Pantry Drawer Cover keeps falling off, not held in place by End Cap Kit
1 person
found this instruction helpful.
-
Gerald from TANEYTOWN, MD
- Really Easy
- Less than 15 mins
-
Nutdriver
I removed the 2 crisper drawers and the glass shelf directly above the Pantry Drawer. Removed the Pantry Drawer and Pantry Drawer cover so you have easy access to the Right-Hand End Cap. On the right-hand End Cap, there are 2 screws which hold the End Cap in place, use a 1/4 inch driver to unscrew the screws from the front of the cabine
... Read more
t on the End Cap and half-way in of the cabinet, leave the screws in their holes in the End Cap. Lift gently to get off a small plastic pin, and move the End Cap away from the Cabinet. You don't need to completely pull the End Cap out of the cabinet, it'll move more like a door opening. Place 2 washers on each screw and gently put the End Cap back into place, being careful NOT to jostle too much so the washers don't fall off the screws. You will need to gently lift the End Cap back in to place over the plastic pin. Hand-tighten the screws back into place with the 1/4 in driver. Remount the Pantry Drawer on the sliders. When you go to install the Pantry Drawer Cover, you will need to gently push on one of the pins to get the cover back into place. Put glass and crisper drawers back into place.
Test by gently pulling on the Pantry Drawer. If properly mounted, the pins will extend fully into the Cover and will keep it secure when opening the Pantry Drawer.
Test by gently pulling on the Pantry Drawer. If properly mounted, the pins will extend fully into the Cover and will keep it secure when opening the Pantry Drawer.
Read less
Was this helpful?
Thank you for voting!
defrost light on,not getting cold enough
1 person
found this instruction helpful.
-
Amrat from Pomona, CA
- Really Easy
- 30 - 60 mins
-
Screw drivers
remove all tray,remove back panel,cut out out old heater adn replace with new heatger,refitted back panel and alll tray.
Was this helpful?
Thank you for voting!
Refrigerator and freezer not cooling as required, compressor running continually
1 person
found this instruction helpful.
-
Jack D from CLEBURNE, TX
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Turned refrigerator and freezer controls to off, removed icemaker bin, unplugged icemaker plug and removed two screws holding icemaker in place and removed icemaker. removed screws holding auger motor and freezer compartment light plate, unplugged and set aside. Remover screws holding freezer coil cover in place and removed cover. Allowed
... Read more
coils to defrost completely and then removed screws that hold the two defrost heater coil mounting plates in place, unplugged the two wires that connect the defrost heater coils to the connector block that is located above the freezer coil. Remove the entire defrost heater by working the connecting wires out from along side the freezer coil. Remove the clips that hold the old defrost heater elements to the mounting plates. Install new heating elements into the two mounting plates with the clips. Reinstall the two mounting plates to brackets on freezer coil and reinstall connecting wiring up to connector block and reconnect them. Reinstall freezer coil cover, icemaker auger motor and freezer compartment light plate, and icemaker and bin to complete job. Due to the confined space in the freezer compartment, reinstalling the freezer coil cover and light plate was difficult as I could only use one arm at a time resulting in many dropped screws.
Read less
Was this helpful?
Thank you for voting!
Defrost Heater
1 person
found this instruction helpful.
-
RICHARD from SPRINGFIELD, MI
- Really Easy
- 30 - 60 mins
-
Nutdriver
it went good
Was this helpful?
Thank you for voting!
original motor stopped
2 of 4 people
found this instruction helpful.
-
Paul from Lowell, MI
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Socket set
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this helpful?
Thank you for voting!
Condenser Fan Failure
2 of 5 people
found this instruction helpful.
-
Al from Tonka Bay, MN
- Easy
- 30 - 60 mins
-
Socket set
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great
... Read more
!
Read less
Was this helpful?
Thank you for voting!
cooling fan quit
1 of 2 people
found this instruction helpful.
-
George from Belhaven, NC
- Easy
- 30 - 60 mins
-
Nutdriver
Ordered new fan motor on line took out old motor and replaced with new one
Was this helpful?
Thank you for voting!
freezer and food section too warm
1 of 2 people
found this instruction helpful.
-
William from Milford, MA
- Easy
- 30 - 60 mins
-
Socket set
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Was this helpful?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
1 of 2 people
found this instruction helpful.
-
Kevin from COVINGTON, LA
- Really Easy
- Less than 15 mins
-
Nutdriver, Pliers
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this helpful?
Thank you for voting!
unit would not freeze
1 of 2 people
found this instruction helpful.
-
Johnnie from Saginaw, MI
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Screw drivers
I removed all covers then removed screws from element and disconnected wires and removed it.
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
Was this helpful?
Thank you for voting!
Motor noise while running and clicking when shutting off
1 of 2 people
found this instruction helpful.
-
Curtis from Sedona, AZ
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this helpful?
Thank you for voting!
fan motor had gone bad
1 of 2 people
found this instruction helpful.
-
william from whitwell, TN
- Easy
- 30 - 60 mins
-
Screw drivers, Socket set, Wrench set
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
Was this helpful?
Thank you for voting!
Freezer and Frig was not cooling down. The freezer side was all froze up on the coils.
1 of 3 people
found this instruction helpful.
-
David from Kalamazoo, MI
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
Unplug the Frig and left the freezer side total defrost. Mine was so frozen up, it took about 6 hours with the door open. I had a towel in the botton to catch all the water and ice that fell.
Removed all the shelving units. There are 3 screws that hold the ice maker in place. Loosen the 2 screws above the ice maker about 3 ... Read more or so turns. Then remove the screw under the ice maker completely. Then lift the ice maker off of the 2 screws that you just loosened. Then with a small flat blade screwdriver, push the plastic clip that holds the connector of wires that plug into the ice maker.
Then remove the screws that hold the back plastic cover that conseals the coil.
Now you should see the coils. There is one heater unit in the middle and one at the botton. There is a screw on each side of the heater unit that you need to take out. They are screwed into a metal bracket that is part of the coil system. Once the screws are removed, you simply remove the heater units. They are plugged in at the top of the coil system on a circuit board. Unplug them from there, (one of the spades connector was slightly bigger then the other, so I new where to plug them back in). Fish all the wire and heater untis out and you are ready to re-oinstall the new units.
Getting the wires back up through the coils was tricky, but I was able to do it.
The hardest thing was working inside the freezer unit. It is not very wide and was sometimes hard to get both hand inside to work.
Removed all the shelving units. There are 3 screws that hold the ice maker in place. Loosen the 2 screws above the ice maker about 3 ... Read more or so turns. Then remove the screw under the ice maker completely. Then lift the ice maker off of the 2 screws that you just loosened. Then with a small flat blade screwdriver, push the plastic clip that holds the connector of wires that plug into the ice maker.
Then remove the screws that hold the back plastic cover that conseals the coil.
Now you should see the coils. There is one heater unit in the middle and one at the botton. There is a screw on each side of the heater unit that you need to take out. They are screwed into a metal bracket that is part of the coil system. Once the screws are removed, you simply remove the heater units. They are plugged in at the top of the coil system on a circuit board. Unplug them from there, (one of the spades connector was slightly bigger then the other, so I new where to plug them back in). Fish all the wire and heater untis out and you are ready to re-oinstall the new units.
Getting the wires back up through the coils was tricky, but I was able to do it.
The hardest thing was working inside the freezer unit. It is not very wide and was sometimes hard to get both hand inside to work.
Read less
Was this helpful?
Thank you for voting!
check valve O ring was badly deteriorated - spraying water out at O ring
2 of 6 people
found this instruction helpful.
-
bernard from INDIAN TRAIL, NC
- Easy
- 15 - 30 mins
-
Socket set
The description of the parts package on your website did not appear to be in proper (size) scale However, after following a Youtube video, I was then able to decipher what parts went where to be sure I was ordering the correct parts that I needed. Parts were shipped promptly and I found that replacing just the check valve o rings and sea
... Read more
ts, it cured the problem without having to use the other parts that came with the kit package. Would definitely order from this site again. BL NC
Read less
Was this helpful?
Thank you for voting!
missing clips
2 of 6 people
found this instruction helpful.
-
Gaylon from Auburndale, FL
- Really Easy
- Less than 15 mins
-
Screw drivers
I had to find a couple screws that would match the clips and kickplate. I screwed on the clips. The kickplate snapped on perfectly.