Terry
June 21, 2023
What's causing the coils on my dehumidifier to freeze up? The fan runs & air is going into the front & coming out the back.The room temperature is above 65 degrees. Thank you
For model number AD25J0
Hi Terry, thank you for reaching out. If your dehumidifier coils are freezing up and the room temperature is above 65 degrees Fahrenheit, there may be an issue with the humidity control. We recommend checking the humidity control, part number PS11738359, to fix this issue. We hope this solves your problem!
The knob one turns to set the humidity level was removed. The two screws holding the top on were removed. The top was lifted and swung to the side. After noting which of the two wires went where on the humidistat the wires were removed. Small flat screwdrivers were used to pry back the plastic retainers on one side of the original failed humidistat. The new one was put in place, the two wires were reattached. The knob was replaced. The top was positioned and its two retaining screws replaced. A magnetic phillips screwdriver was handy but not necessary. Piece of cake! Someone with ten thumbs could do it!! Thanks for the prompt courteous attention to the returned erroneous part! Dealing with partselect. Com was a pleasure. . . . . . Thanks!! P. S. The dehumidifier works like new now!!