Stopped cooling
Removed panel from inside the back of the freezer section, by removing four screws. Then, sprayed the ice build-up on the coils, with hot water until all of the ice was melted away. (Note: be certain to plug the drain hole, and use several towels to catch the water drainage. ) Removed the Defrost Heater Element by removing two holding screws. Unplug the unit and pluged-in the new unit and replaced all screws as originally mounted.
Parts Used:
Defrost Heater Harness Kit
  • Curt from Selma, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser wouldn't work and refrigerator made an almost ghost like howling sound. Replacement main board fixed the noise. I purchased the replacement board for the ice and water (front of the refer) but haven't installed it yet.
I watched the on live video. Piece of cake!
Parts Used:
Main Electronic Control Board
  • Brian from Woodland, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water in door dispensor quit working
First, I turned off the water supply line to the refrigerator from the house at the wall and unplugged the power cord. Secondly, I removed the small screws that hold the piece of cardboard over the opening in the lower left corner (rear of the refrigerator) by the compressor. Thirdlyl, I removed the other end of the water line where it attaches to the water valve with an adjustable end wrench. Then I removed the small screw that holds the double water outlet valves to the refrigerator frame. I then removed the water valve by pulling it out of the rear of the refrigerator, unplugged the electrical connections, and cut the water lines where they enter the valves. I then plugged the electrical connectors into the new valves and pushed the hoses into their respective openings. These are one-way connectors - once you push them in (firmly) they will not leak or come back out. All I did then was replace the valve and secure it with the one little screw and then replace the cardboard piece onto the rear of the refrigerator. Don't forget to turn the water supply back on. That's it!!
Parts Used:
WATER VALVE WITH GUARD
  • Richard from Temecula, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator and freezer would not cool down.
First, we called Sears Repair and had a technician come to our home. He stated the motherboard had gone bad probably due to a power surge (we had no surge protector on the appliance). His price for repair was $465.00. We opted to go online for the part and found it for $165.00 through PartSelect.com. It was a very simple procedure of removing the old and installing the new. A few turns with the nut driver to uncover the part, a few tugs with the pliers to disconnect and voila!.. The fridge was back to cooling in no time.
Parts Used:
Main Electronic Control Board
  • John from Lakeland, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Low water flow from indoor water dispenser
Disconnect main water line from behind refrigerator
Remove bottom panel from refrigerator
Disconnect hose from water valve
Remove metal hose guard from top left of refrigerator Carefully remove plumbers putty from around filter hose (you will be reinstalling this putty around new hose assembly)
Inside refrigerator remove MWF water filter and guard, and then remove two screws holding filter assembly in place (this requires socket set with 4” extension bar)
Carefully pull filter hose assembly towards you from front of refrigerator. Once assembly is out remove Styrofoam cover from old assembly and install on new assembly
To reassemble, simply follow this process in reverse. Good luck
Parts Used:
MWF MANIFOLD
  • Ricky from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
GE Profile Arctica food locker was below freezing
The trouble shooting information on the web site indicated that the damper door within the climate control unit may be broken. This was easily confirmed and the replacement of the climate control unit immediately returned the food locker temperatures to the digital electronic thermostat settings. The part has an improved ventilation gasket interface between the food locker and freezer. The unit works perfectly again, and the food locker temperature is exactly what the thermostat setting is.
Parts Used:
Air Inlet Cover Kit
  • Frederick K from Kingston, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old tray had split hands.
Slip out old one, slide in new tray!
Parts Used:
PAN SNACK ASM
  • Mark from LAKE WORTH, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils in Freezer over frosted restricting air flow.Warm Frig.
1) Unplug Refrigerator. Remove all shelves and light shield in the freezer.
2)Remove panel covering refrigeration coils inside freezer in back. Two hex head screws w/nut driver.
3)Remove the defrost heater using phillips screw driver. Two screws.
4)Unplug two quick disconnect stakons and wires from heater.
5)Plug the wire coming down the right side into one side of the new heater and plug the shipped white wire into the other quick disconnect spade at the heater.
6)Install the new dual element defrost heater into the same place where the old was. Connections to the right.
7)Route the wire that was on the left across the top of the coils and down the right side.
8)Bring the existing wire from the left side down the right side and the white wire up the right side. Wires should not be tight at all and do not remove the tape at the stakon.
9)Now wires need to be cut (if necessary)and crimped together in the shipped stakon. This stakon looks like a wire nut.
10)Wires should be tucked gently into the styrofoam up and down the right side. Wirenut should be positioned so that water can not collect in it.
11)Replace the panel over the cooling coils.
12)Plug Refigerator back into the wall outlet. Put shelves and light shield back in.
13)My refrigerator is now working without a problem. It's been est two weeks.
Ice maker is also working correctly.
Parts Used:
Defrost Heater Harness Kit
  • Timothy from Hartford, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak on floor
pulled out refer. found leak at corner lower back, pulled off lower cover. found valve for icemaker leaking. looked in owners/inst guide, pulled up on computer, identified part, called, order overnight part. recieved part & installed, repair complete & successful.
Parts Used:
WATER VALVE WITH GUARD
  • Gerald from Colorado Springs, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set, Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water dispenser was slowly leaking
Shut off water supply. Unplugged refrigerator. Removed cover. (6 screws -- nutdriver will come in handy). Removed screw securing water valve to frame (again the nutdriver). Unplugged red and white power connectors to solenoids. Using channel locks, loosened nut holding main water supply to valve and removed. Depressed compression fittings to valve and pulled out plastic water lines that supply water dispenser and ice maker. Reconnected main water supply to new part. Pushed both water lines into respective fittings of new part. Reconnected power supply to solenoids. Attached new part to frame with screw. Replaced back cover. Turned water supply back on. Plugged refrig. back in. Problem solved! Savings = $300!
Parts Used:
WATER VALVE WITH GUARD
  • Robert from Huber Heights, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dispensed water but not cubes/crushed ice.
removed 3 screws with 1/4 " nut driver, unplugged 2 plugs by prying out on side tabs, removed bracket and motor. Used vice grips to hold motor shaft and used screwdriver to turn auger fork clockwise and remove. Unplugged two connectors from motor. removed 3 screws with 1/4" nut driver to remove motor. changed rubber boot from old motor to new. Reversed procedures to install new motor on bracket, auger fork, bracket in freezer, etc. Only difficulty getting both hands in narrow freezer compartment. Still didn't work, called repairman. When he got here I showed him the problem and lo and behold, now it would not dispense water. He diagnosed it as a bad motherboard, replaced it and all good now. Motherboard $150, diagnose and labor $90, but it is all good now and I even have a spare motor. The failing mother board causes strange howling noises at times and we discovered the compressor fan had also stopped working and in a short while I would have had a bad problem. Caught it just in time!!!
Parts Used:
Auger Motor
  • Tim from Klamath Falls, OR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water from the dispenser
I pulled-out & unplugged the refrigerator. Removed the screws to gain access through the lower back panel. The water valve is on the left side as I face the back of the fridge. It has one screw holding it to the frame of the fridge. Once it is free, the main water hose is unscrewed and the two out-let lines were pulled-out. If your valve was not ruined prior to this, it is ruined now, as the lines will not re-seat. Then everything is done in reverse order. I did cut 1/2 inch off of the two lines so that they reseat into the new valve. Just push into the valve and they are good.
Parts Used:
WATER VALVE WITH GUARD
  • Anthony from Carmel, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
union connector leaking
replaced with new connector and it worked great. also replaced the water filter and that was super easy!
Parts Used:
Refrigerator Ice and Water Filter Union Connector - 5/16 Inch to 5/16 Inch
  • Amy from Bryan, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water will not dispense and the refrigerator drawers were freezing our foods and vegetables.
It was a simple remove and replace. The new part fits directly in place of the old part. Its a pain to remove the light but once you get the light out the job is simple. The light must be pried out gently. It is snapped in place toward the air inlet cover and needs to be pried loose. Once the light is out there are 4 screws holding the air inlet cover in place. Remove the 4 screws and unfasten the wiring harness. Once the screws and wiring harness are disconnected remove the old part. Reinstall the new part in reverse order.
Parts Used:
Air Inlet Cover Kit
  • Jeff from Manteca, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
Parts Used:
WATER VALVE WITH GUARD
  • Jake from Brainerd, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Wrench (Adjustable)
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 39631UGTAWW