Bad door switch and divide
3 of 6 people
found this instruction helpful.
-
Robert from COLORADO SPGS, CO
- Easy
- 30 - 60 mins
-
Screw drivers
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry
... Read more
up. Removing grnd wires helps
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Broken Glass Cooking Tray
2 of 3 people
found this instruction helpful.
-
Gloria from ROSSFORD, OH
- Very Easy
- Less than 15 mins
Placed the new tray into the oven.
Was this helpful?
Thank you for voting!
Just needed to replace the Wave Guide cover
2 of 3 people
found this instruction helpful.
-
Henry from Roseland, NJ
- Really Easy
- Less than 15 mins
-
Screw drivers
Unscrewed the screw, removed old cover, place new cover in place and re-inserted the scrw.
Was this helpful?
Thank you for voting!
The Door Latch on the Avantium Microwave Oven
2 of 3 people
found this instruction helpful.
-
Sherman from Memphis, TN
- Easy
- Less than 15 mins
I removed the door, by taking off the grill at the top. Then, take the puddy knife and screw driver and pry the facing off of the door. Please remember to be very careful because this is a sensitive piece. This is the most difficult part. It is a piece of cake after this. This should take about 15 minutes from beginning to end.
Was this helpful?
Thank you for voting!
Door handle latch
2 of 3 people
found this instruction helpful.
-
Karen from Bend, OR
- A Bit Difficult
- Less than 15 mins
-
Screw drivers
We opened the microwave door and essentially with a straight screwdriver worked to "pop" the plastic frame off of the door. We tried to be less aggressive in our efforts and this paid off since we didn't break anything! The area we needed to work on was now exposed to put the new latch in. It took 2 hands rather than 3 to get the new latc
... Read more
h attached and then wah-lah, It was done! Microwave works perfectly now. Great alternative to buying a new microwave!
Read less
Was this helpful?
Thank you for voting!
Microwave would not heat. Convection still worked.
1 person
found this instruction helpful.
-
Stacie from Granbury, TX
- Really Easy
- Less than 15 mins
-
Screw drivers
I verified I had 120 volts going into transformer when the microwave was supposed to be running. The capacitor and HV diode both tested good. Be sure to discharge the capacitor before working in this area. This isolated trouble to either the transformer or magnetron. The windings of the transformer measured good. So ordered a magnetron. I
... Read more
t was very easy to swap. There were 4 screws and one connector. This fixed our microwave.
Read less
Was this helpful?
Thank you for voting!
The door latch broke.
1 person
found this instruction helpful.
-
Michael from WANTAGH, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
It was really easy. I am not a handy person but I followed a video and got it done quite quickly. It saved me a lot of money. The local appliance repair service charges a minimum of $75 just for the visit plus parts.
Was this helpful?
Thank you for voting!
vent cover broke
4 of 10 people
found this instruction helpful.
-
robert from philadelphia, PA
- Really Easy
- Less than 15 mins
-
Screw drivers
two screws out two screws in done in seconds
Was this helpful?
Thank you for voting!
Latch for door broken
1 person
found this instruction helpful.
-
Steven from TAMPA, FL
- Really Easy
- Less than 15 mins
Unplug power source.
Took off plastic panel partially on inside of door with door on its hinge.
Removed latch and spring.
Reinstalled new latch new spring (new part)
Reattached plastic panel to door.
Plug in power.
Took off plastic panel partially on inside of door with door on its hinge.
Removed latch and spring.
Reinstalled new latch new spring (new part)
Reattached plastic panel to door.
Plug in power.
Was this helpful?
Thank you for voting!
burned wave guide cover
1 person
found this instruction helpful.
-
Edward from ANTIOCH, IL
- Very Easy
- Less than 15 mins
-
Screw drivers
remove with phillips screwdriver. insert 3 corners in to slots and insert and tighten screw.
Was this helpful?
Thank you for voting!
door latch broken
1 person
found this instruction helpful.
-
Loretta from PRT JEFFERSON, NY
- Very Easy
- Less than 15 mins
removed broken latch connected to existing spring done in less than two minutes works better than new
Was this helpful?
Thank you for voting!
Lawn mower would not start
2 of 4 people
found this instruction helpful.
-
Lorraine from MIDDLETOWN, NY
- Very Easy
- Less than 15 mins
-
Screw drivers
removed cover over motor blew it out of leaves and dust. Removes 4 screws and removed piece ordered. The coil was rusted and not connecting. Changed oiece its working again
Was this helpful?
Thank you for voting!
Light bulb went out
1 person
found this instruction helpful.
-
Judith A from LAKEWOOD, CO
- Very Easy
- Less than 15 mins
-
Screw drivers
Opened the light cover. Removed the old light bulb using a light tug on the old bulb, lined up the new bulb and pushed gently into the socket.
Turned the power back on and the microwave is good to go.
Turned the power back on and the microwave is good to go.
Was this helpful?
Thank you for voting!
Not heat
1 person
found this instruction helpful.
-
Kip from POWELL, OH
- Very Easy
- 15 - 30 mins
-
Screw drivers, Socket set
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this helpful?
Thank you for voting!
M/W would not start. control panel OK
1 person
found this instruction helpful.
-
Jeffrey from FULSHEAR, TX
- A Bit Difficult
- 30 - 60 mins
-
Pliers, Screw drivers
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Was this helpful?