GSC402-02 General Electric Dishwasher - Overview
Sections of the GSC402-02
[Viewing 2 of 2]Keep searches simple, eg. "belt" or "pump".
Dishwasher Water Inlet Valve
PartSelect #: PS259411
Manufacturer #: WD15X93
This water inlet valve is specially designed for those dishwashers that fit under the counter from 1974 To Present. The valve should be located behind the lower kickplate panel in either the right or ...
No Longer Available
Dishwasher Hose Clamp Kit
PartSelect #: PS270806
Manufacturer #: WH1X2036
This hose clamp kit contains two clamps. The smaller of the two is an inch in diameter while the larger of the two is two inches in diameter.
$22.95
Special Order
Portable Dishwasher Hose and Faucet Kit
PartSelect #: PS263169
Manufacturer #: WD35X194
This kit comes complete with the hose and coupler for hooking up a portable dishwasher to a faucet. It also contains the faucet adapter and washer.
No Longer Available
Lower Rack Roller with Clip
PartSelect #: PS259266
Manufacturer #: WD12X5026
Sold individually. Order quantity required.
$46.95
Special Order
Questions And Answers for GSC402-02
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Symptoms of the GSC402-02
[Viewing 4 of 4]Will not fill with water
Fixed by
these parts
these parts
Show All
Leaking
Fixed by
these parts
these parts
Show All
Not cleaning dishes properly
Fixed by
these parts
these parts
Show All
Not draining
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Insufficient fill water, dishes not getting clean (valve diaphram had ruptured)
1. Remove lower cover skirt.
2. Shut of water at undersink valve.
3. Unplug power cord or turn off circuit breaker.
4. Disconnect water supply line from fill valve.
5. Unplug the electrical connector from the valve.
6. Remove the 2 valve mounting bracket screws.
7. With loose valve in hand, rotate to gain access to allow release of outlet hose clamp for hose removal.
8. Remove brass fitting from old valve and install on new valve. Use teflon tape on the pipe threads only.
Install new valve by reversing the procedure.
2. Shut of water at undersink valve.
3. Unplug power cord or turn off circuit breaker.
4. Disconnect water supply line from fill valve.
5. Unplug the electrical connector from the valve.
6. Remove the 2 valve mounting bracket screws.
7. With loose valve in hand, rotate to gain access to allow release of outlet hose clamp for hose removal.
8. Remove brass fitting from old valve and install on new valve. Use teflon tape on the pipe threads only.
Install new valve by reversing the procedure.
Parts Used:
-
Don from Mount Vernon, IL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Wrench set
71 of 77 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Little/no water coming in & dirty dishes
1. Remove access panel under door. 2.Shut off hot water.3. Shut off electric to washer.4. Disconnect water line from water inlet valve.5. Remove small outlet water line from valve. Replace valve & reconnect. OR !!! 1.Take solenoid valve & bracket off of original inlet valve 2. Pull out white plastic diaphragm cover. 3. Remove diaphragm & clean out water holes with a pin. 4. Reassemble valve. 5. Reinstall original water inlet valve & save $27.00
Parts Used:
-
William from Polson, MT
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Socket set, Wrench (Adjustable)
17 of 19 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thanks for sending the correct part. You guys did a great job.
-
Albert from Dallas, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Socket set, Wrench set
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!