Models > 58075251900

58075251900 Kenmore Air Conditioner - Overview

Sections of the 58075251900

[Viewing 5 of 5]
Keep searches simple, eg. "belt" or "pump".
Pipe,Drain – Part Number: 3H02773A
Pipe,Drain
PartSelect #: PS3522758
Manufacturer #: 3H02773A
$9.83
  In Stock
FAN,AXIAL – Part Number: 5900A10011D
FAN,AXIAL
PartSelect #: PS12747825
Manufacturer #: 5900A10011D
$104.79
  Special Order
CAP – Part Number: 4H01004B
CAP
PartSelect #: PS3635851
Manufacturer #: 4H01004B
$8.83
  Special Order
Thermistor,NTC – Part Number: 6323A20012C
Thermistor,NTC
PartSelect #: PS3528997
Manufacturer #: 6323A20012C
$10.37
  Special Order
Panel,Control – Part Number: 3720A10112A
Panel,Control
PartSelect #: PS3521457
Manufacturer #: 3720A10112A
$22.10
  Special Order
Supporter – Part Number: 4800A20001A
Supporter
PartSelect #: PS3523739
Manufacturer #: 4800A20001A
$20.63
  Special Order
PCB Assembly,Main – Part Number: EBR39283903
PCB Assembly,Main
PartSelect #: PS3533821
Manufacturer #: EBR39283903
$113.42
  Special Order
Shroud – Part Number: 4998A10035A
Shroud
PartSelect #: PS3525405
Manufacturer #: 4998A10035A
$37.27
  Special Order
Motor,AC – Part Number: 4681A20043K
Motor,AC
PartSelect #: PS3523174
Manufacturer #: 4681A20043K
$336.02
  Special Order
Capacitor,Film,Box – Part Number: 0CZZA20007A
Capacitor,Film,Box
PartSelect #: PS3517203
Manufacturer #: 0CZZA20007A
$66.25
  Special Order
REMOTE CONTROLLER ASSEMB – Part Number: 6711A20066L
REMOTE CONTROLLER ASSEMB
PartSelect #: PS3636484
Manufacturer #: 6711A20066L
$54.91
  Special Order
Filter Assembly,Air Cleaner – Part Number: 5231A20027A
Filter Assembly,Air Cleaner
PartSelect #: PS3527546
Manufacturer #: 5231A20027A
$25.52
  Special Order

Questions And Answers for 58075251900

Be the first to ask our experts a question about this model!

Common Symptoms of the 58075251900

[Viewing 2 of 2]
Noisy
Fixed by
these parts
Fixing Fixing
Show All
Does not shut off
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
accumulated condensation caused condenser fan failure
Pull the unit out of cabinet. Remove the brace between the blower housing and the condenser frame. Remove the screws securing the the condenser coil to the base and carefully lift and angle it just enough for the broken fan to clear ( be very careful with the refrigerant lines ). Slide the new fan back on the shaft and secure with the spring clamp. I used a pair of vice grips to compress the clamp, but be very careful because the clamp can exit the pliers, if the jaws are not perpendicular to the clamp. If you live in a area with high humidity remove the rubber plug at the back of the unit or the condensation will break your new fan. This fan needs some changes in design because the condensation puts too much stress on the plastic that contacts the motor shaft - some metal between shaft and the blades would help.
Parts Used:
FAN,AXIAL CLAMP,SPRING
  • Sam from MCQUEENEY, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
15 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Fan
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed the retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
Parts Used:
FAN,AXIAL
  • April from EASLEY, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad thermistor
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from the grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
Parts Used:
Thermistor,NTC
  • Cindy from Baltimore, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.