Dryer got hot then heat would shut off
6 of 7 people
found this instruction helpful.
-
Douglas from Fernley, NV
- Really Easy
- 30 - 60 mins
-
Nutdriver, Socket set
Sensor is in the front lower left. Gas off, electicity off. Removed two screws for the filter, pry/lifted the top up and taped it too the overhead cabinet, removed two screws inside top of front panel, lifted pandel with door closed staight off. Two screws to remove the flame sensor braket. unplug the old sensor install the new one and r
... Read more
everse everything. With others suggestions I purchased temperature switches etc. but the radiant flame sensor was the problem. I now have some spare switches for future. Excellent company and very quick service. Oh, Sears wanted 200.00 just for the service call, I live rural.
Read less
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people
found this instruction helpful.
-
Carl from RIVERSIDE, CA
- Very Difficult
- More than 2 hours
-
Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!
Freezer making loud whining noise-Fridge not cooling well
7 of 13 people
found this instruction helpful.
-
Dale from Blaine, MN
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Removed the 3 screws in the back of the freezer, pulled back the metal back plate on the freezer. Removed 4 nuts on the plastic housing that holds the fan and pulled the housing down. Disconnected the wires, unscrewed the 2 screws holding the fan to the housing. Replaced old fan motor with new fan motor onto housing just as it was befo
... Read more
re. Reconnected the wires. And tested the motor. Worked great. Re-assembled everything as it was and it was done.
Read less
Was this helpful?
Thank you for voting!
No heat...
5 of 7 people
found this instruction helpful.
-
Charles from Long Beach, CA
- Easy
- 30 - 60 mins
-
Socket set
Removed and replaced both the thermostat sensor and the ignitor. Tested thej dryer and it worked. Replaced the front panel and it was good to go.
Was this helpful?
Thank you for voting!
Making a god awful racket.
5 of 7 people
found this instruction helpful.
-
Michael from Locust Grove, VA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Ok its the garage "adult " Beverage chiller.
Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Was this helpful?
Thank you for voting!
Would not lite
4 of 4 people
found this instruction helpful.
-
RICHARD from LINDSTROM, MN
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
Remove igniter and replaced easy to do
Was this helpful?
Thank you for voting!
Evaporator Fan in Freezer Making Load Noise
4 of 5 people
found this instruction helpful.
-
Ralph from SAINT PAUL, MO
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Removed freezer shelving. Removed 3 shelving brackets (dovetailed) by sliding them up off of the small square mounted on the freezer wall. This was a stumbling block until
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip ... Read more on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip ... Read more on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
Read less
Was this helpful?
Thank you for voting!
Fan motor stopped working.
5 of 8 people
found this instruction helpful.
-
John from Clifton Heights, PA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I first unplugged the unit.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Was this helpful?
Thank you for voting!
nosiy fan operation
4 of 5 people
found this instruction helpful.
-
TOM from GRANVILLE, MA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
most of the time spent on repair was removing the food from freezer compartment other than that removal of a couple screws and disconnecting and reconnecting wires not a huge ordeal
Was this helpful?
Thank you for voting!
Fan was making alot of noise
4 of 6 people
found this instruction helpful.
-
JERRY from ALBION, AL
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers, Socket set
I removed all the shelves and the back shelf hanger. Removed two screws on the back plate.Pulled it out.Removed the screws that hold the fan housing. Pulled it out so I could write down the three wires color and location.Unpluged them.Removed the old fan and installed the new one.and put everthing back together.
Was this helpful?
Thank you for voting!
Noisy freezer evaporator fan motor
4 of 6 people
found this instruction helpful.
-
Lloyd from Long Beach, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
Removed the shelves from the freezer and the brackets holding it along with the covers for the light and plate for the ice maker (we don't have one). Pulled the ground wire from the tab off the port for the ice maker. Removed back plate exposing the fan motor and then the 4 hex screws holding on part #23 of the diagram which the fan mot
... Read more
or is mounted to. Flipped it over, unscrewed the 2 hex screws from the fan motor mounting and removed it. Removed and replaced 3 wire connectors on new fan motor. Installed new fan motor and new grommets but used the old screws because the provided screws were larger. Pushed the new fan on to the motor shaft. Reassembled. Half hour most.
Read less
Was this helpful?
Thank you for voting!
Fan motor
3 of 3 people
found this instruction helpful.
-
Bonnie from DETROIT LAKES, MN
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Remove bottom of freezer by sliding out the gaskets on each side.
Remove back of freezer. 6 screws.
Remove fan cover. 4 screws.
Remove fan. 3 wires to disconnect. 2 screws to take out.
Install the fan. Connect the 3 wires. Fastened with 2 screws.
Put fan cover back on. 4 screws.
... Read more >Put back of freezer back on. 6 screws.
Put bottom of freezer back in. Slide gaskets in on each side.
Remove back of freezer. 6 screws.
Remove fan cover. 4 screws.
Remove fan. 3 wires to disconnect. 2 screws to take out.
Install the fan. Connect the 3 wires. Fastened with 2 screws.
Put fan cover back on. 4 screws.
... Read more >Put back of freezer back on. 6 screws.
Put bottom of freezer back in. Slide gaskets in on each side.
Read less
Was this helpful?
Thank you for voting!
Mounting bracket was riveted on old motor, mounting bracket holes on new motor were different
2 of 2 people
found this instruction helpful.
-
MIKE from ARLINGTON, OR
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
removed shims on screws holding motor together, enlarged hole in mounting bracket so motor screws could also go through mounting brackets.
Was this helpful?
Thank you for voting!
Replacing the bulb in the freezer side
5 of 11 people
found this instruction helpful.
-
Yafa (and David) from Bothell, WA
- Easy
- Less than 15 mins
-
Nutdriver
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this helpful?
Thank you for voting!
Gas smell
2 of 2 people
found this instruction helpful.
-
Garrett from PHILADELPHIA, PA
- Really Easy
- Less than 15 mins
-
Nutdriver
After removing the front panel, the igniter just just snaps into the bracket.
Was this helpful?
Thank you for voting!