Models > 253859411

253859411 Kenmore Dehumidifier - Overview

Sections of the 253859411

[Viewing 4 of 4]
Keep searches simple, eg. "belt" or "pump".
Red Indicator Light Lens – Part Number: 318250801
Red Indicator Light Lens
PartSelect #: PS2349641
Manufacturer #: 318250801
$4.20
  On Order
Compressor Start Relay – Part Number: 216594300
Compressor Start Relay
PartSelect #: PS426380
Manufacturer #: 216594300
$33.65
  In Stock
Float – Part Number: 5303306080
Float
PartSelect #: PS464564
Manufacturer #: 5303306080
$68.02
  Special Order
Humidistat Control – Part Number: 5303296823
Humidistat Control
PartSelect #: PS462294
Manufacturer #: 5303296823
This control needs to be replaced if the dehumidifier won't shut off.
  No Longer Available
SCREW – Part Number: 5303007620
SCREW
PartSelect #: PS453327
Manufacturer #: 5303007620
$12.29
  Special Order
Auto Shut Off Switch – Part Number: 5308016437
Auto Shut Off Switch
PartSelect #: PS474326
Manufacturer #: 5308016437
  No Longer Available
ESCUTCHEON-DIAL PLATE – Part Number: 3016965
ESCUTCHEON-DIAL PLATE
PartSelect #: PS433247
Manufacturer #: 3016965
  No Longer Available
FRONT – Part Number: 3016966
FRONT
PartSelect #: PS433248
Manufacturer #: 3016966
  No Longer Available
CAPILLARY TUBE – Part Number: 3001745
CAPILLARY TUBE
PartSelect #: PS432061
Manufacturer #: 3001745
  No Longer Available
BRACKET-SHUT OFF SWITCH – Part Number: 3016969
BRACKET-SHUT OFF SWITCH
PartSelect #: PS433251
Manufacturer #: 3016969
  No Longer Available
STRAINER – Part Number: 3012363
STRAINER
PartSelect #: PS432456
Manufacturer #: 3012363
  No Longer Available
CORD-ELECTRICAL SERVICE – Part Number: 3015166
CORD-ELECTRICAL SERVICE
PartSelect #: PS432664
Manufacturer #: 3015166
  No Longer Available

Questions And Answers for 253859411

Be the first to ask our experts a question about this model!

Common Symptoms of the 253859411

[Viewing 2 of 2]
Won’t start
Fixed by
these parts
Fixing
Show All
Will Not Start
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The compressor would not run.
I removed the cover, used a multimeter to test the compressor circuit, and found the compressor start relay to be defective.
Ordered a new one and installed it when it arrived.
Parts Used:
Compressor Start Relay
  • Linda from Gurnee, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor was short cycling
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work" since that would be the most common reason and it was not a very expensive part.
Parts Used:
Compressor Start Relay
  • Sherman from Tuttle, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would run continuously and not shut off
Removed the front cover and then the humidistat from the bracket. Two push on wire connectors and then reversed. Very straightforward and excellent part matching. Given the prices for new dehumidifiers it was great to breathe life back into this unit which does its job well. Thanks for the easy to use web site and fast fast service!
Parts Used:
Humidistat Control
  • Jonathan from New Oxford, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!