When powered off, the unit made a growling/rumbling sound that I believe was the condenser. When powered on, the thermometer was not functioning as the unit continued to run making the room colder and colder.
Essentially a plug and play repair by removing the old pc board found inside the unit and replacing it. It’s inside a metal box behind the faceplate of the air conditioner. Many things attached to this board so be sure to replace the connections exactly. I took several pictures prior to disconnecting for reference.
Parts Used:
-
Frank from RICHMOND, OH
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
5 of 6 people
found this instruction helpful.