110840 Kenmore Washer - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Hot water was not flowing
0 of 1 people
found this instruction helpful.
-
Greg from Lafayette, CA
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set, Wrench set
Removed backing and hoses and replaced the water inlet valve.
Was this helpful?
Thank you for voting!
No hot water
0 of 1 people
found this instruction helpful.
-
Alan from Brooklyn, NY
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
I followed the great step by step video instructions that you provided. The only difficulty was getting the plugs off the Water Inlet Valve. I had to use pliers (gently) to pull the two plugs off. I would highly recommend PartSelect to my friends.
Was this helpful?
Thank you for voting!
Cold water was leaking into tub constantly and hot water took forever to fill.
0 of 1 people
found this instruction helpful.
-
Judith from St. Louis, MO
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
With the help of reading about other individuals and their problem, I was able to replace the water inlet valve in less than 30 minutes. Unscrewed two screws on top to reveal the flat springs. Popped the springs and released the back of the washer. Removed the old part and replaced with new. A lot easier than I thought.
Was this helpful?
Thank you for voting!
No hot water & very little cold water
0 of 1 people
found this instruction helpful.
-
John from Royse City, TX
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
As I tore my ACL, my wife actually did the actual repair while I talked her through it. The video on your website was such a great help. Our repair went exactly as depicted.
Was this helpful?
Thank you for voting!
Won't stop filling with water
0 of 1 people
found this instruction helpful.
-
Walter from Palmerton, PA
- Really Easy
- 15 - 30 mins
-
Nutdriver
Loosing back cover to reach in and remove valve
Was this helpful?
Thank you for voting!
No cold water / inlet valve not working
0 of 1 people
found this instruction helpful.
-
Barry from Logan, AL
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
I diagnosed by reversing the plugs on the hot/cold valves. I then removed the valve , cleaned it up and sprayed the electrical contacts with (Corrosion Block) and re-assembled. It still only had hot water. Ordered part, received part next day. When I went to install it I discovered that the (Corrosion Block) had penatrated and all was w
... Read more
orking! So now I have a spare valve.
Read less
Was this helpful?
Thank you for voting!
Hot water not going into machine
0 of 1 people
found this instruction helpful.
-
Katherine from Greenville, NY
- Really Easy
- 15 - 30 mins
-
Screw drivers
Opened back panel and replaced valve - very easy
Was this helpful?
Thank you for voting!
Water inlet valve would not shut off on cold side.
0 of 1 people
found this instruction helpful.
-
George from Edgerton, WI
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
I removed the faulty valve after unplugging the AC cord. Two screws, the two water hoses were removed, and the electrical connections were unplugged. The old valve could then be rotated so that the clamp on the fill tube could be loosened and the tube pulled off the valve.
The new valve body seemed to be an exact replacement, but t ... Read more he mounting bracked was slightly different and required drilling two new screw-mounting holes; an easy job.
Before securing the mounting plate to the machine, the fill tube and clamp were reattached, and the electrical connectors plugged in. After connecting the supply hoses and plugging in the AC cord, the machine filled with water properly and everything seemed to be back to normal.
I might have been able to use the original mounting plate, but it had been taken to a different location which was too far away to easily retrieve.
The new valve body seemed to be an exact replacement, but t ... Read more he mounting bracked was slightly different and required drilling two new screw-mounting holes; an easy job.
Before securing the mounting plate to the machine, the fill tube and clamp were reattached, and the electrical connectors plugged in. After connecting the supply hoses and plugging in the AC cord, the machine filled with water properly and everything seemed to be back to normal.
I might have been able to use the original mounting plate, but it had been taken to a different location which was too far away to easily retrieve.
Read less
Was this helpful?
Thank you for voting!
Had no hot water flowing into the washer.
0 of 1 people
found this instruction helpful.
-
Valan from Arlington, TX
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
I just followed the instructions from a previous customer. Worked perfectly.
Was this helpful?
Thank you for voting!
Dryer would not activate
2 of 7 people
found this instruction helpful.
-
Andris from Sands Point, NY
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers, Socket set
>removed 2 screws connecting the vent filter to the top lid of the unit (just in front of removable filter).
>Losing two screws at the back of the machine, just below control panel to allow free movement of the top lid on its hinges.
>Raise top lid & supported open.
>Now have free access to door switch (inside , front right ... Read more fastened to front panel)
>removed the old switch
>fasten new switch (required new wire connector which was supplied with package) to existing wiring and replaced.
>Works perfectly!
>Losing two screws at the back of the machine, just below control panel to allow free movement of the top lid on its hinges.
>Raise top lid & supported open.
>Now have free access to door switch (inside , front right ... Read more fastened to front panel)
>removed the old switch
>fasten new switch (required new wire connector which was supplied with package) to existing wiring and replaced.
>Works perfectly!
Read less
Was this helpful?
Thank you for voting!
water inlet valve would not shut off because of warn out part
0 of 1 people
found this instruction helpful.
-
walter from palmetto, FL
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers, Socket set
Take top of washing machine off. Turn spikets off and remove hot and cold inlet hoses. Remove one screw holding part in place. Reach from front and take valve out. Unplug wiring harnesses. Reinstall the same way I took it off.
Was this helpful?
Thank you for voting!
Wasn't flowing cold water effectively
0 of 1 people
found this instruction helpful.
-
Jason from Sterling, VA
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
To Whom It May Concern:
I had issues with my washer not flowing cold water very efficiently.
I was convinced I was going to have to spend at least $200 to get
someone to fix it or buy a new unit. My friend showed me your site
and videos. I quickly found the part I needed, had full confidence
that my proble ... Read more m would be solved with that part and that I'd be able to
do it myself. I ordered the part yesterday, got it today, and
installed it in under 15 minutes (thanks to the excellent video).
What an amazing customer experience!!
This is the greatest buying process I've every had with an Internet
purchase....hands down!! You saved me a couple hundred bucks and made
it fun and easy for me to fix myself. You guys are the best. No
doubt about it.
Thank you so much, Jason
I had issues with my washer not flowing cold water very efficiently.
I was convinced I was going to have to spend at least $200 to get
someone to fix it or buy a new unit. My friend showed me your site
and videos. I quickly found the part I needed, had full confidence
that my proble ... Read more m would be solved with that part and that I'd be able to
do it myself. I ordered the part yesterday, got it today, and
installed it in under 15 minutes (thanks to the excellent video).
What an amazing customer experience!!
This is the greatest buying process I've every had with an Internet
purchase....hands down!! You saved me a couple hundred bucks and made
it fun and easy for me to fix myself. You guys are the best. No
doubt about it.
Thank you so much, Jason
Read less
Was this helpful?
Thank you for voting!
Water would not shut off after filling for cycles
0 of 1 people
found this instruction helpful.
-
Michael from Shipshewana, IN
- Easy
- Less than 15 mins
-
Nutdriver, Pliers, Screw drivers
I found the helpful video, after a bit of a struggle removing rear panel from machine!! I determined the problem of being the water inlet valve from prior troubles on a machine.
I removed the screws from bottom of rear panel,then the Phillips screws from the back of control panel. bumping the control panel towards the front of the ... Read more machine dislodges it from it's slots. the control then tilts back on plastic hinges, exposing the clips that hold on the rear panel.Those clips are pried up and removed. dis connect the wire harness to control panel. A similar screw as the first removed at bottom hold the inlet valve on the panel.. two simple wire terminals are pulled off as well as a small water line. I did not remove the entire cabinet front as shown in the video as space did not permit it. Still easily reached. the reverse was done to install. The machines are heavy, do get help there.
I did not have it. Be certain to shut off water supply before beginning. Also, I forgot to reconnect the wire harness to control panel. you wont,RIGHT.
I removed the screws from bottom of rear panel,then the Phillips screws from the back of control panel. bumping the control panel towards the front of the ... Read more machine dislodges it from it's slots. the control then tilts back on plastic hinges, exposing the clips that hold on the rear panel.Those clips are pried up and removed. dis connect the wire harness to control panel. A similar screw as the first removed at bottom hold the inlet valve on the panel.. two simple wire terminals are pulled off as well as a small water line. I did not remove the entire cabinet front as shown in the video as space did not permit it. Still easily reached. the reverse was done to install. The machines are heavy, do get help there.
I did not have it. Be certain to shut off water supply before beginning. Also, I forgot to reconnect the wire harness to control panel. you wont,RIGHT.
Read less
Was this helpful?
Thank you for voting!
Leaky Inlet Valve
0 of 1 people
found this instruction helpful.
-
Joseph from Oakland, CA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
This is a very easy repair. After shutting off the water, removing the feed lines, and of course unplugging the electricity, all I had to do was: 1. remove two screws 2. flip the control panel up 3.unplug a wiring connection 4. pop two clips that hold the housing to the back 5. lean housing forward 6.unplug wiring at valve 7. remove fill
... Read more
hose 8. remove two screws. 9. toss old valve in the recycling bin (or trash depending on your area) 10. Reverse procedure using new valve. 11. wash clothes.
Read less
Was this helpful?
Thank you for voting!
Cracked / leaking water valve
0 of 1 people
found this instruction helpful.
-
Robert from Roswell, NM
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Rmoved top, removed back, replaced valve.
Was this helpful?
Thank you for voting!