No Power
7 of 14 people found this instruction helpful.
  • Florentino from West Palm Beach, FL
  • A Bit Difficult
  • 15 - 30 mins
  • Screw drivers
Check with Digital meter all connections.Find a Thermostat open loop.This thermostat is near the Megatron .
Was this helpful?
Thank you for voting!
mICROWAVE WOULD NOT HEAT
5 of 8 people found this instruction helpful.
  • Peter from Bessemer, MI
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I REMOVED THE TOP PANEL OF THE MICR0WAVE AND THEN REMOVED ONE SCREW TO REMOVE THE CONTROL PANEL. rEMOVED OLD SWITCH. SNAPPED IN NEW SWITCH AND CONNECTED WIRE. REPLACED CONTROL PANEL AND UPPER PANEL.
Was this helpful?
Thank you for voting!
Replaced under hood surface light bulb
4 of 5 people found this instruction helpful.
  • Dottie from NEW MILFORD, CT
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Very easy to replace. This replacement part is the perfect fit for my microwave since the original part has been discontinued. It does have the night light and bright light feature.
Was this helpful?
Thank you for voting!
Halogen nite light bulbs had burned out
4 of 5 people found this instruction helpful.
  • Thomas from Berwick, PA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Parts arrived on the morning of the second day (Saturday) to my pleasant surprise. I opened the nite light access door with a screw driver. Inserted the 2 bulbs without touching the outside of the halogen bulbs. Checked that the bulbs did work and closed the access door. The entire process went quickly and posed very little difficulty.
Was this helpful?
Thank you for voting!
Both undercabinet light bulbs blown
5 of 8 people found this instruction helpful.
  • pete from roslyn, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
1. Open the cover over light bulbs with screwdriver.
2. Pulled out blown bulbs.
3. Inserts new bulbs from Partselect.
4. Tested new bulbs
5. Closed the cover over light bulbs with scvrewdriver.
6. Threw out old bulbs and packaging material.

Now, was that easy or what!
Was this helpful?
Thank you for voting!
old rack holder melted
3 of 3 people found this instruction helpful.
  • Rand from Las Vegas, NV
  • Really Easy
  • Less than 15 mins
  • Pliers
scape melted plastic off of oven wall. apply pliers to melted plastic, pinch plastic, and turn one quarter turn and remove. grab new rack holder with pliers, insert into hole and twist one-quarter turn
Was this helpful?
Thank you for voting!
Installing New Microwave
5 of 9 people found this instruction helpful.
  • Tom from Carrollton, TX
  • Really Easy
  • 1- 2 hours
  • Screw drivers
Required removing the old unit and disconnecting the exhaust ductwork and drilling new holes for attachment to the cabinet
Was this helpful?
Thank you for voting!
Micro was not producing heat.
3 of 4 people found this instruction helpful.
  • Sal from Center Moriches, NY
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
Removed unit from above range. (A two person task.) Removed display panel, disconnecting wires from plugins. Removed outer cover to access magnetron. Used camera to take photos before disconnecting other wires. Replaced magnetron and reconnected wires, double checking with photo. Tested prior to reinstalling. It works fine.
Was this helpful?
Thank you for voting!
light burned out
5 of 10 people found this instruction helpful.
  • James from Orient, OH
  • Really Easy
  • Less than 15 mins
  • Screw drivers
removed screw that holds glass for light and replaced bulb.
Reinserted screw that holds glass.

Only down side was cost to ship small bulb.
Was this helpful?
Thank you for voting!
Too dirty to clean, bought new parts.
3 of 4 people found this instruction helpful.
  • Debora from Saugus, MA
  • Really Easy
  • Less than 15 mins
I had already removed the old grease filters. Unwrapped the new grease filters and popped into place. No tools were necessary.
Was this helpful?
Thank you for voting!
Old screw holles broke off
3 of 5 people found this instruction helpful.
  • Kelly from HOLLADAY, UT
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Put the replacement piece in and screwed it tight
Was this helpful?
Thank you for voting!
Halogen lamps did not light-burned out
3 of 5 people found this instruction helpful.
  • dennis from harbor springs, MI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Removed the light cover screw with a Phillips screwdriver. Removed the lamps from the packaging just enough to free up the 2 prongs for fitting in the socket. Make sure the power is in the "off position". Install the bulbs one at a time by lining up the 2 sockets (Very important not to touch the halogen bulb glass surface while installing them). Energize the light switch to check operation of the new bulbs.
Was this helpful?
Thank you for voting!
The power was on but the Microwave would not start.
3 of 5 people found this instruction helpful.
  • William from KINGMAN, AZ
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers
This is an above the range microwave, use 2 people to remove it. I set it on a table and removed the outer cabinet. I then used jumper leads to discharge the capacitor. I removed the control panel (taking a picture to ensure proper wiring on assembly), then I removed the latch board. Once I had the latch board out I removed the monitor sw itch (which is the middle switch) and tested it for continuity. This is a normally closed switch. I tested the other two switches as well and found these (normally open) switches for continuity to be good and the monitor switch to have a short. This switch should show continuity when the door is open and should show no resistance when the door is closed. (Take care removing the switches) After I received the parts I installed them in the new Locker Holder and installed the latch board (ensure to follow the latch board adjustment steps located in the control board). I then attached the wiring to the control board and then plugged in the unit. I tested the unit to ensure it functioned correctly. I then installed the outer cabinet, and then installed the unit above the range (Use 2 people for this process). Overall an easy fix you just need to ensure you follow safety procedures (especially when dealing with capacitors.
Take a lot of pictures of the wiring and of the components and take care with the latch board or you'll have to buy a new one when all you really needed is a monitor switch.
Was this helpful?
Thank you for voting!
Microwave not turning on. All other functions operate
2 of 2 people found this instruction helpful.
  • Tom from DENVER, CO
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switc hes (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Was this helpful?
Thank you for voting!
Microwave stopped working
2 of 2 people found this instruction helpful.
  • Diana from WOODSTOCK, NY
  • Very Easy
  • 30 - 60 mins
To get the microwave out to fix it, Appliance repair man had to dismantle surrounding Cabinetry. It then took him half an hour to replace part. Reassembly took another 45 minutes.
Was this helpful?
Thank you for voting!