Fridge stopped working
10 of 11 people found this instruction helpful.
  • Dan from Sumner, WA
  • Easy
  • 15 - 30 mins
  • Nutdriver
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used wha t he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
Was this helpful?
Thank you for voting!
Sides and door frames of the refrigerator warm to the touch.
10 of 12 people found this instruction helpful.
  • Dave from Bedford, IN
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
Confirmed the condenser fan was the problem when I noted it was not running when the compressor was on. Removed 3 mounting screws, unpluggede the fan. Removed and replaced the mounted flange(3 screws) and remounted. Plugged in fan and it started running.

Thanks for the diagrams and quick delivery. This is the second repai r on appliances I have made with your parts and probably saved $300-400 in service calls.
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
refrigerator and freezer not cold enough
8 of 8 people found this instruction helpful.
  • Greg from Williamstown, NJ
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Wrench (Adjustable)
I don't know anything about repairing a refrigerator - I'm a computer tech. I noticed that the outside of the fridge was warm to the touch and the inside was not getting as cold as it should. I took the lower back panel behind the fridge off and noticed that the fan was not spinning. The local parts dealers did not have the condenser fan motor that was needed but they did say that they do go bad. I decided to order one from PartSelect.com and do it myself. Using a 1/4 inch nut driver and a flat head screw driver to pry the old motor out of the casing, I got the job done in about an hour or so. It's a relativly easy job. Besides the ouside panel screws, there's 3 screws on the inside near the fan blades you have to reach in to get. Pop out the whole assembly, unscrew the nut that holds the blades on and pry out the old motor and replace.. Try it yourself and save a couple hundred bucks!
Was this helpful?
Thank you for voting!
Freezer and Refrigerator temperture unstable
8 of 10 people found this instruction helpful.
  • Alan from Brandon, VT
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set
My frig was cycling between upper 30's to 60 degrees, the freezer would make ice one day then be melting the next. I started by replacing the CONDENSER FAN MOTOR, relatively easy, unplug the motor, ratchet off the three supporting screws, splice the wires together, attach the ground wire and reinstall. That didn't seem to fix my problem.

I then ordered the Defrost Thermostat and Defrost Timer, based on past advice these were frequently replaced parts. Both installs were easy, the DEFROST TIMER was installed first, one screw holds the housing in the fridge, just unplug and unclip and install the new one. Very easy. This didn't seem to correct the problem overnight. I then installed the DEFROST THERMOSTAT, which was a couple of screws in the back of the freezer and uncip and install the new one. Very easy. This seemed to help the freezer maintain temperature, but the frig was still cycling up and down in temp on a daily basis and I had the temp knob all the way to 7 when it would normally work at 4.

I ordered the TEMPERATURE CONTROL ASSEMBLY. Easy to install, in the same housing as the Defrost timer, unhook some wires, reinstall and run the coiled part toward the back of the housing. This fixed the problem and has maintained my temp in the mid to lower 40's at the setting of 4.
Was this helpful?
Thank you for voting!
shelf bar end caps broke
7 of 7 people found this instruction helpful.
  • Donald from Taneytown, MD
  • Really Easy
  • Less than 15 mins
slid new end caps onto bar and snaped back in to door. It took less than 1 minute.
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people found this instruction helpful.
  • Michael from East Meadow, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
freezer was leeking in the fridge and floor.Freezer drain was cracked
7 of 8 people found this instruction helpful.
  • frederic from port st lucie, FL
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First I removed the screw that held the housing in place. I then pulled the housing out about 3 inches and disconnected the wires.Put old housing next to new one and started stripping old housing and building new one.Reconnected the wires and screwed in place 15 min max
Was this helpful?
Thank you for voting!
The evaporator fan quit working (second one to do so, even tho it is only about 5-6 years old), therefore frig would not stay cold
7 of 8 people found this instruction helpful.
  • Kathleen from New Port Richey, FL
  • Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
Thanks to someone else who had shared their repair story, we followed what she said she had done. Of course, we cut the power first, disconnected the ice maker, took the back off of the freezer compartment (from the inside), disconnected the defective fan motor. The fan blade just pulls off, you don't need a new one just because you need a new motor. Although the new motor came with a plug, there did not seem to be anyplace to plug it in. It was broken once before (5-6 year old name brand frig shouldn't have broken once, let alone twice....I anticipate more motors in my future, but at least I know how to fix it and where to get the part from), and the repairman had put the wires together and taped them up with electrical tape. My husband had no choice but to strip the wires and do the same, the wires are colored, so it is easy to connect them back again. It worked instantly. It works beautifully now. I have to add, in spite of the fact that I chose the most economical delivery choice, my part still arrived the very next day (a.m., at that!). I will say that I am very happy with PartSelect service and the information provided on their site which enabled me (my husband) to fix our refrigerator at a fraction of the cost of the last time it needed repair. Absolutely would refer to anyone, and use again myself (although, hope I don't need to!!)
Was this helpful?
Thank you for voting!
This is the second time this paticular motor has failed, refridgerator got warm, stuff in freezer thawed first.
6 of 6 people found this instruction helpful.
  • Jeffrey from Beaver Dam, WI
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
Checked the electrical circuits to find out if there was power to the fan motor. there was and the motor would not run. Further testing found the motor DOA. Pulled freezer compartment apart, removed the Ice maker, unscrewed the four screws that hold the evaporator cover on the back of the compartment, and removed mounting bracket for the evaporator fan / motor. there is a two wire molex connector that you pull apart, two wires on the compartment light and everything is free. Swap out the motor and reverse the procedure.
Was this helpful?
Thank you for voting!
broken shelf supports
7 of 9 people found this instruction helpful.
  • vickie from Acworth, GA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It was easy breezy!! I felt like an empowered woman that I did it myself. I simply removed the old shelf supports with a screwdrive and inserted a screw thru the new supports and screwed them in.
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people found this instruction helpful.
  • Antonio from San Antonio, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
freezing of evaporator and no cold airflow to fridge side from freezer.
6 of 8 people found this instruction helpful.
  • david from yucaipa, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Socket set
First i unplugged the appliance!!! Then I removed the three screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. installed fan.
Removed inside panels from back of freezer and de-frosted coils with hair dryer (20mins).
CAUTION! "Mop up and dry area of exsess water be fore pluging appliance back in!
Re- assemble panels and plug in.
Was this helpful?
Thank you for voting!
Old evaporator fan motor died
5 of 5 people found this instruction helpful.
  • Richard from DeKalb, IL
  • Easy
  • 1- 2 hours
  • Nutdriver, Screw drivers
Removed 2 screws holding left side of ice tray. Removed 4 screws holding back of freezer compartment in place.
Pulled center plastic air duct out of freezer.
loosened two screws holding fan mount on either side of central fan hole.
Pulled top of freezer compartment back down to expose fan and mount.
Removed fan moun t screws and unplugged fan.
disassembled fan mount and removed fan blace from motor.
reassembled mount and motor being sure rubber bushings are in place.
Put fan blace back on new motor (slip fit).
Remounted fan mount on freezer back and plugged in.
Reassembled in reverse order.
This time I kept the old motor (2nd one in 3 years) so I can identify the replacement easily by photo.
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people found this instruction helpful.
  • Duncan from Metairie, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!