PBA MAIN

 Fits your GFSF6KKYAWW Refrigerator!
$499.14
  Special Order
 Fits your GFSF6KKYAWW Refrigerator!
PartSelect Number PS2371143
Manufacturer Part Number WR55X10955
Manufactured by GE
Troubleshooting
This part works with the following products:
Refrigerator.
This part works with the following products:
General Electric.
Back to Top
Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

2 questions answered by our experts.
  • 1
Sort by:
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Cleveland
November 15, 2019
Do this model have self test mode if so what are the steps?
For model number GFSS6KKYASS
PartSelect logo
Hello Clevland, Thank you for the question. To enter Self Diagnostic mode, both temperature control panel displays must be illuminated. A display can be illuminated by pressing an adjacent temperature adjustment button. When both displays are illuminated, set the freezer and refrigerator temperature settings to 5. Simultaneously press and hold all 4 temperature adjustment buttons for approximately 3 seconds. A flashing 0 in the refrigerator and freezer displays will indicate that the refrigerator is in Self Diagnostic mode. Use the freezer temperature adjustment buttons to enter the test code number in the freezer display. Use the refrigerator temperature adjustment buttons to enter the test code number in the refrigerator display. When a test code has been entered, the displays will flash to confirm the test. Press the HOLD button for 3 seconds to begin the test. Enter defrost: Freezer, Fridge. . 1. . . 4. If the cabinet is not cold when executed, this mode may execute extremely fast. The refrigerator will return to normal operation on its own. When testing has been completed, do one of the following things: Enter code 1 5 to completely reset the system. Enter code 1 6 to exit diagnostic mode. The temperature control panel is reset automatically. Unplug the refrigerator for at least 10 seconds. Test mode will terminate when the refrigerator is plugged back in. Test mode will terminate automatically after 15 minutes of inactivity. Hope this helps!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Cleveland
November 19, 2019
Hello my fz not getting cold the fr is working fine 38 degree.The fz wont go lower then 68degree.The condensor coil is clean all the fan or operating.I got some instruction on how to put in self diagnostic mode wasn't able to.Can you email the instruction again?I check the tem sensor the defrost sensor all test good.Is their a way to trouble shoot the main pc board for voltage?The model gfss6kkyass.Thanks .
For model number GFSS6kkyass
PartSelect logo
Hello Cleveland and thanks for writing. for your convenience, we have attached the link to the manual. We hope this helps. Please contact us anytime. https://partselectcom.azureedge.net/assets/manuals/09097B3149A66AB36F245F2E0E31D140743400BE.pdf Self Diagnostics To enter Self Diagnostic mode, both temperature control panel displays must be illuminated. A display can be illuminated by pressing an adjacent temperature adjustment button. When both displays are illuminated, set the freezer and refrigerator temperature settings to 5. Simultaneously press and hold all 4 temperature adjustment buttons for approximately 3 seconds. A flashing 0 in the refrigerator and freezer displays will indicate that the refrigerator is in Self Diagnostic mode. Use the freezer temperature adjustment buttons to enter the test code number in the freezer display. Use the refrigerator temperature adjustment buttons to enter the test code number in the refrigerator display. When a test code has been entered, the displays will flash to confirm the test. Press the HOLD button for 3 seconds to begin the test. Enter defrost: Freezer . . . . . Fridge . . 1. . . . . . . . . . 4 If the cabinet is not cold when executed, this mode may execute extremely fast. The refrigerator will return to normal operation on its own. When testing has been completed, do one of the following things: • Enter code 1 5 to completely reset the system. • Enter code 1 6 to exit diagnostic mode. The temperature control panel is reset automatically. • Unplug the refrigerator for at least 10 seconds. Test mode will terminate when the refrigerator is plugged back in. Test mode will terminate automatically after 15 minutes of inactivity.

Was this helpful?
Thank you for voting!
  • 1
Related Parts
Model Cross Reference
This part works with the following models:
PartSelect Number: PS2371143
Manufacturer Part Number: WR55X10955
Brand
Model Number
Description
General Electric
GFSF6KKYABB
Refrigerator
General Electric
GFSF6KKYAWW
Refrigerator
General Electric
GFSL6KKYALS
Refrigerator
General Electric
GFSS6KKYASS
Refrigerator
Customer Service Representative

Get in touch, we're here to help!

Monday to Saturday
8am - 9pm EST

Contact Customer Service