Outer element of dual element burner didn't work
Remove Ceran Galss top by removing hex screws below the rim. Also remove the two opposing screws in the center of the downdraft opening. Ceran top comes off easily now.
The instructions with the new switch were very poorly written, so here is how I got the new switch to work:
Attach the black wire(s) from the old switch (terminal 2) to the new switch terminal P1. Also attach the jumper cable to P1 and "jump" it to S1.

Attach the orange wire (old switch terminal 5) to S2
Attach the yellow wire (old switch terminal 4) to 4a
Attach the tan/(white?) wire (old switch terminal 3) to terminal 4 on the new switch
Attach the single red wire from the right front element to terminal 2 on the new switch.
Attach the 'compound' red wires (the ones that come from the left rear/outlet connection and is also attached to the right rear switch) to terminal P2 on the new switch.
There is no need to seperate the compound red wires as the instructions might lead you to believe.
Good Luck
Parts Used:
Dual Surface Burner Switch Kit
  • Michael from Collierville, TN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
137 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The repair itself was very easy. “How to connect” was very hard to get.
The repair itself was very easy. “How to connect” was very hard to get.


To get access to the switch, unscrew 2 screws from each side of front panel and then 4 screws from the bottom of it (open the door first). Have a box or a small table about 30” high to use it as support for the front panel.

The end result (colors for the Right Front- R.F.- burner) : Old label -> New label

1. Double RED: N -> P2 (incoming power, Line 1)
2. Single RED: N -> 2 (to Inner AND Outer heating elements common wire)
3. Single BLK: L1 -> P1 (incoming power, Line 2)
4. Single TAN: H1 -> 4 (to the Inner heating element)
5. Single YEL: H2-> 4a (to the Inner heating element)
6. Single BLK: P -> S2 (to the R.F. indicator control light)
7. Attach jumper black wire (included with new switch) from P1 (P1 has two connectors close together) to S1.

Done.
Parts Used:
Dual Surface Burner Switch Kit
  • Igor from Campbell, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
51 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Jenn Air Dual element switch broke
This is not at hard as it seems; I followed the first guy's story and ignored the colors because mine were different. I did have to split the combined red wires, intimidating at first but once I split them it was down hill.
I did have to use the jumper wire.

Follow
Appliance Repaired: Jenn-Air Range/Stove/Oven/Hood

Model: cve3401b

Age Of Appliance: 5 - 10 years


Remove Ceran Galss top by removing hex screws below the rim. Also remove the two opposing screws in the center of the downdraft opening. Ceran top comes off easily now.
The instructions with the new switch were very poorly written, so here is how I got the new switch to work:
Attach the black wire(s) from the old switch (terminal 2) to the new switch terminal P1. Also attach the jumper cable to P1 and "jump" it to S1.

Attach the wire from old switch terminal 5)to S2
Attach the wire from old switch terminal 4 to 4a
Attach the wire from old switch terminal 3 to terminal 4 on the new switch
Detach the 'compound' red wires from each other.
(The ones that come from the left rear/outlet connection and is also attached to the right rear switch) to terminal P2 on the new switch.

I attached common female connectors.
Attach the newly split single red wire from the right front element to terminal 2 on the new switch.

One note:

Before you remove the four screws that hold the four swtiches down make sure that you use a sharpie and mark the switchbox location. You will notice that it is difficult to get them to line up again with the holes in the cooktop.

Thanks partselect.com!
Parts Used:
Dual Surface Burner Switch Kit
  • Todd from Concord, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dual Infinite Switch shorted out due to boil over on the cooktop.
I turned off the circuit breaker to the cooktop. I had to remove aluminum tape from the downdraft fan so it would disconnect from the exhaust duct. I noticed that I had a long enough electrical connection so I could just lift the cooktop up out of the opening and support it at the corners with shims. I removed all the knobs from the cooktop and then removed the 1/4" sheet metal screws that held the ceramic top to the base. My cooktop had a downdraft fan in the center which has 2 phillips head screws that at first I didn't see, but once I removed those, the ceramic top came off and exposed all the inner workings. I removed the 2 phillips screws holding the switch and then swapped each wire from the old switch to the new one. After that, it was just a matter of reversing the process to get everything back in working order.
Parts Used:
Dual Surface Burner Switch Kit
  • Ronald from Beavercreek, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
burner/s could only be on off or high, nothing in between
First, disconnected downdraft fan from ductwork below stovetop. Pushing from below, was able to lift entire stovetop assembly up to expose nuts holding glass top to the underlying burner assembly. used 2 lengths of 2x4's under the whole stovetop assembly to hold it up while I worked. Unscrewed all hex nuts and 2 screws at top of downdraft opening and easily lifted glass top off, exposing elements below. Removed a few screws holding defective switch in place. I then moved one wire at a time from the old switch to the new switch. I actually followed directions of another partsect customer. His step by step directions for the wiring was invaluable. Worked perfectly. My wife and daughter are very impressed.
Parts Used:
Dual Surface Burner Switch Kit
  • Michael from West Hartford, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Small burner full hot all the time.
TURNED OFF POWER TO STOVE Removed 5 Knobs, 2 screws that held bad switch.
Removed 4 screws and lifted panel up and forward to expose switches. Adjusted spring tension on knob stem to hold knob ( stem in new switch slightly smaller) removed wire from defective switch one at a time and fastened to new switch in sequence. Reassembled and turned power on. Defective switch had stuck contacts making it full hot.
Parts Used:
Surface Infinite Switch
  • RICHARD from PARADISE, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
16 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Small burner would not work and could not control heat when large burner was on
I had an electrician do it. The instructions were horrible. He followed the instructions from your web site. The cooktop was not on an island so he could not remove all the screws to release the top so he worked with the top propped up. When he finally got the connections on, the small burner would not work only the large outer burner is working. He went on the computer to see if he could get more information but was unable to find any information.
Parts Used:
Dual Surface Burner Switch Kit
  • Beverly from Manteca, CA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench set
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Jenn-Air dual burner would not turn off
Followed the first persons instructions and they worked perfectly including using the jumper wire.
Parts Used:
Dual Surface Burner Switch Kit
  • James from CENTENNIAL, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The burner would turn on and not off. The temperature just kept accelerating.
Raised the unit and blocked it with 2 boards. TURN OFF THE POWER IF YOU WANT TO COMPLETE THIS REPAIR. Removed the philip head screws for removal of glass top. Remove the corner screws on switch end. Remove screws holding the switch. Remove screws holing the bracket for all switches. Lift and roll gently to get at wiring. Follow the directions for moving wires from old switch to new switch. MOVING WIRES IS THE MOST IMPORTANT STEP. Reverse your procedure to put back together and when finished remember to turn on the power.
Parts Used:
Dual Surface Burner Switch Kit
  • Norbert from SPARTANBURG, SC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Engaging dual burner switch would blow breaker. All other elements worked fine.
Isolated circuit by disconnecting cooktop breaker.
Disconnected blower duct, raised cooktop above the countertop to access screws holding the glass surface.
Blocked in place--no need to completely remove cooktop.
Removed screws around top of pan with 1/4-inch nut driver--only need to remove any screws close to top of pan and glass surface.
Lifted off glass surface.
Dual burner switch bracket needs to be removed to access switch and to disconnect wire harness connections.
Note there was one screw holding bottom of bracket which was hidden by the wire harness.
I was concerned with connections from other reviews; however, in my case, the switch and connections were identical to the original--no problem.
Reinstalled bracket and glass cooktop--need to remember flange location (inside versus outside) to assure easy alignment of screws. Drop cooktop back into countertop and reconnect blower duct.
Powered back up and dual burner now fully functional.
Parts Used:
Dual Surface Burner Switch Kit
  • Charled from MINNEAPOLIS, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replaced a broken dual burner switch
IMPORTANT WIRE CONNECTIONS: The manufacturer instructions describing where each wire connects is woefully incomplete. There are 6 or 7 wires to connect and only 2 are explained in the instructions. I took several photos of the original switch showing where each of the wires was connected before disconnecting and installing the new switch. If I hadn't taken the photos I would have been completely lost on where each wire connected.
Parts Used:
Dual Surface Burner Switch Kit
  • chris from ann arbor, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
indicator ring worked intermittently, no heat
raising the cook top on to 2x2s, one on each end, allowed me to remove the 9 sheet metal screws that keep the glass top fastened to the box containing all of the heating elements and controls. After removing the control knobs and the glass top, everything was clearly visible. Removing the four screws that hold the control box frame in place allowed me to turn the switches upside down and photograph the placement of all of the wires on the pins. I then transferred the wires from the old switch to what I thought were the corresponding pins on the new switch(the replacement switch has more pins, and they are not located in exactly the same spots as the old switch). When I turned the power back on, the switch turned the burners on, I had heat but the indicator lights didn't work. I turned the breakers back off and rewired according to a previous commentors wiring directions(his model was not exactly the same as mine), the indicators worked but I was back to no heat. I called my son, who has his own commercial electric company,and he looked at my photos from before, the diagram that came with the new switch, and it took him about 15 minutes to reconnect the pins to different wires and when we turned the power back on---both indicators and heating elements worked. It was the dual switch and double indicator that made it more complex to figure out. Nice to have very smart kids.
Parts Used:
Dual Surface Burner Switch Kit
  • Alan from Louisville, NE
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The instructions were confusing concerning the attachment of the red wires
Trial and error and reading and rereading the instructions.The use of the jumper wire was not detailed enough. Caller a repair man.
Parts Used:
Dual Surface Burner Switch Kit
  • Otto from Goldsboro, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burner switch was shorting circuit breaker
Removed glass top from stove by taking out hex screws which secured glass top to stove frame. There are two phillips head screws inside the exhaust as well. Removed two phillips head screws which hold the burner switch in place. With a sharpie pen I marked the color coded wires on the faulty switch. Removed wires from the faulty switch. Replaced new switch using the old switch as a guide to insure that wires were connected properly. Secured new switch and glass burner top reversing above procedure. Problem solved. Note: The white dot on the control knob did not line up properly with the off position. Black out white dot and make a new one in the proper spot on the knob.
Parts Used:
Dual Surface Burner Switch Kit
  • Robert from Jacksonville, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
faulty dual surface burner swich
I followed your excellent service instructions.
This was the reason I purchased the part from you,
even though other websites had the same part for considerably less
Parts Used:
Dual Surface Burner Switch Kit
  • olof from san diego, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!