not cold enough refrig. side
9 of 9 people found this instruction helpful.
  • Ross from River Grove, IL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
These so called factory trained techs, at least the ones that looked at my fridge don't know jack. I explained my problem, they replaced T-Stat refridge side, onother time they replaced door gasket, still not cold enough, found your website,
got all the answers. Ordered and installed,defrost
heater and T stat assy and adaptive d efrost control. Remove shelves freezer side, remove evaporator cover 1/4" nutdriver ,defrost with hair
drier, unsnap elec. connector and relaced part.
The ADC, removed screws mounted on roofside
was able to lower plastic panel enough to unplug
the ADC, it just laid there, removed and replaced.
Don't know which part was bad, but I do know that
they are interconnected, at this point I din't care to defrost manually which I did for the last 7 months.
Thanks for your guidance. USMC Ross
Was this helpful?
Thank you for voting!
Sides and door frames of the refrigerator warm to the touch.
10 of 12 people found this instruction helpful.
  • Dave from Bedford, IN
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
Confirmed the condenser fan was the problem when I noted it was not running when the compressor was on. Removed 3 mounting screws, unpluggede the fan. Removed and replaced the mounted flange(3 screws) and remounted. Plugged in fan and it started running.

Thanks for the diagrams and quick delivery. This is the second repai r on appliances I have made with your parts and probably saved $300-400 in service calls.
Was this helpful?
Thank you for voting!
Refrigerator not cold - ice build up in freezer cabinet
11 of 15 people found this instruction helpful.
  • James from Toluca Lake, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Chronically faulty electronic board in upper right rear of refrigerator compartment - in Maytag and Jenn-Air. Unplug unit. Remove freezer food to ice chest. Remove baskets and shelves, ice hopper and rear lower panel to expose evaporater fins. Defrost with hair dryer and allow all moisture to dry. Then in refrigerator, remove top she lf food. Carefully remove the upper assembly cover by working the plastic down and slide forward to unhook from rear slide attachments - one on each side. This is the hard part of repair.

Then remove screws from rear wall and just behind the lamps to release the whole control assembly. In the rear right corner is the bad board. Unplug and replace with new board. Reassemble the fridge and freezer. Replug unit.
Was this helpful?
Thank you for voting!
Freezer was overfrosting and not defrosting. Frig. was not getting cold.
9 of 9 people found this instruction helpful.
  • Daniel O. from Gilroy, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
This was very easy. I removed all the shelves in the freezer compartment. I removed two nutscrews to remove the back wall. Then I removed the little radiator looking part by removing two more nutscrews. I unplugged the old thermostat assembly and installed the new one exactly like I removed it, then I reversed the procedure to put it all back together. Very easy my wife could have done it. ThANKS!! to Parts Select for the help of all the blogs I read before doing the job.
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
The relay had burnt up.
9 of 10 people found this instruction helpful.
  • Jacob from Glennville, GA
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Pliers
I Removed the two wires from the old relay. I Then pulled the old relay off the compressor. Next, I had to get the overload seperated from the old burnt relay, which took some care not to break. The old relay and overload is in a plastic compartment. Then I followed the directions that came with the new relay. The only confusion came with getting the two wires back onto the terminals of the new relay, mainly because the old relay was burnt so badly I didn't have any idea how it was originally wired. I crossed the two wires on the terminals of the relay. The compressor would click off and on, but would not start blowing cold air. I swapped the wires on the terminals and it started working immediately.
Was this helpful?
Thank you for voting!
refrigerator and freezer not cold enough
8 of 8 people found this instruction helpful.
  • Greg from Williamstown, NJ
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Wrench (Adjustable)
I don't know anything about repairing a refrigerator - I'm a computer tech. I noticed that the outside of the fridge was warm to the touch and the inside was not getting as cold as it should. I took the lower back panel behind the fridge off and noticed that the fan was not spinning. The local parts dealers did not have the condenser fan motor that was needed but they did say that they do go bad. I decided to order one from PartSelect.com and do it myself. Using a 1/4 inch nut driver and a flat head screw driver to pry the old motor out of the casing, I got the job done in about an hour or so. It's a relativly easy job. Besides the ouside panel screws, there's 3 screws on the inside near the fan blades you have to reach in to get. Pop out the whole assembly, unscrew the nut that holds the blades on and pry out the old motor and replace.. Try it yourself and save a couple hundred bucks!
Was this helpful?
Thank you for voting!
Bottom of freezer compartment was icing up/freezer was leaking water
8 of 8 people found this instruction helpful.
  • Jason from Clarkston, MI
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
UNPLUG YOUR FRIDGE BEFORE YOU START> First I removed the shroud covering the lights and controls in the top of the refrigerator side. This was the hardest part, actually. Their are two indentations on the back of the cover and it is really hard to pull that cover off. Anyhow, once you do that, their are two screws, one by each light b ulb in the top of the fridge that need to be removed. Their are also three hex head screws that need to be removed, two in the front corners of the assembly, one in the center, back of the fridge. Take those out and the whole assembly drops down. In the back right had corner of the assembly is the adaptive defrost control. Unplug it and set it aside. Plug the new one in. Put everything back together and you are back in business.
Was this helpful?
Thank you for voting!
didn't eject icecubes
9 of 12 people found this instruction helpful.
  • Ronald from Marion, IL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Was this helpful?
Thank you for voting!
Freezer worked fine but the Refrig. wasn't getting cold
8 of 9 people found this instruction helpful.
  • Lucy from Menifee, CA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
My husband first replaced the Defrost heater and the fridge still didn't stay cold. We had to defrost the freezer once a week and the fridge would stay cold for a few days, but after we replaced the Thermostat Assembly it worked GREAT! Thank you all for your comments and suggestions it saved us hundreds of dollars having to replace an, ot herwise, perfectly fine fridge. Good luck to you if you have this problem, it was sooo fast and easy to replace these parts and totally worth the money.
Was this helpful?
Thank you for voting!
replacing thermostat did not help
10 of 15 people found this instruction helpful.
  • John from Rocky River, OH
  • Difficult
  • More than 2 hours
  • Pliers, Screw drivers, Socket set
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiv er boaed. I turn off manually the icemaker, when needed
Was this helpful?
Thank you for voting!
Ice maker leaked water
10 of 15 people found this instruction helpful.
  • Robert from Pennsylvania Furnace, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Was this helpful?
Thank you for voting!
refrigerator would not cool but freezer worked fine
7 of 7 people found this instruction helpful.
  • sylvia from dawsonville, GA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
I removed the plastic housing inside the top of the rerigerator. Next I removed one hex head screw on the right side that screwed into the back wall using a 1/4 inch nut driver and I removed four hex head screws that screwed up through the temperature control unit into the top. There were two phillips head screws that had to be loosened, but not removed, that also scewed up through the assembly. After the hex head screws were removed, the whole assembly pulls out about an inch then drops down. Once it's down you can remove the adaptive defrost circuit board in the right rear corner of the unit. It's fixed! Thanks
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people found this instruction helpful.
  • Michael from East Meadow, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
Broken Piece
7 of 8 people found this instruction helpful.
  • anthony from georgetown, IL
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
Had to disassemble ice maker to install part. . .
Was this helpful?