ACM0860AW Amana Microwave - Overview
Sections of the ACM0860AW
[Viewing 4 of 4]Keep searches simple, eg. "belt" or "pump".
Door Interlock Switch Kit
PartSelect #: PS373050
Manufacturer #: 4392027
This kit contains 2 switches - 15 Amp - 125/250 Volt with 3/16" terminals.
$132.18
In Stock
Fastener Screw
PartSelect #: PS389896
Manufacturer #: 8169475
Sold individually.
$9.84
Special Order
SCREW
PartSelect #: PS12728594
Manufacturer #: W11380570
Sold individually. For white and almond models.
$26.58
Special Order
Microwave Fuse 15 Amp 250v
PartSelect #: PS11757434
Manufacturer #: WPY01050009
$16.60
Special Order
Microwave Turntable Motor
PartSelect #: PS11749221
Manufacturer #: WPW10159107
This motor rotates the glass turntable in the microwave.
$150.46
In Stock
Wave Guide Cover
PartSelect #: PS392144
Manufacturer #: 8184278
This part guides the waves to the inside of the microwave to cook your food.
No Longer Available
Rectifier
PartSelect #: PS11738693
Manufacturer #: WP13091701
This part is also known as a rectifier.
$35.46
Special Order
Questions And Answers for ACM0860AW
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Symptoms of the ACM0860AW
[Viewing 5 of 5]Won’t turn on
Fixed by
these parts
these parts
Show All
Tray won’t turn
Fixed by
these parts
these parts
Show All
No heat
Fixed by
these parts
these parts
Show All
Doesn’t shut off
Fixed by
these parts
these parts
Show All
Door stuck closed
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Microwave worked intermittently depending on how door was closed
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and also took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
Parts Used:
-
Robert from Bainbridge Island, WA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
67 of 84 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Close the door on the microwave, punch in the # nothing happened
I removed the unit from the wall. Took the cover off. Set the unit on its side. It revealed the working parts. Removed the old micro switches. Put in the new oness. Presto, it worked. Very easy for me.
The parts was delivered almost before my notice they were shipped.
The parts was delivered almost before my notice they were shipped.
Parts Used:
-
Robert S. from Stafford, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
15 of 23 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Blown Fuse - Ps1750182
Unscrewed the cover of the microwave replaced the blown fuse with the new fuse, plugged in the microwave and tested all functions and everything worked fine. Thx for quick delivery.
Parts Used:
-
John from Inverness, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
12 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!