Models
>
D40B
D40B - Overview
Models starting with D40B
Click on the best match to narrow your results.
Keep searches simple, eg. "belt" or "pump".
Water Inlet Hose Washer
PartSelect #: PS11738697
Manufacturer #: WP16123
Sold Individually. Order quantity needed.
$10.14
In Stock
Single Hex Head Screw
PartSelect #: PS11742731
Manufacturer #: WP489069
Sold individually. The size of this screw is 1/4" hex head and 10-12 x 1/2".
$6.91
In Stock
Sensor
PartSelect #: PS3654111
Manufacturer #: 6877A30013V
Also known as thermistor.
$58.92
Special Order
Condensation Drip Pan
PartSelect #: PS11746885
Manufacturer #: WP951901
Used with dehumidifiers.
No Longer Available
Putty
PartSelect #: PS322282
Manufacturer #: 212643
Permagum sealer for refrigerant line insulation.
$71.23
In Stock
Common Symptoms of models starting with D40B
[Viewing 3 of 3]Unit says bucket is full when it isn’t
Fixed by
these parts
these parts
Show All
Leaking
Fixed by
these parts
these parts
Show All
Won’t stay on
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
bucket full light constantly blinking with error code 01 on the display
Unscrew and detached front and back panels, and inside framework holding the sheet metal to the body, after removing the sheet metal, unscrew the box enclosing the control board, use needle nose pliers to unhook the sensor module from the board and place the new sensor into the spots where the old sensor was connected (thermostat area, humidity Sensor, bucket switch, and control board). Close up the unit and your good to go.
Parts Used:
-
Seif from DETROIT, MI
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
turbo stopped spinning
Had to pop open the back. The back did not just unscrew and come off. It has to be pried off carefully. Took the turbo off and put the new one on.
Parts Used:
-
Cheryl from Bradner, OH
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The humidifier would run continuously regardless of the humidity setting.
I removed the old humidistat and replaced it with the new one which was an exact fit.
Parts Used:
-
Stephen from Richfield, NC
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!