36358047897 Kenmore Refrigerator - Instructions

All Instructions for the 36358047897
76 - 90 of 748

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Freezer hinge was worn
6 of 6 people found this instruction helpful.
  • Wilbur from Waynesboro, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Wrench (Adjustable)
Shut off water and disconnected at factory joint at bottom hinge. Unplugged the electrical at the top hinge. Removed the door and installed new bottom hinge and cam assembly. Reinstalled the door and hooked water and electric back up. Part worked fine.
Was this helpful?
Thank you for voting!
Refrigerator would not defrost
7 of 10 people found this instruction helpful.
  • Thomas from Dresden, OH
  • Really Easy
  • Less than 15 mins
  • Nutdriver
When it was discovered there was a cooling problem in the refrigerator, I went to parts select web site and went through the troubleshooting section. Then I tested the defrost timer and the defrost element as directed by the web site. I then found out doing this, that is was the defrost timer. I ordered the part online and it was delivere d THE NEXT DAY! I removed the bottom panel of the fridge, removed the screw holding the old timer, removed the wires, and reversed the procedure to install the new one. It has been 1 week, and everything is working great. Thank you PartSelect.
I have since then recommended you to a relative who was having the same problem. Thanks again.
Was this helpful?
Thank you for voting!
Coils in Freezer over frosted restricting air flow.Warm Frig.
7 of 10 people found this instruction helpful.
  • Timothy from Hartford, MI
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
1) Unplug Refrigerator. Remove all shelves and light shield in the freezer.
2)Remove panel covering refrigeration coils inside freezer in back. Two hex head screws w/nut driver.
3)Remove the defrost heater using phillips screw driver. Two screws.
4)Unplug two quick disconnect stakons and wires from heater.
5)Plug the w ire coming down the right side into one side of the new heater and plug the shipped white wire into the other quick disconnect spade at the heater.
6)Install the new dual element defrost heater into the same place where the old was. Connections to the right.
7)Route the wire that was on the left across the top of the coils and down the right side.
8)Bring the existing wire from the left side down the right side and the white wire up the right side. Wires should not be tight at all and do not remove the tape at the stakon.
9)Now wires need to be cut (if necessary)and crimped together in the shipped stakon. This stakon looks like a wire nut.
10)Wires should be tucked gently into the styrofoam up and down the right side. Wirenut should be positioned so that water can not collect in it.
11)Replace the panel over the cooling coils.
12)Plug Refigerator back into the wall outlet. Put shelves and light shield back in.
13)My refrigerator is now working without a problem. It's been est two weeks.
Ice maker is also working correctly.
Was this helpful?
Thank you for voting!
light not working
7 of 11 people found this instruction helpful.
  • robert from FRANKLIN SQ, NY
  • Very Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Was this helpful?
Thank you for voting!
Refrigerator door would not shut
5 of 5 people found this instruction helpful.
  • Bobby from SENECA, SC
  • Very Easy
  • 15 - 30 mins
  • Socket set
Removed old hinge assembly, bolted on new assembly-door shut like new
Was this helpful?
Thank you for voting!
Refrigerator to warm
5 of 5 people found this instruction helpful.
  • Lloyd from PITTSBURG, CA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
Was this helpful?
Thank you for voting!
Unit had stopped making ice
5 of 5 people found this instruction helpful.
  • Ron from ORANGE, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Was this helpful?
Thank you for voting!
broken auger in the bucket assembly.
6 of 9 people found this instruction helpful.
  • Chip from Mandeville, LA
  • Easy
  • Less than 15 mins
  • Nutdriver
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this helpful?
Thank you for voting!
Ice bucket cracked
6 of 9 people found this instruction helpful.
  • Betty from Downers Grove, IL
  • Really Easy
  • Less than 15 mins
We have an older model refrigerator and thought it would be impossible to find a replacement ice bucket for the freezer. Not only did you have the exact part but it came unbelieveably fast. I would use your website again!
Was this helpful?
Thank you for voting!
door wouldn't close
5 of 6 people found this instruction helpful.
  • Linda from Manorville, NY
  • Easy
  • 15 - 30 mins
  • Socket set
First I propped up the door. Then I removed the 2 screws that hold the hinge on. AT this point you do need someone else because the door swings loose. I attached the new bracket and lowered the door. It went verey smooth. I ordered the new bracket after reading the installation stories from others who just repaced the plastic pieces. Its worth the extra money to just put on a new bracket
Was this helpful?
Thank you for voting!
no Ice
5 of 6 people found this instruction helpful.
  • George from Brandywine, MD
  • Easy
  • 15 - 30 mins
  • Nutdriver
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker fi lled with water and a short time later I had ice. Easy job.
Was this helpful?
Thank you for voting!
Ice Maker would not fill.
5 of 6 people found this instruction helpful.
  • Charles from Keller, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this helpful?
Thank you for voting!
Freezer stayed cold but Fridge got warm every 3 weeks
5 of 6 people found this instruction helpful.
  • Mike from Seaford, NY
  • Easy
  • 30 - 60 mins
  • Screw drivers
Unplug the fridge, then:
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and p lace a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed

I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.

Thank You PartSelect!
Was this helpful?
Thank you for voting!
The Icemaker failed to make ice
8 of 16 people found this instruction helpful.
  • Dean from Folsom, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement i cemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this helpful?
Thank you for voting!
Hinge Cam Riser broke - door wouldn't self-close
4 of 4 people found this instruction helpful.
  • Richard from Los Altos, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
I removed all of the items in the refrigerator door. I then removed the top hinge cover with a Philips screwdriver, and removed the two machine screws holding the top hinge using a socket wrench. This allowed me to lift the door off the bottom hinge pins and set the door on its side. I removed the two screws holding on the broken botto m hinge cam riser block and replace it with the new one. After tighening it back with a socket wrench, I tried to put the door back in place. I asked my wife to hold the door steady while I lay on the floor to guide the door downward over the bottom hinge pin. I then replaced the top hinge screws and checked the door. It still didn't close on its own! I realized I had to loosen the top hinge screws and adjust the door so that it stands more vertically (evening the gap with the freezer door). With this adjustment, the door closes fine.
Was this helpful?
Thank you for voting!
All Instructions for the 36358047897