Dryer made loud intermittant humming sound after 20-30 minutes of use
1 of 3 people
found this instruction helpful.
-
Gregory from Virginia Beach, VA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
Unplug Dryer. Remove 2 5/16in hex screws from lower panel and remove panel.Remove 3 5/16in hex screws attaching lint duct. Remove 8 1/4in hex screws attaching blower housing. Remove 2 1/4 hex screws attaching thermostat to blower housing. Using adj. wrench on back of motor shaft nut to hold, loosen fan assy. w/ 7/8in socket. Remove 3 5/16
... Read more
in hex screws holding fan housing to motor mount. Remove 2 5/16in hex screws holding housing and motor mount to base floor. Push belt pulley wheel up enough to loosen belt and take off rear motor pulley. Motor w/mount can be slid out bottom for replacement [wires are layed toward front].Using 6in flat tip screw driver press down to unlock front & back motor bushing holddown clamps. Pinch electrical wire connector ends to pull off old motor. Remove and Install new motor, reversing steps. Belt replacement [suggested w/new motor] requires removal of 2 5/16in screws to lift/remove door w/front panel [disconnect door switch wires upper right rear corner].Remove 4 5/16 screws holding front bulkhead. Once bulkhead is pulled up and off, allow front end of drum to sag and rest IN PLACE [removal not required to slip old belt off and install new belt]. Note belt location point around drum. Slide new belt on. Reinstall bulkhead and panel/door [Don't forget door swich wires]. Adjust belt into position and push spring-held belt pully up to allow looping of new belt around rear motor belt pulley. Complete w/hand turning of drum to ensure belt is aligned and feeding properly. Reinstall lower fan housing/covers/thermostat,etc removed for motor installation.
Read less
Was this helpful?
Thank you for voting!
Frost in bottom freezer, freezer 8%, ice maker works
0 of 1 people
found this instruction helpful.
-
Richard from Smyrna, GA
- Easy
- 15 - 30 mins
replaced electric control board, defrost for six hours. next day (24 hours) same problem, [email protected]
Was this helpful?
Thank you for voting!
light staying on
0 of 1 people
found this instruction helpful.
-
Cecelia from Beaver Dam, WI
- Easy
- 15 - 30 mins
-
Screw drivers
A very cold and brittle switch in a 17 year old fridge. Used screwdrivers to pry out with some resistance Had to cut the molded plug in half and split wires, because replacement contacts were farther apart than the original. End result, works great.
Was this helpful?
Thank you for voting!
Replace Bad Switch
0 of 1 people
found this instruction helpful.
-
carlos from haverstraw, NY
- Easy
- Less than 15 mins
-
Pliers, Screw drivers
Pry old switch and pull out. Disconect two wires. Put two wires on new switch, must be inserted right and connections not loose. Put switch in, making shure wies do not come off and snap in place
Was this helpful?
Thank you for voting!
19 year old light switch broke
0 of 1 people
found this instruction helpful.
-
Fred from Watertown, NY
- Really Easy
- Less than 15 mins
Great service. Unpluged old switch and pluged in new one. Works great
Was this helpful?
Thank you for voting!
Switch Controlling Light When Door Open Was Briken
0 of 1 people
found this instruction helpful.
-
WES from SPRINGVILLE, AL
- Really Easy
- Less than 15 mins
Poped ou the old switch, connected new switch and pushed back into socket.
Was this helpful?
Thank you for voting!
Door Light switch cracked Mounting
0 of 1 people
found this instruction helpful.
-
Paul from Hinsdale, IL
- Really Easy
- Less than 15 mins
-
Screw drivers
I noticed that the refrigerator was having trouble maintaining temperature. Thought it might be time for new one until I found out that a new frig was $5k to $7K. Just happened to notice that the light switch didn't look quite right (was not sitting sqaure to the door). Once I pressed it it came loose. I then realized the the lights we
... Read more
re staying on (50 watts of heating). Replaced the switch and the frig started working like new.
Read less
Was this helpful?
Thank you for voting!
Lights didn't always come on when was opened
0 of 1 people
found this instruction helpful.
-
Gary from Jenkintown, PA
- Really Easy
- Less than 15 mins
-
Screw drivers
Used a screwdriver to pry loose the old switch, swapped wires to the new switch and pushed it into the opening. Took about 2 minutes.
Was this helpful?
Thank you for voting!
Broken light switch
0 of 1 people
found this instruction helpful.
-
George from North Scituate, RI
- Really Easy
- Less than 15 mins
-
Screw drivers
Part was easy to order, delivered quickly, installation very easy. Just unplug the unit, pop out the old swich using a screwdriver, disconnect and reconnect leads and pop switch back in. Definitely recommend that you can do it too.
Was this helpful?
Thank you for voting!
old switch left freezer bulb always-on
0 of 1 people
found this instruction helpful.
-
JONATHAN from ELKINS PARK, PA
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Unplug appliance. Socket wrench to unscrew two screws. Module drops down. disconnected two press-on wires by prying off with screwdriver. Removed old switch. Press-fit new switch. Reconnected two wires (color coded). Screwed module back in place. Plug in appliance.
Was this helpful?
Thank you for voting!
light would work intermitently
0 of 1 people
found this instruction helpful.
-
Gregory from middle island, NY
- Easy
- Less than 15 mins
-
Screw drivers
removed the 2 screws that held the panel in place, had to reach up and push on locking tabs to lower trhe front of the panel. was able to then push on the locking tab of the switch to release it. removed the wires, replaced them onto the new switch, and snapped the switch into place. the rest was reverse of the uninstall process.
Was this helpful?
Thank you for voting!
Light switch broken
0 of 1 people
found this instruction helpful.
-
Keith from Racine, WI
- Really Easy
- Less than 15 mins
I used a knife blade to slip under the edge of old switch to pray it out of the hole it was inserted into, switched the wires and replaced the new switch into the same hole. It took about five minutes!
Was this helpful?
Thank you for voting!
Internal light did not come on each time the door was opened.
0 of 1 people
found this instruction helpful.
-
John from Jefferson Hills, PA
- Really Easy
- Less than 15 mins
After disconnecting the electricity. I followed the instructions as indicated in the "HOW TO" article on the website. I used a steel putty knife and pried the light switch out of its retaining hole. I worked the right side the most since this is the side with the retaining clip. After I removed the switch I transferred the two electrical
... Read more
outlets to the new switch and easily snapped it into place. Engaged the electric power and tested the switch.
Read less
Was this helpful?
Thank you for voting!
rocker switch broke off
0 of 1 people
found this instruction helpful.
-
STANLEY from OAKLAND, NJ
- Really Easy
- Less than 15 mins
-
Screw drivers
disconnected el. power to fridge. pried out broken switch with small screwdriner and pulled out w/water pump pliers. installed new switch and pressed into opening.
Was this helpful?
Thank you for voting!
light switch would not work
0 of 2 people
found this instruction helpful.
-
Joseph from Destin, FL
- Really Easy
- Less than 15 mins
Popped the old one out with a kitchen knife and popped the new one back in. It tool less than 15 seconds!!
Was this helpful?
Thank you for voting!