MT4070SKQ0 Whirlpool Microwave - Overview
Sections of the MT4070SKQ0
[Viewing 6 of 6]Manuals & Care Guides for MT4070SKQ0
Click to downloadKeep searches simple, eg. "belt" or "pump".
Door Interlock Switch Kit
PartSelect #: PS373050
Manufacturer #: 4392027
This kit contains 2 switches - 15 Amp - 125/250 Volt with 3/16" terminals.
$132.18
In Stock
Order within the next 9 hrs and your part ships today!
Fastener Screw
PartSelect #: PS389896
Manufacturer #: 8169475
Sold individually.
$9.84
Special Order
Microwave Spring
PartSelect #: PS11742286
Manufacturer #: WP4158178
Door open button spring.
No Longer Available
SCREW
PartSelect #: PS12728594
Manufacturer #: W11380570
Sold individually. For white and almond models.
$26.58
Special Order
Microwave Turntable Motor
PartSelect #: PS11749221
Manufacturer #: WPW10159107
This motor rotates the glass turntable in the microwave.
$150.46
In Stock
Order within the next 9 hrs and your part ships today!
Microwave High Voltage Diode Wire
PartSelect #: PS11745270
Manufacturer #: WP8205489
This part allows power to go only one way.
$61.20
In Stock
Order within the next 9 hrs and your part ships today!
Microwave Screw
PartSelect #: PS11742285
Manufacturer #: WP4158079
This screw is for microwaves.
A qualified technician should install this part if it requires accessing internal components of the microwave or microwave door. High-voltage capacitors can retain a l...
$7.95
Special Order
Wave Guide Cover
PartSelect #: PS392144
Manufacturer #: 8184278
This part guides the waves to the inside of the microwave to cook your food.
No Longer Available
Questions And Answers for MT4070SKQ0
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Symptoms of the MT4070SKQ0
[Viewing 5 of 5]No heat
Fixed by
these parts
these parts
Show All
Won’t turn on
Fixed by
these parts
these parts
Show All
Door stuck closed
Fixed by
these parts
these parts
Show All
Tray won’t turn
Fixed by
these parts
these parts
Show All
Doesn’t shut off
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Microwave worked intermittently depending on how door was closed
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and also took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
Parts Used:
-
Robert from Bainbridge Island, WA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
67 of 85 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave went dead while in use.
1. removed vent across the top to gain excess to Screw holding control in place. 2. Removed control panel to access Fuse. 3. Remover fuse after pulling plug. 4.Tested fuse for continuity with volt ohm meter noting no continuity.5. Orderd new fuse. 6. receeived new fuse and installed infuse holder.7. plugged microwave plug back in receptical and tested unit now working OK.Reversed steps 2 & 1 job complete
Parts Used:
-
Keith from Georgetown, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
35 of 42 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Close the door on the microwave, punch in the # nothing happened
I removed the unit from the wall. Took the cover off. Set the unit on its side. It revealed the working parts. Removed the old micro switches. Put in the new oness. Presto, it worked. Very easy for me.
The parts was delivered almost before my notice they were shipped.
The parts was delivered almost before my notice they were shipped.
Parts Used:
-
Robert S. from Stafford, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
15 of 23 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!