Compressor was short cycling
12 of 17 people
found this instruction helpful.
-
Sherman from Tuttle, OK
- Easy
- 30 - 60 mins
-
Screw drivers
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work"
... Read more
since that would be the most common reason and it was not a very expensive part.
Read less
Was this helpful?
Thank you for voting!
The fridge motor was running constantly and the fridge was warm inside
9 of 10 people
found this instruction helpful.
-
James from Brighton, TN
- Really Easy
- 30 - 60 mins
-
Screw drivers
I secured the power to the fridge. I took the metal panel which covers the cooling coils in the freezer off by removing the the 6 sheet metal screws. I used a standard hair dryer to melt the ice block which had formed due to the failure of the defrost timer. I replace the defrost timer, which was located behind the left front wheel of
... Read more
the unit. Finding the timer was the hardest part of the job. Since I was having trouble with the defrost cycle I also decided to replace the defrost thermostat due to its age. The most important item I would like to share is once all the work is done and the panel is back in the freezer, the power is restored take a straight slot screw driver and give the defrost timer about an eighth of a turn clockwise to ensure it starts. Then mark it with a sharpe and check it in 3 or 4 hours to make sure it is running. I did not do this on the one I installed and the freezer did not go into the defrost cycle. Once I got the timer started, well the ice cream stay frozen. BE SURE NOT TO WORK ON YOUR EQUIPMENT WITH IT PLUGGED INTO POWER SOURCE!!!
Jim
Jim
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
9 of 10 people
found this instruction helpful.
-
alonso from Compton, CA
- Easy
- 15 - 30 mins
-
Wrench (Adjustable)
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and t
... Read more
hen attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
Read less
Was this helpful?
Thank you for voting!
Erratic light.
9 of 11 people
found this instruction helpful.
-
D KIRKE from CORVALLIS, OR
- Really Easy
- Less than 15 mins
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement s
... Read more
witch.
Read less
Was this helpful?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
8 of 10 people
found this instruction helpful.
-
Melvin from OPELIKA, AL
- Very Easy
- Less than 15 mins
-
Screw drivers
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Was this helpful?
Thank you for voting!
freezer and refrigerator too warm
9 of 13 people
found this instruction helpful.
-
Joel from Sunny Isles Beach, FL
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
I put the refrigerator and saw that the fan wasn't working so I change the fan and the problem still the same. I order a timer and thermostat and change them, nothing change so I order the capacitor and when I remove it I saw that the relay swith was burn out so I order a switch and evarything is ok.
The problem when the fan broke th ... Read more e compressor overheat and burn the swich.
I learn a lot and still saving money over these repair guy.
Thanks
The problem when the fan broke th ... Read more e compressor overheat and burn the swich.
I learn a lot and still saving money over these repair guy.
Thanks
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
the evaporator fan stopped working
8 of 11 people
found this instruction helpful.
-
Stephen from Bloomfield, NJ
- Easy
- 15 - 30 mins
-
Screw drivers
I removed the plastic cowl in the rear of the freezer to gain access to the fan, took out two screws that secured the brackets holding the fan. Then I separated the coupling wires which had a sort of locking mechanism that was simple to undue. I took out the brackets along with the fan, separated the brackets and removed the screw for the
... Read more
ground wire. Then I simply reversed the process.
Read less
Was this helpful?
Thank you for voting!
Thought the evaporator fan was the issue
7 of 8 people
found this instruction helpful.
-
Dale from Fort Myers, FL
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver
Did the obvious. Removed the stick-out cover, then the back of the freezer wall, after taking the bad evaporator fan out. Replaced the old motor with the new one, stuck the fan blades back on, and put the replacement back in place. Checked to see that the new motor and fan, before final hook up, had no issues. That was a success. How
... Read more
ever, when I put the parts in place, I had some significant vibrations. By taking things apart and re-doing the install, the vibrations went away. However, the final install, even if quiet, did not work. Apparently the condenser was kaput. No cooling after all the adjustments. We gave up and are replacing the fridge.
Read less
Was this helpful?
Thank you for voting!
Oven light bulb went dark; it needed replacing
10 of 17 people
found this instruction helpful.
-
Lise from CEDAR GROVE, NJ
- Very Easy
- Less than 15 mins
Twisted replacement bulb into place easily. Let there be light!
Was this helpful?
Thank you for voting!
fan motor worn out
7 of 9 people
found this instruction helpful.
-
Richard from Norman, OK
- A Bit Difficult
- 15 - 30 mins
-
Screw drivers
Removed the old and installed the new. Electrical plug/socket made connection easy. Biggest problem is working space in freezer side of a side by side with the fan in the back. If I can do it anyone can.
Was this helpful?
Thank you for voting!
Coils freezing up and refrigerator would get warm
6 of 7 people
found this instruction helpful.
-
Richard from Scranton, KS
- Easy
- 15 - 30 mins
-
Nutdriver
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ... Read more ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ... Read more ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
Read less
Was this helpful?
Thank you for voting!
Freezer frosted up
6 of 7 people
found this instruction helpful.
-
Gregg from Mohnton, PA
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench set
Removed old thermostat and replaced. really easy.
Was this helpful?
Thank you for voting!
Freezer was getting a build up of frost on the condenser and wasn't cooling.
5 of 5 people
found this instruction helpful.
-
Arthur from Lithonia, GA
- Really Easy
- 15 - 30 mins
-
Nutdriver
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested
... Read more
good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
Read less
Was this helpful?
Thank you for voting!
coils freezing refrigerator not cooling
7 of 11 people
found this instruction helpful.
-
Else from Plant City, FL
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
The defrost timer is located under the freezer side behind the lower plastic cover. Very simple, just 2 screws and a plug, and your done.
The thermostat requires removing the lower drawers in the freezer and unscrew the back side of the rails and let them hang over to get access to the lower cover on the back of the freezer. On ... Read more ce the panel is off you will be able to see the thermostat. From there you just remove the thermostat from the clip, cut the 2 wires, splice in the new thermostat and re install using the new clip and your done!!
This was my first time and it was really simple. I had a local repair shop quote me $375.00 . I did it myself for under 50.00 shipped to my door..
The thermostat requires removing the lower drawers in the freezer and unscrew the back side of the rails and let them hang over to get access to the lower cover on the back of the freezer. On ... Read more ce the panel is off you will be able to see the thermostat. From there you just remove the thermostat from the clip, cut the 2 wires, splice in the new thermostat and re install using the new clip and your done!!
This was my first time and it was really simple. I had a local repair shop quote me $375.00 . I did it myself for under 50.00 shipped to my door..
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
refrigerator stopped cooling
11 of 23 people
found this instruction helpful.
-
Lisa from Los Angeles, CA
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
After the refrigerator stopped cooling, we determined that the problem was in the compressor area. we used a screwdriver to get the cover off and then vice grips to get the actual pieces out (start relay & overload)--they broke, but they were already broken). We went to the Home Depot site to purchase the parts, but found PartSelect to b
... Read more
e much less expensive. Put the parts in when they came a few days later and it worked! thank you PartSelect!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!