Models > JVM1490B > Instructions

JVM1490B - Instructions

All Instructions for the JVM1490B
61 - 75 of 219
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Halogen light for the Microwave above the stove went out.
Ordered the part. 2 days later part arrives. Took me 30 seconds to install the part. Sorry it was not more eventful.
Parts Used:
Halogen Light Bulb - 120V 20W
  • Darren from Madison, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Opened door to get food put more food in closed door it wouldnt work
Everything worked on the display light inside worked but when you closed the door and set time it would start counting down but not heating nor would the turntable turn. Started reading troubleshooting chart and first thing I did was removed the cover and checked door switches and found primary door switch wasn't working so I ordered a new one installed it and it worked. Anyone doing this has to be very careful because of the stored energy in the capacitor is strong enough to kill.
My micro is only 2 years old so I was hoping it wasn't anything major.
Parts Used:
Primary Door Interlock Switch
  • Henry Totten from GROVES, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Handle Broke off microwave
First I removed the vent on top. 2 screws had to be removed. Once plastic vent was removed I could lift door off. I then placed the door flat on counter top to get to backside of door. With 2 flat screwdrivers I pried apart the Door choke cover carefully as to not break the tabs. Its almost impossible not to break them. Thats why I ordered the replacement part. Good thing. I only broke 1. I could have reused it. However I chose to use the new one. Since handle in incorporated in the door, you have to take the door apart. I purchased the Door choke cover as well as a handle. After you remove the choke cover, remove the 6 or 7 small screws around the inner frame next. Now you can get to the door handle screws. Since the door handle broke off, you need to use needle nose pliers to hold the broken plastic on the outside of the door while unscrewing the inside screw that holds the handle. Once removed. replace the handle. Then carefully put it back the same way you took it apart. It took me about 15 to 20 minutes. Im a Female and thrilled I didn't have to call a repairman and get charged 200+
Parts Used:
Door Choke Cover
  • Dara from Tampa, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door latch arm broken, microwave wont start
This was easier than I had expected. Many of the instructions involved removing the door. I decided to skip this when I found a Youtube video showing that the latch replacement required little disassembly. Here are my steps #1 Open door completely and, if needed, have someone steady it. #2 Using a thin plastic putty knife, gently pry off the plastic fascia from the inside of the door. Try to break as few of the plastic retaining tabs as possible (my total was about 10). #3 Slide the old latch upward and outward towards the outside edge of the door with your putty knife. #4 Remove the old latch and spring. #5 Attach the new spring to the latch and hook it to the retainer on the door. #6 Lift the new latch into place, it will drop into the slots with no or little persuasion. #7 reinstall fascia. #8 "nuke" last night's pizza ;)
Parts Used:
Door Latch Assembly
  • Kent from KANSAS CITY, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
mICROWAVE WOULD NOT HEAT
I REMOVED THE TOP PANEL OF THE MICR0WAVE AND THEN REMOVED ONE SCREW TO REMOVE THE CONTROL PANEL. rEMOVED OLD SWITCH. SNAPPED IN NEW SWITCH AND CONNECTED WIRE. REPLACED CONTROL PANEL AND UPPER PANEL.
Parts Used:
Primary Door Interlock Switch
  • Peter from Bessemer, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
latch broke,bulb out
followed instructions posted on line.very good service .parts arrived in a speedy manner and were a perfect fit.
Parts Used:
Halogen Light Bulb - 120V 20W Door Latch Assembly
  • James from Sandown, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Halogen nite light bulbs had burned out
Parts arrived on the morning of the second day (Saturday) to my pleasant surprise. I opened the nite light access door with a screw driver. Inserted the 2 bulbs without touching the outside of the halogen bulbs. Checked that the bulbs did work and closed the access door. The entire process went quickly and posed very little difficulty.
Parts Used:
Halogen Light Bulb - 120V 20W
  • Thomas from Berwick, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both undercabinet light bulbs blown
1. Open the cover over light bulbs with screwdriver.
2. Pulled out blown bulbs.
3. Inserts new bulbs from Partselect.
4. Tested new bulbs
5. Closed the cover over light bulbs with scvrewdriver.
6. Threw out old bulbs and packaging material.

Now, was that easy or what!
Parts Used:
Halogen Light Bulb - 120V 20W
  • pete from roslyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
old rack holder melted
scape melted plastic off of oven wall. apply pliers to melted plastic, pinch plastic, and turn one quarter turn and remove. grab new rack holder with pliers, insert into hole and twist one-quarter turn
Parts Used:
Microwave Holder
  • Rand from Las Vegas, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Installing New Microwave
Required removing the old unit and disconnecting the exhaust ductwork and drilling new holes for attachment to the cabinet
Parts Used:
Mounting Plate Assembly
  • Tom from Carrollton, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old wave guide cover deteriorated from cleaning
Removed one phillips head screw, removed old cover, then replaced new cover and screw. Very easy and Parts Select made it happen. Will deal with them again. Thanks Parts Select.
Parts Used:
Wave Guide Cover
  • Larry from Colbert, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Origional wave guide cover fell apart from harsh cleaners
Removed one Phillips screw, installed new wave guide cover, secured with phillips screw. Done
Parts Used:
Wave Guide Cover
  • Joseph from Staten Island, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Glass tray somehow got a nick in the edge, a few days later it split while in use.
Another company said the new plate would arrive in mid-March, this company seemed to be faster so ordered the tray here, and it came in less than a week. I put the turn button back in the center hole, set the wheeled ring on the bottom of the oven, fitted the new glass tray onto the turn button.
Parts Used:
Glass Cooking Tray
  • Delores from Portland, OR
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light burned out
removed screw that holds glass for light and replaced bulb.
Reinserted screw that holds glass.

Only down side was cost to ship small bulb.
Parts Used:
Halogen Light Bulb - 120V 20W
  • James from Orient, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the turn table no turn and no heat the food. but the bottom oven worked
well I unplugged the microwave one day prior to working on it. shock precaution smart way to do this job. very easy pullout the screws behind the unit pull off the outer casing. minor screws inside the unit you have to remove a couple things out of the way. unplug the magnetron and remove first gives you more room to work on the side panel to replace the micro switches. I only replaced one the bottom micro switch. only one bad, but since I was in there I clean the bulb and changed the magnetron any ways. I read other reviews and made my choice to do so. it works perfectly now. Thanks PartSelect for having parts.
Parts Used:
Magnetron Micro Switch
  • mark from SANBORN, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!