This temperature sensor, also referred to as a thermistor, is a genuine replacement component compatible with various appliance models. It works in coordination with the control board to monitor inter...
This clear inner glass lets you see inside your LG oven while keeping the heat in. If your oven glass is cracked or chipped, replacing it helps restore energy efficiency and safe cooking. It’s made to...
Your LG range is crucial to your daily cooking, and it deserves nothing but the best replacement parts. Enter the OEM Radiant Surface Element. Directly crafted by LG, this finest quality part boosts y...
Upgrade your oven with this durable gliding shelf rack, designed to provide a stable surface for baking, roasting, and broiling. Its smooth sliding design makes it easy to insert and remove dishes, of...
Ask our experts a question about this model and we'll get back to you as soon as possible!
1 question answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Victor
March 11, 2025
Right front burner wont shut off
For model number LSC5622WS
Hi Victor,
Thank you for your question. If the right front burner will not shut off, you will need to check both the element and the burner switch that controls it with a multimeter on the Rx1 setting to see which part is causing the issue. Before removing and checking these parts, unplug the range from the electrical outlet. When testing the element, touch each of the terminals one at a time with one probe while holding the other probe to the outside surface of the element. If either terminal shows continuity, it is defective. To test the entire element for continuity, place each of the probes on the terminals, one on each. You should receive a reading of 19 to 115 ohms. If you get any other reading, you will need to replace the element. When testing the burner switch, touch the L1 and H1 terminals with the probes. Once you have completed that test, touch the probes to the L2 & H2 terminals. If your test results indicate that there is no continuity between one or both sets of terminals, you need a replacement infinite switch. We hope this helps
Was this helpful?
Thank you for voting!
< Prev
1
Next >
✖
Ask a Question
Ask our experts a question on this model and we'll respond as soon as we can.
Removed the back of the Range. Removed one wire at a time from the old PCB and placed it in position on the New PCB. Then secured the New PCB in the holder.