Intermittent loud noise coming from fan motor located in freezer compartment
Ordered a new evaporator fan motor and watched the repair video supplied by part select on their web site.It was spot on step by step instructions
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Donald from Okeechobee, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light not turning on when door opened
Used a flat head screwdriver to pop out the old switch, removed the contacts and placed on the new switch, popped the switch back in. Done in about 2 minutes.
Parts Used:
Light Switch
  • Michael from TUCSON, AZ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy condenser fan
Remove lower cardboard refrigerator panel. Carefully pull existing cracked fan blade off of the motor shaft and replace with new fan blade. Reinstall cardboard panel.
Parts Used:
Fan Blade
  • Ben from FRANKLIN, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator evaporator coil was icing up
The evaporator coil is behind the freezer. Remove the rack that makes the shelf and remove two 1/4” hex head screws I the back of the freezer to access the coil.
I used a hair dryer to melt the ice off the coil.
The thermostat clips on the refrigeration pipe to the coil. Remove the old thermostat and cut the wires at least a few inches from the thermostat. Clip the new thermostat on the pipe and strip about a 1/4” of the wire ends. The electrical connectors (provided with the new part) must be crimped to connect the wires.
Parts Used:
Defrost Thermostat
  • David from VENICE, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator wasn't getting cold the freezer was getting to cold
Followed the installation instruction for both parts now both the freezer and refrigerator are getting cold
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • eddie from CHICAGO, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge and freezer both freezing at bottom and warm at top.
Unplugged fridge. Removed freezer shelves and unscrewed and removed plastic shelf brackets. Removed the lower rear panel. Removed the bin for ice. Removed the 2 exposed upper rear panel screws. At this point I was able to flex the panel quite enough to access the fan motor. Carefully plugged the fridge back in and turned it on long enough to verify the existing evap. fan motor was not running. Powered off and unplugged again. Removed the fan and it's support assembly, and replaced with new. Had to cut the wires and splice and crimp with the provided wire nuts since the plugs in this model were different. Powered on fridge to check fan function. Reassemble and go home looking' like a hero! Saved my BFF a couple hundred bucks.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Stephen from PERRIS, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bilb went out
replaced it
Parts Used:
Light Bulb
  • Denise from Landover, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No freezing or cold in either freezer or refridgerator - compressor did not run.
Traced issue to defrost timer ( burned compressor & element contacts). This unit is mounted next to the temperature adjustment control in the refridgerator area - right in front. Removal of plastic cover provided easy access to the timer. Unit unscrews from the mounting then unplugs. Installation is reverse of removal.
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Sunnyvale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster didn't work
Ordered a new defroster timer and replace old one. It works just fine. A $35 repair vs a $500 new appliance.
Cool.
GWE
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Eatonville, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refer iced up and would not keep the bottom cool. It was 70 Farenheit inside.
I simply removed 4 screws holding the casing and then 2 more holding the timer. It was very easy. I then replaced the timer by unplugging and plugged the new one in. I replaced all the screws and the job was done. Less than 30 minutes. I was very impressed with the shipping time. When I ordered the part, I had it the next day.
Parts Used:
Defrost Timer - 60Hz 120V
  • Larry from Newton, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch prevented door from closing.
The switch prevented the door from closing about 5 years ago. So I just taped the switch down, and lived without a fridge light for the last 5 years. Painful! And wasteful (food spoiled because we couldn't see it.) Thought I was out of luck, assuming light switches were all the same, got fed up again, and pulled out old switch,,and searched the net for the part number, and just started calling the manufacturer. I got this website after no luck in calling, and took the step to order...and in no time, got it replaced, and we cam see now! It feels like we got a new fridge!
Parts Used:
Light Switch
  • Patrick from Penryn, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer built ice, fridge not cold enough and running constantly.
Removed front low grill, removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wires. Reversed process to install new timer.
Parts Used:
Defrost Timer - 60Hz 120V
  • LUIS from CENTENNIAL, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
coil Iceing up
took 4 screws out of the discharge vent on top of the refrigerator section and unpluged the wiring harness and put the section on the counter and unscrewed the timer and put the new one in and reinstalled the assembly and plugged the Jack and put the 4 screws back in, and rotated the timer and put it on defrost removed the back and check the heaters and drain .
Parts Used:
Defrost Timer - 60Hz 120V
  • Thomas from Stuart, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frezzer iceing over and not cooling the refrigerator
Just removed the two screws and unpluged it.
Then I pluged the new one in and replaced the screws. It runs like a brand new reffrigerator.
Thanks for the fast delevery. Will do busness with you in the future.
Parts Used:
Defrost Timer - 60Hz 120V
  • Marcus from Pine Hill, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the refrigerator door was hard to close, and upon inspection I finally decided that the light switch was making the door hard to close.
I removed the door actuated light switch with my index finger and thumb on my right hand. I then removed the two wires from the switch. I noticed that the new switch had different look to it,I think Frigidaire must have had a problem with the original design of the switch. Reassembly was just replacing the two wires and putting the new switch in place, and no more door closing problem.
Parts Used:
Light Switch
  • Paul from Springfield, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!