Eddie from Lovington, NM
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Socket set
Parts Used:
WP3349019,
285811,
285587
upper agitator not turning
removed agitator top by pulling up with hands. Removed inner agitator seal body by grasping with pliers and pulling up. Used 7/16 socket with extra extension to remove top agitator retension bolt. Removed top agitator body and thrust spacer by lifting off of agitator base. Assembled dogs on body as shown in instructions. Replaced thrust spacer on top of agitator base. Installed upper agitator body. Placed dog body inside upper agitator. Placed small piece of paper over 7/16 socket and forced bolt into socket. This held bolt in upright position as I replaced it down inside the upper agitator body and dog assembly with the long extensions. Replaced O-ring on inner agitator seal body and replaced into the upper agitator body using the long extensions to tap it into place. Pressed top agitator cap onto top of upper agitator body. All done. The agitator repair kit purchased had a thrust spacer in it but was not the correct one for my model so I purchased the correct spacer separate. The website is great because it shows the parts in detail so you can take your time and get the proper parts first time, everytime.
45 of 1079 people found this instruction helpful.