JVM1790WK01 General Electric Microwave - Overview

Sections of the JVM1790WK01

[Viewing 8 of 8]

Manuals & Care Guides for JVM1790WK01

Click to download
Keep searches simple, eg. "belt" or "pump".
Halogen Light Bulb - 120V 20W – Part Number: WB25X10019
Halogen Light Bulb - 120V 20W
★★★★★
★★★★★
(4)
PartSelect #: PS2351821
Manufacturer #: WB25X10019
This halogen light bulb is a replacement part for the bulb behind the top grill in your microwave. It is sold individually.
$33.98
  Special Order
Microwave Fuse – Part Number: WB27X10928
Microwave Fuse
★★★★★
★★★★★
(1)
PartSelect #: PS1481237
Manufacturer #: WB27X10928
This ceramic microwave fuse is just over an inch in length. It is white in the center, and metal on both ends. This is a 20-amp fuse, and is used to power your microwave. If the touch pad on the micro...
$25.31
  Special Order
Primary Door Interlock Switch – Part Number: WB24X10047
Primary Door Interlock Switch
★★★★★
★★★★★
(3)
PartSelect #: PS237015
Manufacturer #: WB24X10047
This interlock switch is located in the door latch.
$54.49
  Special Order
Grease Filter – Part Number: WB06X10654
Grease Filter
PartSelect #: PS1018833
Manufacturer #: WB06X10654
The grease filter can be found on the bottom of the microwave. If your grease filter is damaged, it will not effectively capture grease that builds up when your microwave is in use. To replace the gre...
  No Longer Available
Glass Turntable Tray – Part Number: WB49X10176
Glass Turntable Tray
★★★★★
★★★★★
(5)
PartSelect #: PS1016243
Manufacturer #: WB49X10176
This tray rotates in your microwave ensuring more even temperatures.
$103.37
  Special Order
Microwave Holder – Part Number: WB02X10750
Microwave Holder
★★★★★
★★★★★
(1)
PartSelect #: PS224021
Manufacturer #: WB02X10750
Sold Individually.
$21.50
  Special Order
Monitor Interlock Switch – Part Number: WB24X25397
Monitor Interlock Switch
PartSelect #: PS11766871
Manufacturer #: WB24X25397
If your microwave won’t start even though the door is shut, this switch might be the reason. It helps your microwave know the door is closed so it can run safely. This genuine part is easy to install ...
  No Longer Available
Rotating Ring – Part Number: WB06X10705
Rotating Ring
PartSelect #: PS1480805
Manufacturer #: WB06X10705
The rotating ring in your microwave rests under the microwave plate, and allows it to rotate when the microwave is running. It is a round plastic ring with 3 wheels spaced out around the perimeter. If...
  No Longer Available
Vent Grille - White – Part Number: WB07X10931
Vent Grille - White
PartSelect #: PS1020747
Manufacturer #: WB07X10931
Need to maintain the performance of your microwave? You're in the right place! Our GE Vent Grille is designed to keep your microwave operating at its best by protecting the internal components, while ...
  No Longer Available
Cover Assembly – Part Number: WB02X32719
Cover Assembly
PartSelect #: PS12709819
Manufacturer #: WB02X32719
Dealing with a microwave that's not performing as it should? Consider the 2 Stirrer Fan Cover Assembly ? it could be just the solution you need. This vital component is crafted to keep dirt and grease...
  No Longer Available
Wave Guide Cover – Part Number: WB06X10655
Wave Guide Cover
PartSelect #: PS1020649
Manufacturer #: WB06X10655
This part is used to protect the parts that are located behind the canopy mica.
  No Longer Available
Door Latch – Part Number: WB02X11096
Door Latch
PartSelect #: PS952070
Manufacturer #: WB02X11096
Used to keep the microwave door closed during operation.
  No Longer Available

Questions And Answers for JVM1790WK01

Ask our experts a question about this model and we'll get back to you as soon as possible!

7 questions answered by our experts.
  • 1
  • 2
Sort by:
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
David
December 10, 2019
How can i order a vent fan cover
For model number JVM1790WK01
PartSelect logo
Hello David, thank you for your question. The replacement grille for this unit is Part #: PS1020747. Please enter the part number into the site for current price and availability. Good luck with your repair!

3 people found this helpful.

Was this helpful?
Thank you for voting!
Jim
January 28, 2020
This model has two lights one under the unit (night light) and one inside the unit. I cannot find instructions for replacing the inside light.
For model number JVM1790WK01
PartSelect logo
Hello Jim, Thank you for the question. Here is a link to a How to Video that may help. Good luck with the repair. https://www.youtube.com/watch?v=-yUtoBg17Jg

2 people found this helpful.

Was this helpful?
Thank you for voting!
Related Parts:
Ronnie
March 26, 2024
the exterior plastic ventilation cover is broken, I tried to glue together no luck - Is there a replacement part I can buy ?
For model number JVM1790WK01
PartSelect logo
Hi Ronnie, thank you for your question! The vent grille for your model is part number PS1020747. Please reach out to customer service if you need help placing an order!

2 people found this helpful.

Was this helpful?
Thank you for voting!
Related Parts:
Ed
June 1, 2025
Underside light out part.# needed
For model number JVM1790WK01
PartSelect logo
Hello Ed, thank you for reaching out. The light bulb you are looking for is part number PS2351821. We hope this helps!

Was this helpful?
Thank you for voting!
Related Parts:
Raymond
August 11, 2022
Everything seems to be working except it does not heat up, can this be repaired? Thank you.
For model number JVM1790WK01
PartSelect logo
Hello Raymond, Thank you for the question. For safety reasons, since the microwave capacitor can still store electricity even when the microwave is unplugged, it is usually advised that you discharge the capacitor before any attempt at repair. We have included a link on how to do so. There are two parts we suggest testing. First we suggest checking the Diode, It should read around 50K Ohms. You can also check the Magnetron. The magnetron can be tested with an multi meter set on the highest scale. Across the terminals, you should read 0 ohms (or .5 ohms). Test both terminals to ground with one lead and make sure it is not shorted. If you need help placing an order, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you!

Was this helpful?
Thank you for voting!
Related Parts:
Additional Links:
  • 1
  • 2

Common Symptoms of the JVM1790WK01

[Viewing 6 of 6]
Won’t turn on
Fixed by
these parts
Fixing Fixing Fixing
Show All
No heat
Fixed by
these parts
Fixing Fixing Fixing
Show All
Touchpad does not respond
Fixed by
these parts
Fixing
Show All
Door not closing properly
Fixed by
these parts
Fixing Fixing
Show All
Doesn’t shut off
Fixed by
these parts
Fixing Fixing
Show All
Tray won’t turn
Fixed by
these parts
Fixing Fixing Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Microwave completely stopped working
Turned out the issue was easily solved by replacing a single, inexpensive fuse.

First off, UNPLUG THE MICROWAVE.

The fuse is located under the plastic grill at the top of the microwave. It's held on by two screws. Once you've removed the screws and taken off the plastic grill, you go to the right side of the microwave and remove another screw that holds a small metal grill in place. Removing the small metal grill is probably the toughest part of this repair. You kind of have to rock it back and forth a bit to get it to release. Once that's off, you can get to the fuse. I removed the burnt out one with a pair of needle nose pliers. I also put a small piece of cardboard under the fuse when I did this so I didn't accidentally drop it into the innards of the microwave. I did the same thing when I replaced the new fuse. I then plugged the appliance back in and made sure it worked. Once that was confirmed, I replaced both grills.
Parts Used:
Microwave Fuse
  • Kim from Cliffside Park, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
964 of 1257 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Under the vent light bulbs needed to be replaced
Turned of f the circuit breaker to the microwave. Unscrewed the cover (1 screw!) popped out the old bulbs and plugged in the new ones, using the bubblewrap as a handle to be sure my skin didn't touch the light bulbs so the oil from my hands didn't damage or shorten the life of the new bulbs. Turned the circuit back on. That's it!
Parts Used:
Halogen Light Bulb - 120V 20W
  • Robert from Naples, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
66 of 87 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I diagnosed the problem incorrectly: based on a previous repair.
The old fuse is perfectly good. The new ones arrived within a day.
Parts Used:
Microwave Fuse
  • Ralph from Brandon, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
66 of 139 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!