the filler tube and ran hot water on it. I believe the old filler valve was leaking letting water slowly into the filler tube where it eventually froze solid.
Parts Used:
Dual Outlet Valve Kit
  • Ed from Glendora, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
6 of 7 people found this instruction helpful.