Error Code 02 on LG thru wall AC/Heat Pump
I followed an on line schematic of my unit to find the correct part number and location of the part in the unit.
Parts Used:
THERMISTOR ASSEMBLY,NTC
  • Danny from Trussville, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Capacitor went out
Unplugged and replugged everything and it worked very easy job thank you
Parts Used:
Capacitor
  • Al from CROSS PLAINS, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?