- Home
- ZISS360NRSS
- Instructions
ZISS360NRSS General Electric Dryer - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people
found this instruction helpful.
-
Terry from Simi Valley, CA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s
... Read more
o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Read less
Was this helpful?
Thank you for voting!
my refrgerator stopped cooling and freezing
12 of 12 people
found this instruction helpful.
-
Mike from Aguilar, CO
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
Take the cardboard grill off the bottom of the back it is held on with 5-6 hex head screws. Located the voltage inverter on the tank. It's on the bottom left of the refrigerator. Removed the screw that holds it in place.Remove the jumper wires at the quick connect. Rotate the voltage inverter and removed it. Check the voltage at the plug
... Read more
in going to the voltage Inverter. It should be 115-125 volts. Plug in the voltage inverter to the Quick connect away from the tank check the voltage on the side that would be connected to the tank. If both sides don't read at least 115 volts the inverter is bad. Order a new on and reinstall in the reverse order.
Read less
Was this helpful?
Thank you for voting!
Would not heat up
13 of 15 people
found this instruction helpful.
-
Marty from BOX SPRINGS, GA
- Really Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Took the few screws out replaced the part then put it back together.
Was this helpful?
Thank you for voting!
Existing light switch was hard to remove.
14 of 19 people
found this instruction helpful.
-
Stephen from Jupiter, FL
- A Bit Difficult
- Less than 15 mins
-
Screw drivers
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this helpful?
Thank you for voting!
Dryer was making noise
12 of 14 people
found this instruction helpful.
-
Maurice from MINERAL SPGS, AR
- Really Easy
- 15 - 30 mins
-
Screw drivers
Took the top and front end of the dryer off. Took the old slider spacers off and installed the new ones. I replaced all four of them even though only two was bad. While I had the dryer open I decided to use my shop vac to clean up the lint that had accumulated there. Replaced the front and the lid plugged it up, hit the start no noise j
... Read more
ust like new.
Read less
Was this helpful?
Thank you for voting!
First, no heat; then, no run
12 of 14 people
found this instruction helpful.
-
Hector from SAN PEDRO, CA
- A Bit Difficult
- More than 2 hours
-
Nutdriver, Screw drivers
Washer/dryer belongs to a friend. Originally, the problem was that the dryer wouldn’t heat, so I opened it up, and removed the drum thinking it might be the heating element. It wasn’t, and the ohm reading confirmed this. It turned out to be a burnt wire connector to the element ( unknown to me, and found out later, was that the start swi
... Read more
tch had remained continuously in the down position because the switch was pressed too far down and thus remained locked “on” in place under the surrounding cabinet frame. This, in my opinion, caused for a continual call for heat and thus burnt the wire.)
I replaced the burnt wire/connector and reassembled. Now the dryer would heat, but would only run if the start button was continually depressed. Let go of the button, and the dryer stopped.
Repair pros suggested a new start switch. I bought a new start switch along with a new interlock switch (it basically shuts off dryer if belt breaks because lack of a belt releases pressure on the pulley that keeps switch depressed.) Apparently they can go bad, too.
It turns out neither of these switches were bad. Instead, upon further inspection, after the first installation of the drum belt, the L-shaped bracket which holds the pulley for belt tension became dislocated from its correct position and was not allowing for the depression of the interlock switch, causing the dryer to “read” broken belt, and thus, not run.
I loosened the motor bracket to allow placing the bracket in the correct position. Reassembled and all was good.
PSA - almost every sheet metal edge is razor sharp.
In the process of returning parts. Now in the process of returning parts.
I replaced the burnt wire/connector and reassembled. Now the dryer would heat, but would only run if the start button was continually depressed. Let go of the button, and the dryer stopped.
Repair pros suggested a new start switch. I bought a new start switch along with a new interlock switch (it basically shuts off dryer if belt breaks because lack of a belt releases pressure on the pulley that keeps switch depressed.) Apparently they can go bad, too.
It turns out neither of these switches were bad. Instead, upon further inspection, after the first installation of the drum belt, the L-shaped bracket which holds the pulley for belt tension became dislocated from its correct position and was not allowing for the depression of the interlock switch, causing the dryer to “read” broken belt, and thus, not run.
I loosened the motor bracket to allow placing the bracket in the correct position. Reassembled and all was good.
PSA - almost every sheet metal edge is razor sharp.
In the process of returning parts. Now in the process of returning parts.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
latch on door broken, dryer could not function
19 of 36 people
found this instruction helpful.
-
blanche from Delray Beach, FL
- Really Easy
- Less than 15 mins
I just pressed the latch with my thumb, the latch went in, and voila....job done. Thank you
Was this helpful?
Thank you for voting!
slow water flow in dispenser
14 of 21 people
found this instruction helpful.
-
dwight from phoenix, AZ
- Really Easy
- Less than 15 mins
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Was this helpful?
Thank you for voting!
Dishwasher would not turn on.
10 of 10 people
found this instruction helpful.
-
Patrick from QUINTON, VA
- Really Easy
- 30 - 60 mins
-
Screw drivers
There are 2 switches that should be pressed in when you move the handle to lock door, the switches usually go bad with time. Just take the six screws off on the inside of door, then remove screw on the underneath part of handle. The switches are located on the top part under a piece of 1 inch metal plate held in by a screw, remove that an
... Read more
d you'll see the 2 switches, test the button on each one to see if it goes in and out, you'll hear the click to. Just unplug bottom first then the top if you need to replace the top one. Thats it.
Read less
Was this helpful?
Thank you for voting!
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
16 of 28 people
found this instruction helpful.
-
Laura from Manchester, NH
- Really Easy
- 15 - 30 mins
-
Screw drivers
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this helpful?
Thank you for voting!
refrigerator and freezer stopped working
9 of 9 people
found this instruction helpful.
-
mike from Aguilar, CO
- Really Easy
- 30 - 60 mins
-
Nutdriver
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what
... Read more
the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Read less
Was this helpful?
Thank you for voting!
Switchlight was broken on tennant's refridge
10 of 12 people
found this instruction helpful.
-
Mark from Somers Point, NJ
- Easy
- Less than 15 mins
-
Pliers, Screw drivers
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapp
... Read more
ed the new switch into place.
10 minutes total.
10 minutes total.
Read less
Was this helpful?
Thank you for voting!
mullion was rusted and the gasket torn after only 3 years
14 of 24 people
found this instruction helpful.
-
lara from NORTH AUGUSTA, SC
- Very Difficult
- More than 2 hours
-
Screw drivers
Instruction link would not work but removing the 4 screws and unplugging the part was fairly easy. The hinges on the new part are very stiff and made it difficult to close the door. then the ice maker stopped working and the ice melted all over the floor. I had to fish the old rusty part out of the garbage and reinstall it. the ice ma
... Read more
ker once again functioned properly. The replacement gasket is completely different from the original. the original holds its shape when removed, the replacement does not hold its shape at all. It is floppy, will mot lay smoothly and does not seal the door.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
dryer would not stay on so I ordered a button, but wrong part.
17 of 33 people
found this instruction helpful.
-
Linda from FITCHBURG, MA
- Really Easy
- 1- 2 hours
First I called to get help with the right part and they told me I needed the pus-to-start-switch. It came in and I called my handyman Ed to install it. I am happy with your service. I dont install but just got the part in.
Was this helpful?
Thank you for voting!
broken latch
15 of 28 people
found this instruction helpful.
-
james from bainbridge island, WA
- Really Easy
- Less than 15 mins
snapped in new latch
Was this helpful?
Thank you for voting!