The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Parts Used:
Condenser Fan Motor Kit
  • Bob from Hesston, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old resevoir needed to be replaced
The repair was incredibly easy -
1. Turn off the water at the water line for the fridge
2. Disconnect the pressure fittings for both lines running to the resevoir.
3. Remove the old resevoir
4. Install the new resevoir and run the lines back to the orginal fittings.
5. Reconnect the fittings, turn on water.
6. Drink water!
Parts Used:
Water Dispenser Reservoir Tubing
  • Fred from Martinsburg, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
34 of 66 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker water outlet freezes and prevents flow
Get refrigerator out away from the wall. Disconnect from power. Loosen 3 and remove 3 or 4 screws to uncover fan, compressor and water inlet valve (WIV). By hand remove plastic hoses that feed the water dispenser and ice maker feed. Unscrew 2 screws that hold WIV her you need the Spring U Joint (SUJ) or equivalent. Pull wires and make mental note or picture the way they fit. They retain the memory the way they came out. With adjustable or wrench remove tube that comes from the filter. Remover black rubber protector from WIV. Install the last hose you removed. Tighten by hand and finish with the wrench used to remove it. Don't over tighten. Maybe 3/4 turn or less after hand tight will do. The difficult part is to re-install the screws that hold the WIV in place, again you need the SUJ. The alternative would be to empty the shelves from anything that will spill or break and have someone tilt the refrigerator and access from below. I used the 1st method as I didn't have the extra help. Install the water dispenser hose (by hand), blow compressed air to the ice dispenser hose to clear the ice. There is another plastic hose just above and behind the dispenser which must be removed to clear the ice that is being blown. After the ice is clear re-install the one in the freezer. That one is just pressure held be careful not to break when replacing it. Re-install by hand the ice dispenser hose to the WIV. Replace the cardboard cover that was 1st removed to access the components. Power the refrigerator and you are ready to make fresh ice. My ice maker lever was stuck at 1st. I released pressure from the metal wire lever and wiggled up and down several times to loosen up.
Parts Used:
Dual Outlet Valve Kit
  • Alexander from Miami, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set, Wrench (Adjustable), Wrench set
20 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Parts Used:
Water Tube Kit
  • jesse from hacienda heights, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
21 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Parts Used:
Refrigerator Door Switch
  • bill from escondido, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Parts Used:
Condenser Fan Motor Kit
  • David from Cedarville, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Ice maker would not work.
We rolled the refrigerator out away from the wall and it was obvious where the break was located. We took out the old water spout for the ice maker and replaced the tube and the tubing from the solenoid. We turned it on and soon we had water dripping everywhere. We unloaded and defrosted the freezer which got all of the remaining ice that was stuck in there. We put everything back together. I read in some instructions in the manual that it might take 24 hours for the ice maker to reprogram itself and start producing ice. I was only about 12 hours and we had ice again and everything worked well. You really do not have to disconnect the water from the main line, the solinoid controls that part of operation and turns the water off until the ice trays are free and clear.

JLB
Parts Used:
Water Tube Kit Ice Maker Water Fill Tube Kit
  • Jerry from Boulder, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
22 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My Fan in the Freezer was making a loud noise
I went on the web to search for parts, did my screening of companies, and chose Partselect.com
They gave me accurate information, very nice, and double checked the part numbers, and the latest replacement part. I received it in a couple of days, followed the directions, and it's working just fine! I saved a lot of money through Partselect, instead of buying a new refrigerator.
NICE JOB Partselect!!
Thanks,
Michael
Parts Used:
Evaporator Fan Motor Kit
  • Michael from Imperial, MO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dripping from door dispenser
The part received was a straight replacement part - no modification required, just a simple remove and replace. This made the job really easy. Used the socket set to lower the front wheels to move the refrigerator, the nutdriver to remove the back cover and the valve, and the adjustable wrench to remove the water line. I had to cut the supply line tubing because the ferrule was too far up the line to make a good seal (minor leak quickly corrected with parts available in the kit - nice touch!) What took the most time was cleaning the coils and lint, etc. - hey I hadn't moved the unit in years! - but I did not include the 45-60 minutes this took in the repair time. Directions supplied were clear and easy to follow - but in my case I could have done the job without them - easy to see what needed to be done, but the stated precautions were nice.
Parts Used:
Dual Outlet Valve Kit
  • Charles from Sacramento, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set, Wrench (Adjustable)
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to icemaker
The replacement valve was identical to the old one, so I didn't have to use any of the adapter parts sent with the new valve. This made the installation rather simple. After removing the back cover on the lower part of the refrigerator, I turned off the water and electrical supplies, and removed the water supply line to the valve. Then I removed the two screws securing the valve to the refrigerator. Next, I removed the two electrical connections from the valve, and unscrewed the plastic nuts holding the tubing to the valve. I didn't have to use a wrench to do this as they were hand tight, so when I attached the tubing to the new valve I tightened the nuts hand tight. This seemed to be sufficient and avoided the possibility of stripping the nuts. After checking for leaks, I attached the electrical connections and secured the new valve to the refrigerator. Then I attached the water supply line, but before replacing the back cover, I turned on the refrigerator, and let it cycle through it's first load of ice.
Parts Used:
Dual Outlet Valve Kit
  • Walter from Willis, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken gooseneck on fill tube
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.

Shut off water supply line, and turn off ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.

Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Parts Used:
Ice Maker Water Fill Tube Kit
  • Thomas from Brunswick, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Parts Used:
Light Socket Kit
  • martin l. from JACKSONVILLE,, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL