This is a genuine replacement 40 watt bulb for a microwave. The bulb is meant to light up the underside of the microwave or inside of your microwave when the door is open or during use. If your bulb i...
When your microwave isn't heating your food evenly, the problem could lie with the rotating ring assembly - a crucial piece in ensuring proper function. Our GE Rotating Ring Assembly might just be the...
$46.54
Special Order
Questions And Answers for JVM1630SPC01
Ask our experts a question about this model and we'll get back to you as soon as possible!
2 questions answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Laura
April 20, 2023
We require a new light socket (surface light socket)
For model number JVM1630SPC01
Hello Laura, Thank you for your inquiry. We show the light socket both at the bottom of the microwave and in the air duct is part# PS11721587. We hope this helps.
Suddenly stopped working and restarted if we reset the breaker.Did this about 3 times and the last time that did not work. Replaced breaker but now won't work at all. turns out not the breaker. Is this a fuse? It is only a 2018 model.
For model number JVM1630SPC01
Hi Alison, thank you for reaching out. Based on the description you have provided, the issue could be with the microwave fuse, part number PS10065167. You may need to replace it to fix the issue. We hope this solves your problem!
1. Unplug unit 2. Open door, remove two screws above the top trim piece, slide and remove trim. 3. Remove screw behind control board and top left corner, then release from position. 3b. Unplug all wire terminations and set control panel aside. 4. Remove two screws securing latch board, lift and rotate board out of position, remove three micro switches, xfer monitor switch actuator from lower pin in old board and insert in new. Install new door switches and reverse procedure to complete repair.
Note 1. Take care to located new latch board so holding tabs line up, pass through frame, and openings for door tangs line up with openings in frame before securing with screws.