Sparking from the magnetron
Symptom: Terrible sparking coming from the right side of the microwave even with nothing in the microwave. The part that was behind the cover was the business end of what I learned was the magnetron,

Repair process: Without appliance repair experience I went onto Google and searched for parts for my model PEB1590DM2WW. I was able to find a great parts schematic on partselect.com. At first I ordered a magnetron and while waiting for the parts to arrive I also learned that the capacitor can also fail easily as described in the other install feedback on the partsselect website. So I ordered a capacitor just in case. These convection microwaves are around $600 new so a $80 in parts is not out of line for 8 years of service.
I installed the magnetron first and turned it on. sparking immediately continued so I quickly shut the unit off. After replacing the capacitor and letting it charge for several minutes before trying to start the microwave cycle was the issue. I choose to leave the replaced magnetron as the original unit was discolored and felt the replacement was inexpensive insurance. I also learned that if the wave guide (which is a plastic/metallic composite material) that covers the opening to the magnetron is burnt or has metal melted to it as mine did it will act similar to the microwave having metal inside the enclosure and will continue to spark and basically melt the wave guide further. Replacing the wave guide was very easy as well.

I am very thankful for the knowledge base and support available from Partselect.com as they made this repair possible on my own. Thank you partselect.com
Parts Used:
Microwave Magnetron
  • Reid from LITTLETON, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace interior bulb
Pretty simple but required buying a set of security bits (#68549) from Harbor Freight for $7.00 to remove the outer cover of my GE JES2051SNSS microwave. At first glance I thought the cover would remove by going towards the front of the microwave, but it ended up just needing a tug to the rear. I like this site because they have pictures of the exploded appliances that show what your getting into.
Parts Used:
Light Bulb - 125V 20W
  • Chris from VIRGINIA BCH, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave does not have power at all, though outlet has power
unplugged power cable / unhooked front vent / unscrew the monitor panel / slide up to dislodge / take the fuse out and put in the new one in / fuse is located right in front of monitor panel once its open might be covered by wirings / you can unpin the cables from the panel to make it easier for you just make sure to put it back properly or you can have somebody hold the panel for you. Installing the fuse is easy waiting for the parts is crazy......
Parts Used:
FUSE
  • Ronie from BRIARWOOD, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Arcing had caused burned turntable and melted connection to sec. motor.
Note: also had to replace turntable. Removed top cover using secure driver set. Placed microwave on it's front, using a soft towel. Removed edge screws from bottom plate (leaving 4 screws in center attached to heavy transformer). Separated bottom plate from body of microwave (leaving transformer wires still attached) exposing Synchronous motor. Removed two screws holding motor and electrical plug. Swapped new motor in its place. Re-attached bottom plate with its screws. Placed microwave onto it normal position. Re-attached top cover with its secure screws. Installed new turntable inside.
Parts Used:
Motor, AC Synchronous
  • John from MOUNTAIN VIEW, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The carousel stopped rotating on my microwave
The carousel stopped rotating on my microwave oven because the plastic assembly that rotated underneath the platter had split at the point where it fit on to the rotating shaft underneath the floor of the microwave. I ordered a new plastic assembly and popped it on to the shaft. Problem solved in less than a minute.
Parts Used:
Rotating Ring Guide
  • William from Washington, DC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken microwave tray
I'm very impressed with the quailty of the product and the shipping speed. I had the new microwave plate in 2 business days. No difficulties with installation, obviously.
Parts Used:
Glass Cooking Tray
  • Kirsten from Menifee, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Opened door to get food put more food in closed door it wouldnt work
Everything worked on the display light inside worked but when you closed the door and set time it would start counting down but not heating nor would the turntable turn. Started reading troubleshooting chart and first thing I did was removed the cover and checked door switches and found primary door switch wasn't working so I ordered a new one installed it and it worked. Anyone doing this has to be very careful because of the stored energy in the capacitor is strong enough to kill.
My micro is only 2 years old so I was hoping it wasn't anything major.
Parts Used:
Primary Door Interlock Switch
  • Henry Totten from GROVES, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave was accidentally overheated and all power was lost.
Since I didn't know if it was the current fuse or the flame sensor, I ordered both parts, and, I had to order the tamper proof torx bits needed to remove the microwave cover ($7.45 on Amazon). Once the cover was off the unit, both parts were easily accessible on top of the oven and were replaced in only a couple of minutes.
Parts Used:
Flame Sensor Thermostat FUSE
  • Charles from PAWLEYS ISL, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
mICROWAVE WOULD NOT HEAT
I REMOVED THE TOP PANEL OF THE MICR0WAVE AND THEN REMOVED ONE SCREW TO REMOVE THE CONTROL PANEL. rEMOVED OLD SWITCH. SNAPPED IN NEW SWITCH AND CONNECTED WIRE. REPLACED CONTROL PANEL AND UPPER PANEL.
Parts Used:
Primary Door Interlock Switch
  • Peter from Bessemer, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The revolving motor would not turn the glass tray
e.g. First I removed the bottom cover. I then removed the two screws that hold the motor in place. I then pulled the motor out about 3 inches and disconnected the two wires...)
I then put the new motor in with the two screws and hooked the wires back up. I then replaced the bottom cover and put the the turn rack and glass tray back in place. Works great.
Parts Used:
MOTOR SYNCHRONOUS
  • Jerry from Plano, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven would not start when closing door.
Removed some cosmetic panels. Removed the assembly with micro switches. Examined the faulty switch by checking the clicking action of switch. Two others were ok by this method. Replaced the switch with new one. Works fine so far. Thanks to web site and YouTube videos.
Parts Used:
Micro Switch
  • Raymond from DEPEW, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No longer rotated item that was being heated.
Removed the old rotating ring guide that was broken on the bottom and replaced with the new part I ordered. Only suggestion is if it doesn't rotate check how you inserted the new part - it has to be a certain way. Works just fine.
Parts Used:
Rotating Ring Guide
  • Janet from BENNINGTON, VT
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the turn table no turn and no heat the food. but the bottom oven worked
well I unplugged the microwave one day prior to working on it. shock precaution smart way to do this job. very easy pullout the screws behind the unit pull off the outer casing. minor screws inside the unit you have to remove a couple things out of the way. unplug the magnetron and remove first gives you more room to work on the side panel to replace the micro switches. I only replaced one the bottom micro switch. only one bad, but since I was in there I clean the bulb and changed the magnetron any ways. I read other reviews and made my choice to do so. it works perfectly now. Thanks PartSelect for having parts.
Parts Used:
Magnetron Micro Switch
  • mark from SANBORN, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not heat and made a buzzing or popping sound
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other and then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.
Parts Used:
Magnetron
  • Thomas from NEWARK, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacing burnt out bulb on microwave
To remove the outer cover of the microwave you have to unscrew 7 or 8 Phillips screws but most of them have "secure" type heads, so you need a driver with a hole in the middle, to fit over the pin on the screw head. I had one of those already, so it wasn't a problem. The metal cover is slid between rubberized strips on the front face of the enclosure and needs to be lifted and tugged out quite firmly in order to release it. Once the cover was removed, the bulb can be seen attached to the main frame of the microwave by a soft metal lug that can be bent back by hand to release the bulb and its integrated holder. The wiring harness simply pulls off of the bulb prongs and there you have the charred remains of the original bulb! I tried every appliance store and hardware store in Bismarck, but nobody had this part. When I typed in the serial number on the bulb, Partselect's site came up with exactly what I needed. Replacement was a simple reversal of the process, making sure not to over-tighten the sheet metal screws on the cabinet. Voila! We have light beams again. Thanks Partselect.
Parts Used:
Light Bulb - 125V 20W
  • Paul from BISMARCK, ND
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.