Quit making ice.
37 of 49 people found this instruction helpful.
  • Joe from Brentwood, TN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
Was this helpful?
Thank you for voting!
ice maker leaked water slowly and froze the cubes together
41 of 62 people found this instruction helpful.
  • Steven from Cave Creek, AZ
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Was this helpful?
Thank you for voting!
Panel hot to touch between freezer & refrigerator. Motor hot, fan not rotating.
32 of 39 people found this instruction helpful.
  • Kimberly from Grandy, NC
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Unplugged refrigerator, removed three screws to take out part, disconnected the wires and removed bad unit. Removed fan blade from old unit and attached to the new unit. Attached wires, placed the new motor back in. Plugged it back in, within 20 minutes panel between freezer and refrigerator was cool to touch.
Was this helpful?
Thank you for voting!
Ice was melting and freezing in bucket
33 of 42 people found this instruction helpful.
  • John from Lodi, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Was this helpful?
Thank you for voting!
Light switch inside refrigerator wasn't working
31 of 43 people found this instruction helpful.
  • Erick from Elmhurst, NY
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
First turned off power and removed top shelf.
Then I used a flathead to slowly pry the switch out by the two sides. You just anlge ita bit and it slideds out easily. Then I disconnected the wires from the old switch, connected the new one and installed the new switch by snapping it back into the cutout.
Was this helpful?
Thank you for voting!
defrost heater burned out - coils froze over
27 of 32 people found this instruction helpful.
  • Robin from Vernon Hills, IL
  • Easy
  • 15 - 30 mins
  • Screw drivers
Troubleshooting was easy - others had the same problem - coils freeze over and frost blocks air flow to refrigerator - part identification made easier by online picture - many parts look the same so you may want to call and confirm before you order (there were variations to this model number) - To repair: take off five screws that hold t he metal panel on the back of the freezer - remove the panel - use a heat gun or hair dryer to melt ice from the coils (put a towel at the bottom to soak up the water) - unplug the kit at the top of the freezer and carefully pull off the thermostat clipped to the coil - remove the four screws that hold the heater kit to the back of the freezer - install the new kit where the old one was then re-install the panel to the back of the freezer - next, make time to clean the condenser coils under the refrigerator/freezer
Was this helpful?
Thank you for voting!
Frezzer section froze over with ice.
27 of 32 people found this instruction helpful.
  • JOSEPH from ORELAND, PA
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
Couldn't find schematic or repair manual
Finally found your site which showed the location and part numbers of the timer and heaters.
I ordered them; they came immediately.
I replaced only the timer, since it was the easiest and took only a few minutes. Defrosting the frezer coils with a hair dryer took about an hour. ... Read more >Rerigerator froze over again in about two weeks.
I then replaced the heaters. One of the heaters was 'open circuit'.
Was this helpful?
Thank you for voting!
Door gasket was broken at the bottom
23 of 25 people found this instruction helpful.
  • Sonny from Bennettsville, SC
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
First, I made a mistake. I took all the screws out and removed the gasket. This allowed the door tray to drop loose. Then, I realized that wasn't the way to go. So I remounted the door tray and the metal gasket supports but left the screws loose. Then, starting at the top, I worked the new gasket in behind the metal supports and tigh tened the screws along the way. I completed the installation by following this same method down the sides and at the bottom.
Was this helpful?
Thank you for voting!
Failed Icemaker
35 of 62 people found this instruction helpful.
  • GARY from PARRISH, FL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Wrench set
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Was this helpful?
Thank you for voting!
Fridge door wouldn't close easily like it used to
21 of 22 people found this instruction helpful.
  • Christopher from Roseville, MN
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Socket set
This is a sibe-by-side refrigerator/freezer that needed a new lower hinge set for the fridge door.

First I removed everything from inside the fridge door, closed it, then loosened the top hinge bolts with an 8mm socket on a 1/4-inch ratchet. Using an 8mm nutdriver, I removed one bolt and loosed the other just far enough to be able to lift the hinge and swing it out of the way. (These bolts are long. The nutdriver is faster than the ratchet but you need a ratchet or a wrench to first break them loose.) Then I just lifted the door off the bottom hinge and set it aside.

The plastic lower front grill was covering the lower hinge but that grill is just held at the ends by spring clamps -- popped off easily so I could get to the hinge bolts. Again, 8mm bolts, just remove & replace hinge. I also had to replace the upper half of the door closer cam, which is screwed to the bottom of the door, being careful that the holes lined up: cam, shim, door holes.

Now the tricky part was lifitng the door back on the lower hinge. (It helps to have an assistant at the bottom to locate the hole for you.) Once the door was up, I swung the top hinge over, ran the two bolts in finger tight with my nutdriver, checked & adjusted the spacing* of the fridge door and tightened the bolts. This was all very easy! (*^_^*)

*On a side-by-side, you'll want the door to be straight up & down with a consistent gap top to bottom with the freezer door. The hinge has some slack for adjustment by positioning the door, then tightening the bolts. You'll see what I mean.
Was this helpful?
Thank you for voting!
ref/freezer would not maintain proper temp. Ran all the time or would not come on once it quit running. Freezer would get too warm or ref. would get too cold and freeze contents.
23 of 28 people found this instruction helpful.
  • Ronald from Southlake, TX
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
1. Unplug, remove control knob from both temp control sliders, remove upper light bulb and light shield from refrigerator compartment. 2. Remove screw holding top of bracket control mod in place. 3. Lift bottom tab from slot and remove control mod from ref compartment. 3. Unplug temperature control and defrost timer and replace. (Each are held in place with two screws.) 4. Replace control mod. This part took me the longest because the space between the top of the control mod and the top of the ref. compartment is very small and replacing the nut was difficult. Use a nut driver with a long shaft. 5. Use screw driver to turn control button of defrost timer to start cycle. 6. Replace bulb cover and light bulb. 7. Set temp control to initial setting. 8. Have a Margarita and celebrate. It's been over a week and the refrigerator/freezer is working perfectly.
Was this helpful?
Thank you for voting!
low flowing water (not just a drip) from refrigerator ice maker
23 of 30 people found this instruction helpful.
  • Theresa from Rochester, MI
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers, Wrench (Adjustable)
The icemaker's valve is easy to inspect and test. First, gently pull the refrigerator away from the wall, and unplug it. Turn off the water supply to the icemaker by closing the shut-off valve in the copper waterline leading to the valve. Use a screwdriver or nutdriver to remove the rear lower access panel from the refrigerator's back.